Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | ₹22.0 L | L1 | Accepted-AOC Being first lowest |
| 2 | L2₹28.0 L+₹6.0 L (27.3%)Rejected-Finance | ₹28.0 L+₹6.0 L (27.3%) | L2 | Rejected-Finance Other Than First Lowest |
| 3 | L3₹28.5 L+₹6.5 L (29.7%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹28.5 L+₹6.5 L (29.7%) | L3 | Rejected-Finance Other Than First Lowest |
| 4 | L4₹34.6 L+₹12.6 L (57.4%)Rejected-Finance | ₹34.6 L+₹12.6 L (57.4%) | L4 | Rejected-Finance Other Than First Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
18 Feb 2025, 6:00 pmClosed
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR/REPLACEMENT OF OLD UNSERVICEABLE INTERNAL WIRING AND CONNECTED ACCESSORIES FOR OFFRS MD ACCN AT LGJ MIL STN
2025_MES_694190_1
8935-37/GE/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender document
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹60,000
Yes
8 Mar 2025
21 Jan 2025
20 Feb 2025
21 Jan 2025
18 Feb 2025
4 Feb 2025
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator etc and making good distrubed surfaces of walls and floors etc to match with the existing all as specifided and directed.
Taking down MCB isolators sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces.
Taking down carefully submain wiring/ service connection of any type complete with casing caping / conduit etc complete all as specified and directed.
Material and labour for concealed Point wiring for one light point controlled by one way one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ).
All as per srl item No 4 above, but for One 3 pin switch socket outlet, 5 Amp on the same board with other switches all as specified
All as per srl item No 4 above, but for One 3 pin 5 amps switch socket outlet point on independent board all as specified
All as per srl item No 4 above, but for One bell/buzzar point controlled by one bell push all as specified
All as per srl item No 4 above, but for two way point controlled by two way switch all as specified
All as per srl item No 4 above, but for one ceiling/exhaust fan point controlled by one switch and regulator all as specified
All as per srl item No 4 above, but wiring with 2.5 Sqmm multistranded cable and earth wire with copper conductor of size 2.5 Sq mm for 15 amps all as specified
Supply and fix in repair piano swith flush button single pole one way 5/6 Amps 230 Volt AC complete all as specified and directed
Supply and fix in repair piano swith flush button single pole two way 5/6 Amps 230 Volt AC complete all as specified and directed
Supply and fix in repair piano swith flush button single pole one way 15/16 Amps 230 Volt AC complete all as specified and directed
Supply & fixing in repair electric buzzer/ ding dong bell 5 amp 230 volts AC supply complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair of socket two in one, 6 pin 5 Amp and 5 Amp flush type all as specified & directed
M & L in repair of socket two in one, 6 pin 5 Amp and 15/16 Amp flush type, 230 Volt AC all as specified & directed
Supply and fix in repair Modular switch 1 way 6 A, 1 module complete all as specified and as directed.
Supply and fix in repair Modular switch 1 way 16 A, 1 module complete all as specified and as directed.
Supply and fix in repair Modular bell push 6 A, 1 module complete all as specified and as directed.
Supply and fix in repair of socket two in one, 6/10A 2/3 pin combined 2 Module all as specified & directed
S& F in repair socket two in one, 16/15A 2/3 pin combined 2 Module all as specified & directed
Supply and fix in repair coard less bell of different music AC 230V complete all as specified and directed
S & F in repair casing capping patti suitable for 3 core/1.5 Sq mm/2.5 Sq mm wire compelte all as specified and direded
S & F factory made sheet metal distribution boards, SPN, 12 way double door; protection class IP-30 suitable for mounting MCB/ conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed.
S & F factory made sheet metal distribution boards, SPN, 8 way; double door; protection class IP-30 suitable for mounting MCB/ MCCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed.
S & F factory made sheet metal distribution boards, SPN, 4 way; double door, protection class IP-30 suitable for mounting MCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed.
S & F factory made sheet metal distribution boards, SPN, 2 way; Single door, protection class IP-30 suitable for mounting MCB, conforming to IS- 8623 with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply complete all as specified & directed.
S & F MCB tripple pole 63 Amp, 415 Volts, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed.
S & F MCB SPN 40 Amp, 240 Volts, rupturing capacity 10 KA confirm to IS- 8828- 1996, IEC - 60898 complete all as specified & directed.
S & F MCB SPN 6-32 Amp, 240 Volts, rupturing capacity 9 KA confirm to IS- 8828-1996, IEC - 60898 complete all as specified and directed
Supply and fix isolator 4 poles 63 Amps 415 volt 50 Hz complete all as specified and directed
Supply and fix isolator 4 poles 100Amps 415 volt 50 Hz complete all as specified and directed
S & F in repair square shape, intrigal decorative LED bollard with opal acrylic with IP 65 protection of (tetris) product code 111771 type BGBOS 600 9 watt LED warm white colour complete all as specified and directed
Supply and fixing in repair LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
S & F in repair Lamp holder incl LED lamp 9 watt, insulated body with back plate etc all as specified and as directed.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-In-Charge
Supply and fixing in repair LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : <15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply & fixing in repair ceiling rose surface bakelite 65 mm x 50 mm size, 3 terminals complete all as specified and directed.
Supply and fix in repair Switch socket combination 2 in 1, 5 A flush type complete all as specified and as directed.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 inculding complete all as specified and as directed.
Supply and fix in repair Switch socket combination 2 in 1, 5 A with box complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair Switch socket combination 5A/16A, 5 in 1 with box complete all as specified and as directed.
Supply and fixing SPN 63 Amp 240V, 10KA 'C' curve miniature circuit breaker (MCB) with connection testing and commissioning complete all as specified and directed by Engr-In-Charge
Supply and fix Vertical DB 4 way suitable for Double Pole including outgoing MCB-40 Amp-04 Nos with incoming 100 Amps MCCB 4 pole-01 Nos complete with 250 Amps rated Copper busbar flush mounting, double door, proction class IP-30, IK08 complete all as specified and as directed by Engineer-in-charge.
S & F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by Engr in charge.
S & F in repair modular fan regulator, 120W-2 Module complete all as specified and directed by Engr in charge.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 4 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 10 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
Supply and fixing in repair energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fix in repair Fresh air fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 MM complete all as specified and directed by Engr-In-Charge. Old U/S Fresh air Fan will be deposited to MES Store yard by the contractor .
S & F in repair 1100 volts grade heavy duty PVC insulated aluminium stranded conductor cable served with inner sheathing twin core flat or circular of size 10 sqmm in service connection & suspended by insulating hangers not more than 1 metre apart including 4 mm dia GI suspension wire all as specified & directed.
Supply, laying, testing and commissioning in repair cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/ cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge
Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed
M&L sand cushioning with dry and clean locally available sand for under ground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note : Punned thickness shall be considered for payment purpose)
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
M&L for boring under roads for crossing of UG Cables complete all as specifie and directed by Engr-In-Charge.
Supply and fix GI Pipe light grade of size 40 mm laid in trenches under road/fixed on wall/pole for cable protection complete all as specified and directed by Engr-In-Charge
Note:- Contractor will submit all the old unserviceable item retrived from above mentioned schedule of item to MES store yard. Transportation charges for the same is responsibility of contractor and no extra payment shall be made on this account
Lalgarhia Enterprises (BID ID -3236010)
Singla Electricals (BID ID -3242269)
Ganganagar Enterprises (BID ID -3242684)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .