Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC EAST DIGHI TANK OLD LIC COMPOUND GAYA BIHAR 823001 | GAYA | BIHAR | 823001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹13.8 L+₹1.3 L (10.5%)Rejected-Finance MOCHARIM BODHGAYA GAYA 824231 | GAYA | BIHAR | 824231 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹14.1 L+₹1.7 L (13.5%)Rejected-Finance 11A LAXMI VIHAR BANDHAN PALACE WALI GALI MODIPURAM MEERUT UTTAR PRADESH 250110 | MEERUT | UTTAR PRADESH | 250110 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹16.2 L+₹3.8 L (30.3%)Rejected-Finance 607 6TH FLOOR PRATEEK CENTRE SANJAY PLACE AGRA 282002 | AGRA | UTTAR PRADESH | 282002 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹19.8 L
EMD Value
₹39,500
Closing Date
3 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GAYA
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar, PIN-823005
Provn of prepaid Electric Meters alongwith allied services at Mil Stn Gaya
2023_MES_622807_2
8051/GE/E8
Open Tender
Civil Works
Item Rate
90 days
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GAYA
₹39,500
Yes
22 Mar 2024
19 Dec 2023
5 Jan 2024
19 Dec 2023
3 Jan 2024
21 Dec 2023
Amount
Taking down old type/ defective electric energy meters of Single/Three phase after noting down the reading and depositing the same in MES store yard complete all as specified and as directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs including old unserviceable MCCBs/ MCBs, etc complete all as specified and directed.
Supply of 3-Phase 4-wire 3x240 Volts Class 1.0 Smart Energy Meter complying to IS:16444 Part- 1/ 2015 (reaffirmed 2020) at the rating of 10-60 Am suitable for Prepaid/ Postpaid mode with lon range RF module with Polycarbonate Meter Box. The Smart Meter shall support the following minimum basic features:- (a) Measurement of electrical energy parameters (b) Bidirectional Communication (c) Integrated Load limiting/connect/ disconnect switch (d) Tamper event detection recording and reporting (e) Power event alarms (f) Remote firmware upgrade (g) TOD features (h) On demand reading. In addition to above the smart meter shall have the ability to communicate with Head End System (HES) on RF Communication technology mentioned in IS:16444 Part 1/ April 2020 in a secure manner and data exchange protocol from smart meter to HES shall be based on open protocol like TCP/lP or DLMS/COSEM and RF network should use 865-867 MHz frequency band as permitted by WPC complete all as specified and directed.
Supply of long range gateway with 01 KM dia RF coverage arrangement of SIM cards or internet to enable reliable medium for two-way communication between RF based Smart Meters & HES . The smart Meter shall support the following minium basic feature:- (a) The data acquisition (Push/Pull) frequency shall be configurable in events such as tamper, power off etc to HES immediately on occurrence/receipt from meters. (b) It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. (c) It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1 phase/ 3 phase). (d) It shall be able to communicate with the nearest meters at a distance of at least 500 m and able to established through appropriate mesh formation depending on topographical features and RF Mesh shall support self-forming and self-healing features. (e) The equipment shall be weather proof and dust proof (minimum rating IP-54 for indoor and IP-65 for outdoor installation). (f) It shall have rechargeable battery with backup for one hour for normal meter reading, to push tamper event, carry out on demand reading, etc.
Supply of Single-Phase RF-based Smart Meters as Repeaters to ensure connectivity of main Smart Meters with RF Gateway having features of AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 Volts, 50 Hz, 5-30A/10-60A conforming to IS:16444 Part-1/ April 2020 with inbuilt 865-867 MHz Radio Frequency communication facility with self-healing Mesh network with default and on demand display, anti-tamper features, Microprocessor and LED based circuitry, the meter shall support communication as per IS:15959 (Part 2) 2011 and shall support open communication protocol DLMS with the software.
Installation, Testing and Communication of above Smart Energy meters, Repeaters and RF Communication
Supply, installation, testing & commissioning of Cloud-Hosted multi-user web-based software with 2-years defect-liability period with following features and modules: (a) Head End System (HES) to acquire meter data automatically from DCUs and monitor parameters acquired from meters. (b) Meter data management Modules: Meter data management module shall collect the data from the concentrator and make the data available to the billing system also capture & provide the following data:- (c) 30 min instantaneous data from all the meters for seven parameters - cumulative energy, Power, current, Voltage, Power factor and frequency. (b) Monthly and quarterly billing survey data for cumulative energy and max demand. (d) Billing Module: The billing module shall collect the data from the meter data management module, calculate billing determinant and make energy data / billing data available to admin & end user. There shall be provision for entry of change in the tariff structure by MES staff as decided time to time. (e) Occupation and Vacation module: The system shall support occupation/vacation based on the unit categories. (f) Website: There shall be a dedicated website for AGE/GE and BSO team to view all the data and information along with customer portal for use of customer. The designated users in MES shall have the admin access to the application. The MES Staff shall also have the access to the key information on mobile App (Android and iOS based) for admin use. (g) Customer Module: The system shall include a customer portal for the resident/occupants to log in and view their own energy/billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility. (h) Communication Module: The system shall provide communication of energy data and bills via print, email and SMS.
Item No. 7 condt...... (h) Communication Module: The system shall provide communication of energy data and bills via print, email and SMS. (j) Meter Master Data: The system shall support meter data repository and support meter replacement process. (k) Excel Export: The system shall support export of metering and billing data in excel and pdf format. (l) Energy Accounting module : The system shall include features of energy accounting and able to account for total energy block wise, facility wise and shall also allow calculations of the unaccounted energy in case total energy meter is also available. (m) Prepayment/Recharging Facility: The system shall periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system shall allow online / digital recharging through consumer App (Android and iOS based) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system shall send connect/disconnect command on the basis of available credit. (n) Low Credit Alarm: The system shall give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down below a predefined limit.
Annual Comprehensive Maintaenance of Smart Energy Meters, Communication, Sim card rental or internet charges, Applications. Software assistance for 3 years period after 2 years of defect liability period.
M & L for Sub main wiring with 4 nos. single core PVC insulated-unsheathed 6 Sq mm FRLS stranded copper conductor cable & 2 no. single core PVC insulated-unsheathed 4 Sq mm FRLS stranded copper conductor cable for earth continuity, drawn in & including suitable dia (but not less than 25 mm dia) concealed rigid non metallic PVC conduit with fittings (ISI marked) complete all as specified and directed. Note: (i) Length of 4 nos. 6 Sqmm conductor cable & 2 nos. 4 Sqmm conductor earth continuity cable & PVC conduit shall be measured as one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iii) Cutting chases shall be deemed included in quoted unit rate.
S & F sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
S & F MCB tripple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed.
S & F MCB single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and directed.
MAA BHAGWATI TELECOM LINK
SINGHAL ENTERPRISES
INVENTIVE SOFTWARE SOLUTIONS PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .