Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | ₹1.7 Cr | L1 | Accepted-AOC Being L1 Bider |
| 2 | L2₹1.9 Cr+₹16.5 L (9.68%)Rejected-Finance | ₹1.9 Cr+₹16.5 L (9.68%) | L2 | Rejected-Finance Not being L1 Bidder |
| 3 | L3₹1.9 Cr+₹20.7 L (12.2%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | ₹1.9 Cr+₹20.7 L (12.2%) | L3 | Rejected-Finance Not being L1 Bidder |
| 4 | L4₹1.9 Cr+₹23.5 L (13.8%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | ₹1.9 Cr+₹23.5 L (13.8%) | L4 | Rejected-Finance Not being L1 Bidder |
| 5 | L5₹2.0 Cr+₹28.2 L (16.6%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | ₹2.0 Cr+₹28.2 L (16.6%) | L5 | Rejected-Finance Not being L1 Bidder |
Tender Value
₹2.9 Cr
EMD Value
₹3.6 L
Closing Date
11 Jan 2024, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVISION OF GEYSERS AND EXHAUST FANS IN SMQs ALONGWITH IMPROVEMENT IN EXTERNAL AND INTERNAL POWER SUPPLY AT AFS CHABUA (PHASE II)
2023_MES_631400_1
88660/CHAB/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF CHABUA
As per NIT Conditions
8 documents required · 8 mandatory
₹2,000
GE AF CHABUA
₹3.6 L
Yes
21 Mar 2024
6 Dec 2023
13 Jan 2024
6 Dec 2023
11 Jan 2024
4 Jan 2024
Amount
Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), complete all as specified and directed.
Taking up or down GI tubing of 15mm bore and connections, complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished fair and even, complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished fair and even mixed with water proofing compound as per manufacturer’s instruction, complete all as specified and directed. (Note : WPC shall be measured & paid separately).
Supply only water proofing compound approved quality, complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 350x250x7mm/450x350x7mm to 8mm thick in vertical surface set and jointed in neat cement slurry pointed with white or coloured cement to match over and including 10mm thick rendering in cement plaster 1:4, complete all as specified and directed.
S&F GI tubing of 15mm dia medium grade with all fitting and fixed complete to walIs and ceilings or laid in floors complete all as specified and directed.
S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat primer , complete all as specified and directed.
S&F 15mm bore fancy type chromium plated, concealed stop valves ,cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of oil distemper emulsion(Ist quality) of approved manufacturer over a coat of priming paint over, complete all as specified and directed
Cutting chases, pinning to facings where required and pointing for concealed water tubing etc. and making good, cutting not exc 10 cm girth and making good surfaces with cement mortar 1:3, complete all as specified and directed.
S & F 15mm bore, CP connection pipe 450mm long with nuts at both ends for hot and cold water line complete all as specified and directed.
S&F 2-in-1 brass chromium plated fancy type wall mixer, 15mm bore for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
M & L for mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F vertical type wall mounted storage water heater of capacity 25 Ltrs BEE 5 Star rated or minimum Standing Loss of 0.511 kWh , 240V, 50Hz with Maximum power consumption of 2 KW , dry powder fero glass line coating technology for inner tank with incoloy heating element , ABS outer body , 2 Nos PVC connection pipe with length of 450 mm length for hot and cold water supply with complete Accessories complete all as specified and as directed.
S & F single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
M&L for point wiring complete with 4 Sqmm, single core PVC insulated PVC unsheathed multi-stranded copper conductor FRLS cable 1100 volts grade laid/drawn through & including PVC casing and capping in walls/ceiling by means of PVC sleeve/dash fastener with cadmium plated iron screws all as per ISI including sunk type pressed steel terminal boxes for mounting, fittings like switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet top covers concealed in walls etc including 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as continuous earth wire to common earth and connecting to earth dolly of following including taking down of old one :- (a) outlet. 15 amps,independent,with cables 4 sq.mm size point controlled by one, one way switch. Note: - (i) Rate quoted shall include for cost of making MS box and concealed in wall including cutting and sinking of boxes and making good to the walls (No extra payment will be made for the same) (ii) Provision of blank plates as per site requirement (No extra payment will be made for the same)
M & L for concealed sub main wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLSH type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits medium grade not less than 20mm dia including 6 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down of old wiring complete all as specified and directed. Note :- (i) Two single cable for phase and neutral one single core green earth wire including one meter PVC conduit is measured as one unit. (ii) PVC conduit and its accessories is deemed to be included in this item rates. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
M&L for point wiring for One light point / one fan point controlled by one, one way switch complete as specified with 1100 V grade with 1.5 Sq mm single core PVC insulated unsheathed FRLScable, copper conductor multistranded passing through including concealed PVC conduit not less than 20 mm dia with concealed modular box suitable for logic modular switches , sockets , etc and logic modular white plates, surroundings of suitable size as required at site with PVC insulated FRLS unsheathed stranded copper conductor of size 1.5 sq mm as earth wire connected to common earth dully as specified complete all as specified and directed for the following:- Note: - (i) Rate quoted shall include for cost of making MS box and concealed in wall including cutting and sinking of boxes and making good to the walls (No extra payment will be made for the same) (ii) Provision of blank plates as per site requirement (No extra payment will be made for the same)
S & F in replacement for sheet metal enclosure MCB DB, 4 way with 200 amp rated bus bar VTPN double door DB (IP 43 & IK- 09 tested by ERDA & CPRI), designed and manufectured as per IS: 8623- 1 & 3, glow wire tested, colour RAL 9003 white with provision for surface and flush mounting, reversible door provsion, field fit-able key lock position, removable frame, centre plate and gland plate with incoming upto 160 Amp , 415 V, 4 Pole MCCB and 12 Nos outgoing MCB complete all as specified and as directed.
S & F in replacement MCCB 12 to 63 Amp, Ics=100%Icu, 25 kA breaking capacity, 4 Pole, hermal magnetic trip Unit, fixed thermal Fixed magnetic (FTFM), Ics=100% Icu, AC 415 volt ,50 HZ complete all as specified and directed.
S&F in replacement, sheet metal enclosures for SPN DBs when MCB to be used for 230 volts, 8 way earth and neutral link, IP 43 protection ,double door , concealed on wall, with 200 Amp rating copper bus bar, complete all as specified and as directed.
S & F in replacement MCB SP 6 to 32 Amps 230 Volt 'C' Curve, 10 kA complete all as specified and directed.
S & F in replacement MCB SPN 6 to 32 Amp with 10 kA breaking capacity, B curve, 230 Volt complete all as specified and as directed.
S & F switch piano flush type, single pole, one way, 5/6 Amp, 230 volts complete all as specified and directed.
S&F ceiling rose, 3 phase, phase/polycarbonate, isolated body,complete all as specified and directed.
S & F exhaust fan 225 mm sweep semi commercial metal double ball bearing and any type suitable for SP 230/250 V 50 Hz AC supply complete with louver shutters including 3 core flexible cable 900 RPM complete with mounting arrangment as per site requirement and connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed.
Cutting of hole through brick wall not exceeding 380mm thickness for fixing of new exhaust fan or enlarging the existing hole for fixing new exhaust fan , making good surfaces in cement mortar 1:4, finishing the surfaces with two coats of Oil bound distemper over a coat of primer complete all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized steel wire 4mm dia earthing lead upto 7.5m from testing point fixed by means of galvanized iron or steel bolts nuts check nuts and washers, GI earth wire protected by 15mm bore light grade galvanized iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore medium grade galvanized iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness)all around the earth electrode with concrete earth pit in PCC (1 : 3 : 6) type C-1, (using 20 mm graded stone aggregate) ,cast iron frame, 50mm thick pre-cast RCC M-25 design mix cover slab size 450x450x50 mm reinforced with 8mm dia TMT bar 10cm C/C and suitable handle of 10mm dia round bar and MS angle iron 50x50x6 mm frame including two coats of painting over a coat of red oxide primer to exposed steel surface including necessary excavation, earth work in soft/loose soil and disposal off spoil to a distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part I complete all as specified and as directed. [Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth leas and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) Excavation/earthwork is deemed to be included in the quoted rate.]
Supply, Installation, Testing and commissioning of Outdoor type, floor mounted step down transformer, 11 KV/433 Volts (at no load) AC, 3 phase, 50 Hz, 500 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural Air Natural, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN11 with neutral brought out on secondary side (LV side) and having tapings at + 2.5% & + 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree Celsius. The transformer shall bearing IS Mark of IS-1180 part 1 :2014 Level-2 (As per latest amendments of BEE/IS specifications) and BEE certified complete with all standard fittings and accessories gauges,and shall comprise of the following complete all as specified and ditected. (a) Three Nos porcelain bushing suitable for 11 KV on HV side complete with copper rods, nuts and washers. (b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out of incoming/outgoing cable for HT/LT side complete. (c) Oil conservator with filter type drain valve and oil level guage. (d) Dehydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent, thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Air release valve lug, Four plain solid cast steel detachable rollers. (f) One No 100 mm dia , dial type thermometer , vapour pressure type having range 0-120 degree celsiusn with metal guard having maximum perimeter reading temparature indicator with resisting.
Item No 32.00 contd......... (g) Two earthing terminals on tank to facilitate fixing of 50 x 6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (i) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (j) First fill of new and unused transformer oil, IS-335 marked filtered & tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. Note : (i) Poles their fixing /errcetion and structural steel work shall be measured and paid for seperately. (ii) Factory inspection at OEM premises shall be carried out by Rep of Accepting Officer. (iii) Pre-commissioning of TFR after installation shall be carried out by SEI/EI.
S&F Switch Air Break Gang operated tripple pole, mechanically operated, mounted on insulators and steel frame, with operating mechanism worked from ground level, current rating 200 Amps , 11000 volts including locking arrangment including 65mm pad locks with two keys complete with fuse mounts, fuse carriers and HT fuse element having suitable rating at 11KV and insulator suitable for 11KV, HT AC 50c/s and mounted on HT 11metre poles including 9 insulators and necessary connections complete all as specified and ditected.
S&F lightning arrestor expulsion type complete for 11000 volts with all fittings, transmission class, discharge capacity 65 kA all as specified and as directed (Set of three).
Supply, Laying and testing cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 Volts grade of size 3 core 95 Sqmm complete all as specified and directed.
Supply, Laying and testing cable XLPE insulated screened, PVC beddd, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 3.5 core 25 Sqmm complete all as specified and directed.
Supply, Laying and testing cable XLPE insulated screened, PVC beddd, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 4 core 16 Sqmm complete all as specified and directed.
Supply, Laying and testing cable XLPE insulated screened, PVC beddd, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 3.5 core 240 Sqmm complete all as specified and directed.
Supply, Laying and testing cable XLPE insulated screened, PVC beddd, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 3.5 core 180 Sqmm complete all as specified and directed.
S & F for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 sqmm complete all as specified and as directed.
Supply and Fixing Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.00 metres long) including anti climbing device, PCC foundation , cross arms, two coats of painting over a coat of primer etc complete all as specified and as directed.
Item No43.00 contd......... OUTGOING FEEDERS (a) MCCB 1 Pole 400 A rating Icu=Ics= 50 kA with adjatable TM release with extented terminals-01 Nos (b) MCCB 1 Pole 250 A rating Icu=Ics=36 kA with adjatable TM release with extented terminals-02 Nos (c) MCCB 1 Pole 160 A rating Icu=Ics=25 kA with adjatable TM release with extented terminals-02 Nos (d ) Time swicth for street light control comparing of MCB TPN 32 Amp with breking 10 KA 01 nos, astro type (Having longitude and latitude of Indian cities in memory) 250 v single phase of 20 Amp rating time switch - 01 Nos with heavy duty power contactor 40A TPN with 2 No + 2NC & wiring complete- 01 Set (e) MCB, SPN, 10 Amps - 01 No (f) Time switches 250 V single phase of 20 Amp rating with contactor. Note (i) Pre-dispatch inspection at OEM/factory premise shall be carried out by Ref of Accepting Officer. (ii) Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer. (iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/EI.
M&L copper strips 20 x 3.15 mm with saddles and fixing screw etc, for roof conductors and down conductors above ground complete all as specified and directed
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for lying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated material(Soils) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed
M & L for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed. (Note :- Thickness after consolidation be measured for payment)
Supply, laying in trenches burnt bricks old size of 230 x 115 x 75mm sub class B bricks for cable protection complete all as specified and directed.
M & L for cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M & L for PCC (1:3:6) , type C-1 (using 20 mm graded crushed stone aggregate) in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including formwork if required , complete all as specified and as directed
M & L for PCC (1:2:4) , type B-1 (using 20 mm graded crushed stone aggregate) in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including formwork if required , complete all as specified and as directed
S&F danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. claimps, bolts and nuts of approved size 25x20cm for HT 11 KV complete all as specified and as specified.
M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground, earth pit not less than 2.25mtr deep below ground level with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth strip 32 x 6mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel etc complete as shown in electrical Plate No.3 of SSR Part-I (2009), protected by 40mm bore light grade galvanised iron pipe and other end connected to earthing test point or body of pole or lightning arrestor or main, controlling switch as directed including funnel with watering pipe of 20mm bore light grade galvanised iron wire mesh charcoal or coke and common salt in alternate layers of 15cm (compacted thickness) around the earth electrode and Concrete earth pit in PCC(1:3:6) type C-1, 50mm thick pre cast RCC 1:1.5:3 type A-1 cover slab reinforced with 8mm dia mild steel TMT bar @ 15cm centre to centre both way and suitable handle of 10mm dia round bar, including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50m and necessary testing complete all as specified and as directed. [Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth leas and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) Excavation/earthwork is deemed to be included in the quoted rate.]
M&L for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (earth plate not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to and including copper earth strip 32 x 6 mm as earthing strip by means of bolts,nuts ,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part-1 including necessary excavation and earth work in soft/disintegrated soil, PCC (1:3:6) type C-1 with 50mm thick precast RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia deformed bar @15cm C/C both ways and suitable handle of 10mm dia round bar including coke/charcoal dust and common salt alternate layers of 15cm compacted thickness all around the earth electrode , to provide stable low resistance in the earth terminal, with funnel and 20mm bore galvanised watering pipe (light grade) ,wire mesh , ,complete in all respect ,Copper strip protected by 40 mm bore (light grade ) GI pipe , other end connected with earthing test point as directed ,including returning filling with fresh vegetable black soil and disposal of excavated soil to a distance not exceeding 50mtr and necessary testing on completion complete all as specified and as directed. [Note : (a) The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth leas and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) Excavation/earthwork is deemed to be included in the quoted rate.]
Sch 'A' Part-II (SCHEDULE OF CREDIT) Note :- Amount of Rs 1,60,480.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
M/s KUMAR BUILDERS
M/s Singh enterprises
ms singh construction
Rajan Traders
M/s PRABIR ENTERPRISE
SHRI GANESH ENTERPRISES
Phoenix Infra
ANZ CORPORATION
M/s Gupta Construction
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .