Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹2.5 L
Closing Date
9 Mar 2026, 3:00 pmClosed
Provision of dual detection for Automatic section in between SZM-SNP and PNP- BBDE section of Delhi Division.
558-Sig-16-M-Tender-1467~NR
558-Sig-16-M-Tender-1467
Open
Works - General
12 Months
North Delhi, Delhi
₹0
₹2.5 L
9 Mar 2026
16 Feb 2026
23 Feb 2026
A-Provision of dual detection for Automatic section in between SZM-SNP
Supply of Tool Kit for installation and Maintenance of MSDAC as per OEM requirement comprising of - Portable Data Analyser for downloading event logger data for analysis and report 1 generation - 1 No. - True RMS digital multimeter of reputed make - 1 No. -Dummy wheel-1 No. - Set of Spanners and Screw drivers including soldering iron - Adjustable Torque wrench - 1 No. - Marking jig for drilling - Any other specialised tools and measuring equipments as per OEM requirement. The technical specification for the concern item is explained in the Annexure-Tech Spec. under Chapter- III (i.e. Scope of The Work and Technical Specifications) of tender Document. Inspection: Consignee.
Supply, Installtion & Commissioning of maintenance free earth suitable kit as per RDSO Specification no. RDSO/SPN/197/2008 and Drg No. SDO/./E&B/001 dated:- 19.09.2008 and Drg No. RDSO/SDO/./E&B/002 dated:- 19.09.2008. Earthing kit consisting of earthing electrode of 17mm dia as 3m long -01 no 2 MEEB (300mmx25mmx6mm) -ol no. 3. SEEB (150mmx25mmx6mm) -01 no 4. Earth enhancing compound - 30 kg (minimum). This includes:- Provisiion of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data Logger etc. 2 with PVC earth wire of size 25/35 sq.mm through copper lugs of suitable size PVC earth wire shall be supplied by Contractor. Note: At certain locations, it may not be possible to acheive earth resistance of less than 1.0 ohm with one earth electrode /pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done, for interconnection of two earth pits copper tape of size 25x2 sq.mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as seperate earth. Inspection : RDSO for supply.
Fabrication, supply and fixing of relay racks of size 2200mmx690mm (as per approved Drg. No. NR/S&T/CON/4-3/97A) made of angle iron size 45mmx45mmx6mm alongwith outer frame made of angle iron size 65mmx65mmx8mm, fitted with M.S. squares bars duly galvanised, descriptions strips to accommodate Plug-in-type relays/groups/Point contractor units/ECRs/HMUs. All fixing material like antilting device, hylam sheets if required, bolts & nuts, washers, insulators, shoe, angle irons, flats, L-bolts, Catenary wires and cement concrete etc. will be supplied by the contractor. This includes cleaning, priming by red oxide, painting & description etc. with ISi mark paints. Inspection by Site Engineer.
Supply & Installation of Thermo shrink jointing kit for 6-Quad/4-Quad cable for 4 straight through joints as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations. Jointing kits to be supplied as per RDSO specification IRS:TC 77-2012 (Rev.-3) or latest amendments. Inspection : RDSO
Supply of single app.case steel RE with 'E' type lock and key ward no.42 and handle as per drg. No. RE/S&T/ALD/SK/219/82 with (Alt A) and 221/82 with Alt.B. Inspection :Consignee
Casting, concreting and curing of foundation and erection of single app.cases of size (1160mmx760mm) at surface and 650mm deep as per approved Drg.No.NR/S&T/CON/2-7/97. A 6 layer of 3 mm of bitumen compound has to be provided between foundation and location box to prevent ingress of water in the base of location box . All material such as cement,coarse sand,aggregate and anchor bolt shall be supplied by contractor . App. Case single will be supplied by Railway. Contractor is required to execute all type of repair Works of foundations if required during inserting the cable for termination. Inspection by Site Engineer
"Preparation of App. Case single not involving wiring of relays. Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x10mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal and fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable 7 in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses with bases, catenary wires , nuts and bolts and other items shall be supplied by the contractor. ARA terminals only shall be supplied by the Railways. Inspection by Site Engineer "
"Termination of main signaling/power cable & tail cable in the main cable. Termination board/location box/Jn. Box. It includes lacing of cable, terminal fuses base after drilling suitable holes. Inspection by Site Engineer"
All work of horizontal boring and trenchless cabling along with supply,transpotation and insertion of double wall corrugated pipe -( ISI marked ) conforming to RDSO Spec no. 9 RDSO/SPN/204/2011 or latest, and the laying of cable in the boring under the track / road etc as per instruction of site engg. by using pipe of size 120 mm outer dia, 103.5 mm inner dia in which required number of cables to be crossed. The depth of horizontal boring should be minimum 1.0 m from rail flange/road level. Inspection : RITES for DWC pipe.
"Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.NR/S&T/CON/1. 1/97-A so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. Deep. Inspection by Site Engineer"
Supply and laying of 2nd class bricks in the trench and laying as per drg. No.NR/S&T/CON/1. 1/97A as per instructions of the site Engineer.
"Laying of signalling/Telecom/power cables of different sizes as per drg. No. NR/S&T/CON/1. 1/97A and as per cable route plan approved by Railways and meggering of cable before and after its laying of all type of outdoor cables. Inspection by Site Engineer "
Supply and installation of ARA terminal size of 25 mm on terminal board in JB/location box. ARA terminal must be from RDSO approved firm and conforming to IRS SpecIRS 75/91. Inspection by RDSO
Supply and fixing of G.I. pipe perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per drg. No. (NR/S&T/CON/1. 4/97) Inspection: for supply Consignee, for fixing Site engineer.
Conventional earth : Supply and installation of earth electrodes as per std. practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe. Casting of cement concrete enclosures as per drg. No. (NR/S&T/CON/6.4/97). Inspection by Consignee
Supply of electric fuse complete with fuse block(base) for Railway signalling non- detoriorating round head type low voltage fuse 2Amp/4Amp/6Amp. to suit RDSO Specn. No.IRS: S- 78/92 Inspection : RDSO
General concrete work in cement, coarse sand and aggregate ratio 1: 3:6, work 17 scattered at different places for items not covered in above schedule and fine plastering of top will be done with cement sand ratio of 1:4 . Volume of foundation also includes volume of C.I. base, anchor bolts etc. Coarse sand, aggregate 25mm and cement to be supplied by contractor. Inspection : Site Engineer
Supply and installation of 24-32 Volt/5Ampere DC-DC convertor module suitable for IPS systems as per instruction of Site In charge and RDSO spec No.RDSO/SPN/ 165/ 2012 ver.3.0 or latest. Inspection:RDSO
Supply of digital Earth Tester 04 terminal, range 0-10/100ohm with rechargeable 19 battery with accessories kit. Note: - The technical specification for the concern item is explained in the Annexure-Tech Spec. under Chapter- III (i.e. Scope of The Work and Technical Specifications) of tender Document. Inspection: Consignee
Supply of Megger 500V Digital electronic push button type, model D2-KM or similar. 20 Note: - The technical specification for the concern item is explained in the Annexure-Tech Spec. under Chapter- III (i.e. Scope of The Work and Technical Specifications) of tender Document. Inspection: Consignee
Supply of Portable digital auto range multi- meter (Philips, Motwani, Fluke, Rishabh make model Rish Max12 or similar) capable to measure from (0.1mv/0.01ma), AC/DC upto 21 10Amp(AC/DC), 1000V(AC/DC) and 0.1 ohms to 40M ohms. Suitable for measurement of freq, capacitance. Note: - The technical specification for the concern item is explained in the Annexure- Tech Spec. under Chapter- III (i.e. Scope of The Work and Technical Specifications) of tender Document. Inspection: Consignee.
Supply of Electric track drilling machine equipment consisting of Heavy duty electric 22 track drilling machine works on 110V 50 Hz AC with suitable interchangeable track mounting stand with depth adjusting facility . Make of heavy duty electric drilling machine is of Rallies or Wolf or Bosch only Firm's Offer:MAKE/BRAND:Bosch machine model no 13-20230 volt mac or similar. Inspection by Consignee
Supply of AC/DC clamp meter 40/100 amp make fluke 317/319, Koico 3540 or similar with resolution of min. 0.01 amp with 37 mm clamp opening .meter compises of AC/DC voltage,resistance,frequency and continuity measurement.Inspection by Consignee
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDoc1467.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .