Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹20.9 L+₹1.6 L (8.16%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-Finance Higher | |
| 3 | L3₹22.2 L+₹2.9 L (15.0%)Rejected-Finance | L3 | Rejected-Finance Higher |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
28 May 2020, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Repair and maint of water supply installation, pumping sets, motor starter panel and over head tank at Tibri Mil Stn under GE Gurdaspur.
2020_MES_334015_2
GE GSR-69/2019-20
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer, Gurdaspur (Tibri)
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹60,000
12 Jun 2020
27 Apr 2020
30 May 2020
27 Apr 2020
28 May 2020
1 May 2020
Amount
M&L for taking out of submersible pump and motor of 50 to 55 HP capacity from bore including flanged column pipes with chain pulley arrangements and engaging sufficient man power to ensure safety of equipment/plant as well as working persons including disconnecting of delivery main lines and electric connections and lowering the same including reconnecting the flanged column pipes and delivery main lines and electric connections of the same after completion of repair complete all as specified and directed. Note :- (i) The whole job of repair/rewinding of submersible pump should be completed within 24 hours of reporting the non working of the submersible pump set, time will be counted when rep of this office will inform the contractor by means of telephone, massege, what's Up, letter etc. Failing which Rs 200/- per hour will be deducted as compensation. (ii) One rep of the contractor will visit daily to pump houses to the check the smooth functioning of the Submersible pumps and healthy operation of the starter panel and report the same to JE Incharge and Engineer- in-charge on daily basis.
All as per item No. 02 here-in-before but for submersible pump and motor of 40 to 45 HP capacity.
All as per item No. 02 here-in-before but for submersible pump and motor of 10 to 20 HP capacity.
All as per item No. 02 here-in-before but for submersible pump and motor of up to 4 HP to 7.5 HP capacity.
All as per item No. 02 here-in-before but for submersible pump and motor of up to 1 HP to 2 HP capacity.
M&L for dismantling of electric driven submersible pump motor of capacity 50 to 55 HP, taking out the burnt winding, cleaning and washing of slots and rewinding the motor with water resistant proof copper winding wire of existing gauge and quantity ( as per original manufacturer design) including replacement of all damaged parts, insulating materials such as insulating sheets insulating paper , insulating heat resistant sleeves, sealing compounds varnish etc and reassembling the motor, commissioning complete all as specified and directed. Note :- (i) Winding wire will be measured and paid separately under relevant items. (ii) The contractor will furnish six month warranty against any kind of defect for the repair carried out after the date of installation.
All as per item No. 07 here-in-before but for submersible pump and motor of 40 to 45 HP capacity.
All as per item No. 07 here-in-before but for submersible pump and motor of 10 to 20 HP capacity.
All as per item No. 07 here-in-before but for submersible pump and motor of up to 4 to 7.5 HP capacity.
All as per item No.07 here-in-before but for submersible pump and motor of up to 1 to 2 HP capacity.
M&L for taking out submersible motor shaft, refitting/refilling of metal at corroded portions including all welding, turning and other machine works required to make the shaft fit to shape and size as suitable for 50 to 55 HP capacity.
All as per item No. 12 here-in-before but for submersible pump and motor of 40 to 45 HP capacity.
All as per item No. 12 here-in-before but for submersible pump and motor of 10 to 20 HP capacity.
All as per item No. 12 here-in-before but for submersible pump and motor of up to 4 to 7.5 HP capacity.
All as per item No. 12 here-in-before but for submersible pump and motor of up to 1 to 2 HP capacity.
S&F in replacement thrust plate for submersible motors of capacity from 50 to 55 HP.
All as per item No. 17 here-in-before but for 40 to 45 HP.
All as per item No. 17 here-in-before but for 10 to 20 HP.
All as per item No. 17 here-in-before but for 4 to 7.5 HP.
All as per item No. 17 here-in-before but for 1 to 2 HP.
S&F in replacement gun metal bush for submersible motor cover of capacity from 50 to 55 HP.
All as per item No 22 here in before but for 40 to 45 HP.
All as per item No 22 here in before but for 10 to 20 HP.
All as per item No 22 here in before but for 4 to 7.5 HP.
All as per item No 22 here in before but for 1 to 2 HP.
S&F in replacement of the Pump sleeves stainless steel for submersible motors of capacity from 50 to 55 HP.
All as per item No. 27 here-in-before but for 40 to 45 HP.
All as per item No. 27 here-in-before but for 10 to 20 HP.
All as per item No. 27 here-in-before but for 4 to 7.5 HP.
All as per item No. 27 here-in-before but for 1 to 2 HP.
S&F in replacement of the stainless steel impeller for submersible motors of capacity from 50 to 55 HP.
All as per item No. 32 here-in-before but for 40 to 45 HP.
All as per item No. 32 here-in-before but for 10 to 20 HP.
All as per item No. 32 here-in-before but for 4 to 7.5 HP.
All as per item No. 32 here-in-before but for 1 to 2 HP.
S&F in replacement stainless steel bush for submersible motors of capacity from 50 to 55 HP.
All as per item No. 37 here-in-before but for 40 to 45 HP.
All as per item No. 37 here-in-before but for 10 to 20 HP.
All as per item No. 37 here-in-before but for 4 to 7.5 HP.
All as per item No. 37 here-in-before but for 1 to 2 HP.
S&F in replacement of the oil seal for submersible motors of capacity from 50 to 55 HP.
All as per item No. 42 here-in-before but for 40 to 45 HP.
All as per item No. 42 here-in-before but for 10 to 20 HP.
All as per item No. 42 here-in-before but for 4 to 7.5 HP.
All as per item No. 42 here-in-before but for 1 to 2 HP.
S&F in replacement of the gun metal housing bush for submersible motors of capacity from 50 to 55 HP.
All as per item No. 47 here-in-before but for 40 to 45 HP.
All as per item No. 47 here-in-before but for 10 to 20 HP.
All as per item No. 47 here-in-before but for 4 to 7.5 HP.
All as per item No. 47 here-in-before but for 1 to 2 HP.
S&F in replacement of the stainless steel shaft for submersible motors of capacity from 50 to 55 HP
All as per item No. 52 here-in-before but for 40 to 45 HP.
All as per item No. 52 here-in-before but for 10 to 20 HP.
All as per item No. 52 here-in-before but for 4 to 7.5 HP.
All as per item No. 51 here-in-before but for 1 to 2 HP.
S&F in replacement of the neck ring bush for submersible motors of capacity from 50 to 55 HP.
All as per item No. 57 here-in-before but for 40 to 45 HP.
All as per item No. 57 here-in-before but for 10 to 20 HP.
All as per item No. 57 here-in-before but for 4 to 7.5 HP.
All as per item No. 57 here-in-before but for 1 to 2 HP.
M&L for disconnecting of delivery, suction pipes and electric connections, taking out of centrifugal horizontal pump set of any capacity and transporting to workshop for repair and back to existing site after complete repair, reinstalling, reconnecting the suction, delivery pipes and electric connections of the same after completion of repair.
Supply only in replacement Enamelled copper winding wire of superior quality approved by Garrison Engineer for winding of centrifugal horizontal, submersible motors complete all as specified and directed .
Supply only in replacement water resistant copper winding wire of superior quality for winding of centrifugal horizontal, submersible motors complete all as specified and directed .
M&L for dismantling of electric driven centrifugal horizontal pump motor of any capacity taking out the burnt windings cleaning and washing of slots and rewinding the same with enamalled copper winding wire of existing gauge and quantity ( as per original/ manufacturer design )including replacement of all damaged parts, insulating materials such as insulating sheets insulating paper , insulating heat resistant sleeves, sealing compounds varnish etc and reassembling the motor. Note : (i) Winding wire will be measured and paid separately under relevant items. (ii) The contractor will furnish one year warranty against any kind of defect for the repair carried out after the date of installation.
S&F in replacement Pump shaft of the centrifugal horizontal type pump set of 5 HP capacity suitable for centrfugal type pump set of 5 HP capacity.
S&F in replacement ball bearing suitable for centrfugal type pump set of 5 HP capacity as per existing size.
S&F in replacement rubber coupling suitable for centrfugal type pump set of 5 HP capacity as per existing size.
S&F in replacement CI coupling suitable for centrfugal type pump set of 5 HP capacity as per existing size.
S&F in replacement CI impeller suitable for centrfugal type pump set of 5 HP capacity as per existing size.
S&F in replacement gun metal bush complete for centrfugal type pump set of 5 HP capacity as per existing size.
M&L for stud with nuts including spring, washers and angle iron etc suitable for submersible pump motor complete all as specified and directed.
S & F in replacement 3Pole power contactor, type MNX95, 415 Volts, AC3 rating, 95 amp, AC-1 rating 160 amp, aux contacts 2No + 2NC Make L&T Cat part No. CS94136 or equivalent complete all as specified and directed .
S & F in replacement, 3Pole power contactor type MNX70, 415 Volts, AC3 rating 70amp, AC-1 rating 100amp, aux contacts 2No + 2NC Cat part No. CS-97076, Make L&T or equivalent complete all as specified and directed .
S & F in replacement, 3Pole power contactor type MNX140, 415 Volts, AC-3 rating 140 amp, AC-1 rating 160 amp, aux contacts 2No + 2NC Cat part No. CS 94138, Make L&T or equivalent complete all as specified and directed .
S & F in replacement 3Pole power contactor, type ML4, 415 Volts, AC3 rating, 70 amp, AC-1 rating 100 amp, aux contacts 2No + 2NC Make L&T Cat part No. SS90910 or equivalent complete all as specified and directed .
S & F in replacement thermal overload relay, direct mounting ,type MN5, relay range 45-75, Make L&T Cat No. SS94137OOJO, or equivalent all as specified and directed complete
S & F in replacement thermal overload relay, direct mounting ,type MN5, relay range 66-110, Make L&T Cat No. SS94137OOJO, or equivalent complete all as specified and directed .
S & F in replacement electronic timer, type ST100, 240 Volts 12 -120sec, Make L&T Cat part No. ST803290000 or equivalent complete all as specified and directed .
S & F in replacement DOL (Direct online) starter AC3, 3phase, 415 Volt, 9-15amp, Type MF1, Make L&T catpart no. SS97210, or equivalent complete all as specified and directed .
S & F in repalcement of Single phase preventor VSP3 type (Auto Reset, 50 Volts unbalance) Make:- Minilec and equivalent complete all as specified and directed by Engineer-in-Charge.
S & F of MS column pipe, 150mm bore, 5.4mm thick, heavy duty, with flanged ends, complete including nut and bolts and gaskets required complete and including taking out existing old, unserviceable column pipe complete all as specified and directed.
S & F of MS column pipe, 100mm bore, 5.4mm thick, heavy duty, with flanged ends each complete including nut and bolts and gaskets required complete and including taking out existing old, unserviceable column pipe complete all as specified and directed.
M&L for cleaning of over head reservoir of 2,00,000 gallon capacity including scrapping of scales, flushing out of silt and muddy water, washing with anti bacterial solution etc to the entire satisfaction of GE/Engineer-in-charge consisting of following cleaning process :(a) Testing/Pitchurization and dewatering : Testing in terms of oxygen level inside the tank, water TDS testing and pitchurization inside the tank to provide with before/after cleaning images, Dewatering of the water tank with submersible pumps.(b) SLUDGE REMOVAL : Removing of any type of sludge, accumulated mud, silt, sand, vegetation growth or any solid particles etc. from bottom surface and inner walls of tank with the help of sludge pumps or manually disposing off the same to a distance exceeding 50 mtrs but not exceeding 100 mtrs away from the fencing of installation, and spreading in low lying areas.(c) ALGAE REMOVAL : Removal of Algae, Calcinations etc from the walls with rotary cleaner/scrubber machine/wire brushes etc.(d) INTERNAL WASHING : Washing of Walls and Ceiling with the help of high pressure jet cleaners using fresh and clean water.(e) ANTI-BACTERIAL TREATMENT : Walls and ceiling to be sterilized with food grade anti-bacterial solution for making it bacteria free.(f) VACUUM CLEANING : Complete removal of remaining sludge, accumulated mud, silt, sand with the help of vacuum cleaners.(g) Air purification: Tank to be sterilized and disinfected with the help of ozone gas to make the tank bacteria free.Note : 1. All the equipment/material required for cleaning of tank will be brought by the contractor and no extra cost will be paid in this effect. 2. The contractor must intimate atleast one week in advance for cleaning of tank and only after approval of Engr -in-charge/GE, the cleaning will be carried out.3. The contractor must carry out all the process in such a way that the complete inside cleaning process as mentioned above must be finished in one day only to cause minimum disturbance to regular water supply to connected area. 4. The contractor must cater for all safety arrangement i. e. safety belts/ helmet / safety harness, scaffolding etc for working man power and inspecting staff and no extra cost will be paid in this effect.5. The cost of cleaning area / grass cutting / removal of minor bushes / roots of dead tree within 15 metre radius from plinth protection of the tank shall be deemed to be included in the unit rate quoted by the contractor.6. The branches of trees covering the roof of OHR should be trimmed by the contractor up to 5 mtr distance from OHR and no extra cost will be paid in this effect. 7. Insurrance of all persons working on OHR must be done by contarctor and is fully responsible for any risk involved.
All as per Serial item No. 84 above but for overhead reservoir of capacity 150000 GLNS.
All as per srl item No. 84 here-in-before but for overhead reservoir of capacity 100000 GLNS.
All as per Serial item No. 84 above but for overhead reservoir of capacity upto 50000 GLNS.
All as per Serial item No. 84 above but for Under Ground water sump of capacity 25000 GLNS.
All as per Serial item No. 84 above but for Under Ground water sump of capacity 10000 GLNS.
Material and labour for writing " Date of cleaning, numbering of water level Display and capacity of over head reservoir" on OH Reservoir of any capacity and height quite in front of entry gate of installation with white paint in English letters not exceeding 30 cm high and clearly visible with naked eyes, over black painted surface ,complete all as specified and directed.
Supply and fixing in replacement of aviation /obstruction light fitting LED 12W 240V 50Hz with light dependent senser including, fitted on GI pipe of 40 mm size and 1.0 mtr height grouted on roof of OHT complete all as specified and directed.
Supply and fixing/laying in replacement of aluminium strip of size 25x3 mm as earth continuity conductor provided in between earth test point terminal and upto the equipment incl nuts, bolts and washers complete all as specified and directed.
Supply and fixing in replacement of rigid steel conduit of 20 mm bore inclusive of all fittings such as Tees bends elbows bell mouth, tube ends reducers and all fixing accessories such as couplers, lock nuts saddles pipe hooks etc for housing of cable, fixed with suitable steel clamps at intervals of every 2 mtrs, steel screws on rawl plugs or wooden blocks complete all as specified and directed .
Material and labour for air termination single pointed aluminium rod of 12 mm dia and 300 mm long duly fixed on and including GI pipe 40mm dia 1.5 metre long, grouted on roof of OHT complete all as specified and directed.
Excavation in trenches in soft / loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out including trimming of sides complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of excavated material (soil) not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded with 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same, GI plate connected with galvanised steel strip of size 25x4 mm by means of GI nuts, bolts and washers, Strip laid in 50mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) Test point GI strip of size 25x4. (b) Watering pipe GI Medium grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 40mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.(d) Angle iron frame made of 40x40x4 mm angle iron for 30x30 mm PCC pit for holding the pit cover.Note :- The cost of excavation, earth work, watering pipe, gun metal test point, MS funnel with brass wire mesh and RCC pit with pit cover shall be deemed included in the rates. No extra cost shall be paid to the contractor against these items.
S & F, in replacement, of PVC insulated, PVC sheathed copper conductor cable of size 2.5 sqmm x 2 core laid in trenches/walls /external surfaces of over head reservoir and their stagings included rigid steel conduit of 20 mm bore inclusive of all fittings such as Tees bends elbows bell mouth, tube ends reducers and all fixing accessories such as couplers, lock nuts saddles pipe hooks etc for housing of cable, fixed with suitable steel clamps at intervals of every 2 mtrs, steel screws on rawl plugs or wooden blocks complete all as specified and directed.
M&L in repair/replacement water level indicator mechanical type with water level display and replacement of GI multistrandad wire 4 sqmm all as per existing, complete all as specified and directed.
M&L in replacement water level indicator mechanical type with water level display and replacement of Floating hollow ball of MS of size 300 mm dia all as per existing, complete all as specified and directed.
M&L in replacement three core copper conductor flat cable of size 16 sqmm complete all as specified and directed .
M&L in replacement three core copper conductor flat cable of size 10 sqmm complete all as specified and directed .
M&L in replacement three core copper conductor flat cable of size 6 sqmm complete all as specified and directed .
S&F in replacement indicator lamp RYB LED type complete all as specified and directed .
S&F in replacement voltmeter digitel LED type; 0-500V ,96mm X 96mm size complete all as specified and directed .
S&F in replacement 3 phase digitel LED type ammeter; 0-100Amp, 96mmx96mm complete all as directed
S&F in replacement on load change over switch 200 Amp 3 phase 4 pole 415 volt. Make L&T/Standard/Schneider
Supply only calcium based granule dis-infectant for water treatement more stable than chlorine gas and stronger than bleaching powder and sodium hypo chloride (Packing in 45 Kg Plastic drum) complete all as specified and directed. Make : As per approved make by HQ E-in-Cs Branch.
S & F digital soft starter, 15KW, Make L&T Cat part No. CSX 0015V4C1, for 20 HP or equivalent and approved including taking down existing old all as specified and directed complete.
S & F digital soft starter, 37KW, Make L&T Cat part No. CSX 0037V4C1, for 50 HP or equivalent and approved including taking down existing old all as specified and directed complete.
S&F in replacement of motor protection relay MPR 300 with in built earth fault protection Features: Overload, Earth fault, Locked rotor, Single phasing, Current unbalance, Phase sequence reversal, Under current, Inbuilt CT's (16A - 44A), Trip indication, Test facility Aux supply 240V AC. Make: L&T and equivalent all as specified and directed.
S&F in replacement of motor protection relay MPR 300 with in built earth fault protection Features: Overload, Earth fault, Locked rotor, Single phasing, Current unbalance, Phase sequence reversal, Under current, Inbuilt CT's (32A-88A), Trip indication, Test facility Aux supply 240 V AC. Make: L&T and equivalent all as specified and directed.
S&F in replacement of MCCB 160 amps 4 pole 25KA. Make L&T and equvaliant all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCCB 100amps 4 pole 16KA. Make L&T and equvaliant all as specified and directed by Engineer-in-Charge.
UNITED ENGINEERING CORPORATION
Sharma Electrical and Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .