Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid L1 rank competitive and reasonable during Scrutiny | |
| 2 | L2₹75.3 L+₹1.5 L (2.00%)Rejected-AOC | L2 | Rejected-AOC Not lowest | |
| 3 | Rejected-Technical HIG 40 TYPE B DEV PRAYAGAM ADA COLONY JHALWA PRAYAGRAJ U P 211015 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211015 | - | Rejected-Technical Being two class below |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
4 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
CWE AF BAMRAULI ALLAHABAD
IMPROVEMENT TO SEWAGE LINE AT SOUTH CAMP AND NORTH CAMP AT AIRFORCE STATION BAMRAULI
2022_MES_565758_1
87214/E8
Open Tender
Civil Works - Others
Item Rate
182 days
BAMRAULI ALLAHABAD
Class B Category a ii and other criteria as per NIT
8 documents required · 8 mandatory
₹1,000
GE AF BAMRAULI
₹1.8 L
Yes
4 Mar 2023
28 Nov 2022
11 Jan 2023
28 Nov 2022
4 Jan 2023
21 Dec 2022
28 Nov 2022 - 8 Dec 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantaling of Stone slabs and tiles laid bedded and pointed in any mortor or of any description or thickness in floors, aprons etc.
Demolition of PCC of any description and any position complete all as specified and directed.
Demolition of precast RCC manhole covers of any size complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, Arches etc and removal of debrishes from site complete all as specified and directed.
Taking down cement plaster of walls, partitions, ceilings,etc, and include for all necessary lowering, etc removal of rubbish off the premises, removal and depositing serviceable materials where directed and leaving the work clear of any plastering and all as specified.
Dismantling of mild steel or structural steel work including doors, gates, but excluding framed truss and dismantling of CI work and removing complete all as specified and directed.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified.
Site clearance as in soft/loose soil complete all as specified.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep in soft/ loose soil and getting out all as specified.
Excavation over area n.exc 1.5m deep & getting out in hard and dense soil and getting out all as specified.
Ditto all as per item above here-in-before but exc 1.5 m and not exc 3.0m deep.
Ditto all as per item above here-in-before but exc 3.0 m and not exc 4.50m deep.
Ditto all as per item above here-in-before but exc 4.50 m and not exc 6.0m deep.
Ditto all as per item above here-in-before but exc 6.0 m and not exc 7.5 m deep.
Excavation in trenches in soft/loose soil not exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation etc or for shafts wells manholes etc n. exc in 10 sqm on plan and getting out complete all as specified and directed.
Excavation in trenches in hard/dense soil not exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation etc or for shafts wells manholes etc n. exc in 10 sqm on plan and getting out complete all as specified and directed.
Ditto all as per item above here-in-before but exceeding 1.5 metre and not exceeding 3.00 metre in depth.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level complete all as specified and directed.
Ditto all as per item above here-in-before but exceeding 100 metre not exceeding 150 metre .
Ditto all as per item above here-in-before but exceeding 250 metre not exceeding 500 metre .
M&L for Hardcore of broken stones of guage not exceeding 63mm deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M & L for PCC type D2 1:4:8 using 40 mm graded crushed stone aggregates in foundation filling and mass concrete complete all as spd.
M & L for 50 mm thick PCC 1:3:6 type C1 (using 20 mm graded aggregate) as in plinth protection laid to a slope of 1:12 and finishing cement concrete surfaces even and smooth without using extra cement including all necessary form work to divide the area in panels and finishing exposed edges fair or rounding or chamfering of exposed edges where directed complete all as specified and as directed.
M & L PCC Type B-1, 1:2:4 (using 20mm graded stone aggregate) as in foundations,filling mass concrete complete all as specified and as directed.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregates as in filling on holes in walls, bed block for inserting hold fast and coping slightly rounded or chamferred angles and throating including necessary form work complete all as specified and directed.
M & L Pre - cast reinforced cement concrete (1:2:4) type B-1 using( 20 mm graded crushed stone aggregate) as in cover slabs chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc set in CM (1:6) etc complete all as specified and directed.
M & L for plain cement concrete 1:3:6 type C-2 ( using 40 mm graded stone aggregate) as in bed of drain & all as specified and directed.
M & L for PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in surface channel and drain finished surface even & fair complete all as specified and directed.
M & L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred stopped ends complete all as specified and directed.
Add or deduct from Item above here-in-before for each 25mm girth or part there or over or under 30cm.
M & L Pre - cast reinforced cement concrete as in cover slab (1:2:4) type B-1 using( 20 mm graded crushed stone aggregate) as in manhole cover of any size including RCC ring/Frame and MS frame set in CM (1:4) etc complete all as specified and directed.
M & L 150 mm thick PCC (1:2:4) Type-B2, 40mm graded aggregate in foundation filling and mass concrete complete all as specified and directed.
M & L 100 mm thick PCC (1:4:8) Type-D2, 40mm graded aggregate in foundation filling and mass concrete complete all as specified and directed.
M & L for brick work with sub class ‘B’ bricks having crushing strength not less than 75 Kg/Sqm, straight or curved on plan exc 6 M mean radius half brick thick wall built in CM (1:4) complete all as specified and directed.
M & L for Brick work with old size bricks having crushing strength not less than 75 Kg/Sqm, straight or curved on plan exceeding 6 m mean radius with old size bricks built in cement mortar 1 : 4 complete all as specified.
M & L for RCC Nominal mix 1:2:4 Type B1 using 20mm aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter of fair finished surfaces complete all as specified
Form work to to edge of concrete flats etc exc 5 cm but not exc 10 cm wide/thick for fair finished surface of concrete all as spd.
M & L for MS TMT bar 10mm dia and over cut to length, bent to shape required including cracking, bending, spirally for hooping for column, hooking end and binding with including miled steel wire canconlled not less than 0.9mm dia or securing clips.
M & L for MS TMT bar 8 mm dia cut to length, bent to shape required including cracking, bending, spirally for hooping for column, hooking end and binding with including miled steel wire canconlled not less than 0.9mm dia or securing clips.
S & F for 1 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type and all as specified.
S & F Framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar workconforming to Fe.290.Gde-E-165
S & F Oil and Grease trap of size 900 x 900 x 900 mm, body material Stainless Steel Gde-304, thickness 1.8 mm, basket size 325 x 325 mm & trap size 75 mm ,inlet and outlet size 75mmalongwith its connection accessories and making good etc complete all as specified and directed.
Rendering 15mm thick in CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement including mixing of integral liquid water proofing admixture in the proportion as mentioned in manufacture's instructions complete all as specified. ( Integral water proofing Admixture to be measured & paid for separately).
Rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified.
Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified.
M & L for 15 mm thick rendering in CM (1:4) on external surface other than fair faces of brick wall finished fair and even complete all as specified and directed.
Rendering 5 mm thick in CM 1:3 on ceiling fair faces of concrete surfaces finished finished fair and even complete all as specified.
Supply only Intergral water proofing compound.
M & L for three coats of white washing on newly prepared plstered surface of wall complete all as specified.
M & L for three coats of white washing on newly prepared plstered surface of ceiling complete all as specified.
M & L for preparation of new steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by the Engr-in-Charge.
M & L for preparation of old painted steel surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and directed by the Engr-in-Charge.
M & L for 110mm bore, PVC (SWR) pipes, single socket in any length, with rubber ring joints fixed on walls.
S & F PVC (SWR) bends radius 110 mm bore complete.
M & L for Road cutting of width n exc 1.50 Mtr and depth n exc 0.30 cm including its sub base or PCC etc complete all as specified and directed.
M & L for machine pressed precast concrete interlocking paver block of grey cement, rubber moulded, glossy finish and no pigment, any shape and size confirming to IS-15658-2006 of 80mm thickness, M-40 grade complete all as specified and directed.
M & L for 30 mm thick Sand filling under floor with approved sand including watering and consolidating complete
M & L for Chequered cement concrete tiles 20cmx20cmx25mm thick set and jointed in neat cement slurry including 15 mm thick screed in CM(1:6) and pointed in white or colour cement to match with grey cement and no pigment complete all as specified and directed.ected.
S & F RCC NP3 pipe dia 200 mm bore laid and jointed with collars in cement mortar complete all as specified.
M & L for PCC 1:3:6 type C2 using (40mm graded stone agg) to drain pipes 200 mm dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
S & F RCC NP3 pipe dia 150 mm bore laid and jointed with collars in cement mortar complete all as specified.
M & L for PCC 1:3:6 type C2 using (40mm graded stone agg) to drain pipes 150mm dia including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required 150mm Dia complete all as specified and directed. ( Note : Work in Foule Position )
S&F mild steel framed work such as grills, gratings etc with ends of bars shoulders or reveted, forged into spikes, framed guard bars, railings, ladders and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Cleaning of sewer line by mechanically by truck mounted sewage cleaning of underground sewage line for 150 mm bore pipe (including manholes by taking off manhole covers and re-fixing the same after cleaning) of any description underground any depth by removing any type of blockage including de-silting and de-chocking sewage line water sludge tank with wash down system / suck derrick arm hydrualically spring loaded rotary sliding vane compressor with V hose end section no 33 nozzle and strainer all as specified and as directed
Material and labour for cleaning of blockage manually by rodding, pumping etc and removing the deposited sludge/solid/liquid material, outside MOD land, complete all as directed from water closet (IWC/EWC) Trap & CI pipe line upto first manhole complete all as specified and directed.
Excavation in hard standing for crossing the road as per the authorized width for taking out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) complete all as specified and directed.
Taking out old unserveiceable underground CI/ DI/ GI pipes line of any size including making good to disturbed surfaces complete all as specified and directed.
Supply & laying in trenches ductile iron 150mm bore dia (DI) pipe with spigot and socketed ends centrifugally cast class 'K-7' in any length laid in trenches including taking out old unserviceable CI/DI pipe complete all as specified and directed.
Supply & laying in trenches ductile iron 200mm bore dia (DI) pipe with spigot and socketed ends centrifugally cast class 'K-7' in any length laid in trenches including taking out old unserviceable CI/DI pipe complete all as specified and directed.
Supply, fixing, jointing and testing in repair of cast iron sluice valve 150mm bore dia class I (ISI MARKED) PN-1.6 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve complete all as specified and directed.
Supply, fixing, jointing and testing in repair of cast iron sluice valve 200mm bore dia class I (ISI MARKED) PN-1.6 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve complete all as specified and directed.
M & L for upto 200mm bore DI fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed.
Dismantling old broken / damaged valve pit chamber of size 1050mm x 1050mm x 1050mm (internal dimention) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. (Ref Drg)
Supply and fix non clog submersible pump 2 HP with supper enamelled copper winding wire of existing size and quantity including insulating materials ie varnish , sleeves etc complete all as directed.
Supply and fix non clog submersible pump 5 HP with supper enamelled copper winding wire of existing size and quantity including insulating materials ie varnish , sleeves etc complete all as directed.
Supply and fix non clog submersible pump 15 HP with supper enamelled copper winding wire of existing size and quantity including insulating materials ie varnish , sleeves etc complete all as directed.
Material & Labour for pumping out sewage water mixed with sludge/ suspended sludge from Oxidation pond and water mixed sludge transported by filling in sever tank as well as suspended sludge transport/ shifting out side of MOD and deposited where directed at a place allotted by local muncial/ corporation including spreading of sufficient bleachig powder over the sluge to take all precuative health hazzored complete all as specified and directed.
Taking out old defective/ Serveiceable underground LT cable from trenches/floor/road/wall /pipe/pole of any type, size or description, complete all as specified & directed.
Relaying of LT underground cable of any type, size or description suitable for earthed system laid in duct/ trench/ along pole etc including making connection complete all as specified & directed
Supply, laying, testing and commissioning of LT UG cable, XLPE insulated, PVC sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 16 sqmm 4 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
All as item above here-in-before but of size 25 Sqmm 4core
M & L for sand in trenches and spreading in layers for cable cushioning all as specified and directed. Note: only consolidated thickness measured for measurement.
M & L for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable, complete all as directed.
M & L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long) seamless conforming to IS-2713 (Part-I & II) – 1980, welded and reduced section and longitudinal weld seam throughout entire length of pole including two coats of black bituminous paint externally upto planting depth and remaining exterior portion to pole with two coats of aluminium paint over a coat of red oxide primer complete including transporting the poles to planting point and providing three strips with light blue colour 300mm apart from plinth block and numbering of poles incl earthwork and PCC work complete all as specified and directed. Note:- (i) Earthwork shall be deemed to be included as specified. (ii) PCC work 1:4:8 Type D2 for base concrete of foundation shall be deemed to be included as specified.) (iii) PCC work 1:3:6 Type C1 for foundation shall be deemed to be included as specified.) (iv) PCC work 1:2:4 Type B1 for coping shall be deemed to be included as specified.)
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with dirver, lamp bracket with impact and corresion resistant inculding thermal management in multiple optics complete with IP 65/66 protection complete.
S & F cable Juction pole light box with connection terminals factory made of size not less than 205X255X112mm (Outside dimension) with IP 66 protection made out high quality of thermoplastic polycarbonate having 4 nos of 16/25 sqmm vibration proof terminals, weatherproof, fire resisance, cable entry there multiple knockout, outdoor type, extenally embeeded gasket technology not use any glu, gasket mareial should be polyurthene with 4 nos of external bracket made of polyucarbonate with fixing arrangement in junction box, with polycarbonate screw with 6 A MCB SP fixed on dinrail, MCB should be cover by transparnt cover and connection of street light using 2.5 sq mm PVC wire ,suitable thimble, lug ,the junction box should mount on pole with MS clamp complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing of automatic light switch using nature switch for automatic switching of street lights based on LUX level of natural light. the sensor (nature switch ) alongwith suitable power contractor , MCB and support terminals should be enclosed in pole / wall mountable enclosure made of rust proof , electric shock proof termite proof and FR grade special moulding compound junction box conforming to IP 54. The contactor , MCB and circuit wiring should suitable enough to take load of 1.2 KW equally distributed over 3-Phase (0.4KW /Phase). Contactor rating 40 Amps (SP 3 Nos) wiring main load with 6 sqmm copper conductor FR grade cable including dismantling old unsv one complete all as specified and directed.
DEORA ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .