Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC AT GURUDHWAR NEAR UCO BANK SOUTH BALANDA TALCHER DIST ANGUL ODISHA PIN 759116 | TALCHER | ANGUL | ODISHA | 759116 | L1 | Accepted-AOC L1 BIDDER IS TECHNO COMMERCIALLY ELIGIBLE | |
| 2 | L2₹21.1 L+₹89,322.38 (4.43%)Rejected-Finance AT TALBANDI WEST MEDINIPUR WEST BENGAL 721156 | TALBANDI | WEST MEDINIPUR | WEST BENGAL | 721156 | L2 | Rejected-Finance REJECTED AS L2 | |
| 3 | L3₹25.8 L+₹5.7 L (28.0%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L3 | Rejected-Finance REJECTED AS L3 | |
| 4 | L4₹26.3 L+₹6.1 L (30.4%)Rejected-Finance AT BUDBIJAM PO ORIENT COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L4 | Rejected-Finance REJECTED AS L4 |
Tender Value
₹27.9 L
EMD Value
₹34,900
Closing Date
5 Sept 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer(ENM), IB Valley Area
Office of Staff Officer(ENM), IB Valley Area
Dismantling, erection and diversion of 3.3 kV Overhead lines, poles of NGEF (Shovel) and siding 3 near view point along the mine boundary due to advancement of LOCP, IBVA
2023_MCL_286617_1
MCL/GM/IBV/ENM/etender/112088 Dated 21.08.2023
Open Tender
Electrical and Maintenance Works
Item Rate
60 days
LOCP, IB VALLEY AREA
Please refer Tender documents.
4 documents required · 4 mandatory
₹34,900
10 Nov 2023
21 Aug 2023
8 Sept 2023
22 Aug 2023
5 Sept 2023
22 Aug 2023
22 Aug 2023 - 25 Aug 2023
Amount
Item Description
Supply of RS joist pole 9 mtrs (150 mm X 150 mm)
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/ 33 KV as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Supplying of 8 SWG G.I. wire as required.
Erection of G.I. Wire No. 8 SWG including binding etc. as required.
Pole Transporting & loading, unloading and sacking etc as required
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and fixing of different size nuts & Bolts & Washers etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying Horizontal type 11 KV GOAB 800 A double break
Supplying Two length Channel iron 75 mm X40 mm X6 mm double pole cross arm for three wire 11 KV overhead line conductors and painting with prime and finish paint
Labour charges for installtion of all GOAB switch
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
CHITTARAJAN MAITY
M/S LIGHT PALACE
M/s BIKASH ENTERPRISES
stage.html
html • 0.04 MB
techsummary_296757.pdf
PDF • 0.20 MB
finsummary_296757.pdf
PDF • 0.27 MB
loa112088.pdf
PDF • 2.07 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .