| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 CrAccepted-AOC 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹5.1 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹5.2 Cr+₹6.4 L (1.26%)Rejected-Finance | ₹5.2 Cr+₹6.4 L (1.26%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹5.7 Cr+₹61.3 L (12.0%)Rejected-Finance | ₹5.7 Cr+₹61.3 L (12.0%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹5.8 Cr+₹67.2 L (13.1%)Rejected-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | ₹5.8 Cr+₹67.2 L (13.1%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹6.1 Cr+₹94.0 L (18.4%)Rejected-Finance | ₹6.1 Cr+₹94.0 L (18.4%) | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹6.8 L
Closing Date
6 Apr 2021, 6:00 pmClosed
Chief Engineer Udhampur Zone
Chief Engineer Udhampur Zone PO - Garhi Udhampur-182 121
PROVN OF CENTRAL CONTROL AND MONITORING SYSTEM WITH ALLIED INFRASTRUCTURE AND CONVERSION OF O/H CONDUCTORS INTO UNDERGROUND CABLES WITH ALLIED INFRASTRUCTURE AT UDHAMPUR UNDER GE (UTILITY)) UDHAMPUR
2020_MES_375066_1
87854-A/E8
Open Tender
Electrical and Maintenance Works
Lump-sum
365 days
Udjhampur
As per NIT
9 documents required · 9 mandatory
₹3,000
GE (U) Udhampur
₹6.8 L
Yes
18 May 2021
7 Sept 2020
10 Apr 2021
7 Sept 2020
6 Apr 2021
23 Mar 2021
Amount
Total Amount of Sch 'A' Part - I (Building Work)
Total Amount of Sch 'A' Part - II (Internal Electrification)
Total Amount of Sch 'A' Part - III (Road/Path/Culvert)
Total Amount of Sch 'A' Part - IV (External Electrification)
Sch 'A' Part - V (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
MCB, single pole, 6 to 32 Amp, `C' series, 10KA, 240 Volt, complete all as specified.
MCB, single pole and neutral, 6 to 32 Amp, `C' series, 10KA, 240 Volt, complete all as specified.
LED tube light 18/20/21 Watt, 4 feet with LED tube rod integrated type lP20, lumen output>95lum/w, color temp 5700-6500K, CRI>80, THD<20%, PF>0.9, operating voltage 140-270V, extruded aluminum housing in poly carbonate cover body with all accessories prewired and connecting electrically to ceiling rose, complete all as specified and directed. Make: Crompton Cat Part No. LCTL-18-CDL or technically and commercially equivalent models of Philips/Bajaj/Wipro /GE/Syska/ Surya/Havells as approved by the GE.
Ceiling fan of 1200mm sweep, 5 star rated ( as per BEE recommendations), suitable to work on single phase, AC 230 volts, 50 hz supply complete with and including down rod , PVC insulated and overall sheathed 3 core flexible copper conductor cable of size 23/0.0076 size from ceiling rose to ceiling fan and testing complete all as specified and directed.
Exhaust fan 230mm sweep with louvers, 1400 RPM, 230 volts (single phase), electrically operated 50 Hz, heavy duty metallic body complete with bolts, nuts & washers, embedded in the wall including provisioning of three core flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to Exhaust fan for connection, complete all as specified & directed.
Supply , Installation and testing of LTCT Operated Trivector Meter with the following specifications : Meter Type - 3Phase, 4-Wire LTCT Operated Trivector Meter, Applicable Standard: Latest IS-14697, IS-15959 , Accuracy Class: 0.5, Voltage and Current Rating (i) Rated Voltage 415 ± 20% ( Phase-Phase), (ii) Rated Current Ibasic : 5A, Imax : 10A, Overload Capacity: 200% of Ibasic, Frequency : 50Hz ± 5%, Power factor Range: 0Lag-Unity-0Lead, Display: 7 Digit 7 Segment LCD Display ( Min) Power Consumption (i) Potential Circuit :1.5 Watts/Phase and 8VA/Phase, Current Circuit: 1VA/Phase, Type of Energy Registration: Electronic, Modes of Operation: Auto Mode, Battery Mode : Inbuilt Primary Battery activated by push Button. Communcation Port: (i) Galvanicaly Isolated Optical Communication port for Data Transfer (ii) RS232Port for Remote Communication. Load Survey: As per IS 15959 i.e 45 days with integration period configuration 15 Minutes - 30 Minutes EMI/EMC Compliance as per IS: 14697, Self Diagnostic Feature: CT Ratio Non Programmable, The Meter shall have indication for satisfactory/non functioning/malfuctioning in the followings:- a) Time and date on meter display b). All Display segment as per the requirement under IS14697
(Srl item 11 contd) c). Non Volatile Memory status in Meter Reading HPL Cat Part No: TLPB2921131000OC00 /Siemens/L&T/secure d) GPRS Modem : It includes GSM/GPRS quad band 850/900/1800/1900 MHz for SMS alert, Maximum power Consumption 10W, LED blinking will show the live status of the device, suitable to communicate with Meter through RS232 Port , Dedicated Device ID for Each Supply Voltage :- 220 VAc/ 12-24Vdc ( Universal) Power consumption :- AC max 1W at 220 VAc, Controller :- 16 bit microcontroller, I/O :- RS 232/RS 485 ,WIFI Module Display :- LED blinking, Wireless :- Wifi Module Base, Live status :- LED Indicators, Weight : - 98 gms approx. Graphic visualization : - yes (View in web portal), Dimension :- 105x75x30 mm Communication :- Data Type Serial Bus, Print & data downloading :- By Export in Excel & Pdf .Metallic Meter Box made of suitable size MS Sheet with Legs to Tighten on Ground with suitable IP Protection for preventing Ingress of Moisture, Double Door with Partition for Cable Entry and CT at Bottom and Meters at Top having clear visibility from glass to collect readings
(srl item 12 contd) c). Occupation And Vacation Module : The system would support occupation/vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. d). Energy Accounting Module : The system would include features of energy accounting.The system would be able to account for total energy block wise, Facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. e). Communication Module: The system would provide communication of energy data and bills via print,email and SMS methods. f). Meter Master Data : The system would support meter master data repository and also will support meter replacement process. Note: Annual maintenace by OEM for software including materials should be provided by the contractor for three years after the date of completion of the work without any extra cost. The quoted rate shall be deemed to include this aspect.
Supplying, installation, testing and commissioning of manufacturer’s Factory manufactured and tested, sheet steel clad / enclosed, HT Vacuum Circuit Breaker (VCB) switchgear 11 KV, 400 Amps, 25 KA for 3 second having rupturing capacity 250 MVA ( AS INCOMER CUM OUTGOING INDEPENDENT PANEL BOARD) outdoor type, dust & vermin proof, motorised as well as manually charged, fully interlocked, horizontal draw out, horizontal isolation type, floor mounted, 11 KV, 400 Amps, PVC sleeved Copper bus-bar, 3 phase, 50 Hz, as per IEC 62271-200., extendable type complete. Manual charging system as well as AC motor charging mechanism for operation. The charging time of motor shall be less than 15 Second, making it suitable for rapid auto reclosing duty, and safety shutters shall be provided to cover up the fixed high voltage contacts on bus bar and cable side when the bus trunk is moved to test/isolation position with all standard accesssories and metering equipments and comprising of followings: (a) VCBs to be provided as "INCOMER CUM OUTGOING" (b) CTs Epoxy resin cast type (1 x 2 core or 2 x 1 core type)copper winding dual ratio, 400-200/5+5 Amps rating, class 5 P 10 for protection & class 1.0 for metering 10 VA burden, short time rating 25 KA for 3 Sec. suitable for 11 KV = 03 Nos.
(srl item 13 contd) (g) Switch for closing / tripping of VCB (h) Heater with switch , thermostat and illumination. (j) one analog type Ammeter 0-60Amps range CT operated 96x96 mm square flush type (k) 01 No shunt trip coil and closing coil 110 V DC (l) Power pack unit, 24 Volts DC with dry rechargeable batteries complete. (m) Mechanical and Electrical interlocking with existing system as directed by the GE. (n) Degree of protection - IP56 (o) Paint shade - RAL 7032 (p) Acessories : (i) Push button for trip circuit healthy check (ii) Trip neutral close switch (iii) Local remote switch (iv) Panel illumination lamp with switch (v) 3 Pin plug with switch (vi) Push button for emergency trip (vii) Push button for alarm accept (q) Auxillary power supply system of panel complete with maintainance free lead acid battery bank, mounted on 40x40x5 mm MS angle iron rack and provided with connector etc complete in all respect with installed capacity 24 volts DC 2 Nos each of 12 volts 100 AH including battery charger all as per standard specification suitable for 2x24 volts battery with DC Amp meter, voltmeter, switches ON/OFF, TRICKLE/BOOST and copper cable connection upto panels etc.
Supply, Installation, testing and commissioning of HT Panel board. consisting of 01 Nos Incomer and 02 Nos out going panel. The specification of incomer and out going panel is as under :- (A) Supplying, installation, testing and commissioning of manufacturer’s Factory manufactured and tested, sheet steel clad / enclosed, HT Vacuum Circuit Breaker (VCB) switchgear 11 KV, 400 Amps , 25 KA for 3 second having rupturing capacity 250 MVA ( 01 NOS AS INCOMING) Indoor type, dust & vermin proof, motorised as well as manually charged, fully interlocked, horizontal draw out, horizontal isolation type, floor mounted, 11 KV, 400 Amps, PVC sleeved Copper bus-bar, 3 phase, 50HZ, as per IEC 62271-200., extendable type complete. Manual charging system as well as AC motor charging mechanism for operation. The charging time of motor shall be less than 15 Second, making it suitable for rapid auto reclosing duty, and safety shutters shall be provided to cover up the fixed high voltage contacts on bus bar and cable side when the bus trunk is moved to test/isolation position with all standard accesssories and metering equipments and comprising of followings: VCBs to be provided as "INCOMING" (a) Three phase horizontal draw out type, resin cast line type potential transformer copper winding of 11KV/√3/110 V/√3, Acc.cl 110VA burden per phase, class 1.0 accuracy, connected star/star on HV side with HV & LV fuses, isolating plugs, for HV side and LV connections.
(Srl item 14 contd) (g) Heater with switch , thermostat and illumination. (h) one analog type volt meter 0-15 KV range PT operated 96x96 mm square flush type (j) 01 No shunt trip coil and closing coil 24V DC (k) Power pack unit, 24 Volts DC with dry rechargeable batteries complete. l) Mechanical and Electrical interlocking with existing system as directed by the GE. (m) Degree of protection - IP4X, (n) Paint shade - RAL 7032 (p) Acessories : (i) Push button for trip circuit healthy check (ii) Trip neutral close switch (iii) Local remote switch (iv) Panel illumination lamp with switch (v) 3 Pin plug with switch (vi) Push button for emergency trip (vii) Push button for alarm accept
(Srl item 14 contd) (B) Supplying, installation, testing and commissioning of manufacturer’s Factory manufactured and tested, sheet steel clad / enclosed, HT Vacuum Circuit Breaker (VCB) switchgear 11 KV, 400 Amps , 25 KA for 3 second having rupturing capacity 250 MVA (02 NOS AS OUTGOING) Indoor type, dust & vermin proof, motorised as well as manually charged, fully interlocked, horizontal draw out, horizontal isolation type, floor mounted, 11 KV, 400 Amps, PVC sleeves, Copper bus-bar, 3 phase, 50 Hz, as per IEC 62271-200., extendable type complete.Manual charging system as well as AC motor charging mechanism for operation. The charging time of motor shall be less than 15 Second, making it suitable for rapid auto reclosing duty, and safety shutters shall be provided to cover up the fixed high voltage contacts on bus bar and cable side when the bus trunk is moved to test/isolation position with all standard accesssories and metering equipments and comprising of followings: (a) VCBs to be provided as "OUTGOING" (b) CTs Epoxy resin cast type (1 x 2 core or 2 x 1 core type)copper winding dual ratio, 200-100/5+5 Amps rating, class 5 P 10 for protection & class 1.0 for metering 10 VA burden, short time rating 25 KA for 3 Sec. suitable for 11 KV = 03 Nos.
(Srl item 14 contd) (l) Mechanical and Electrical interlocking with existing system as directed by the GE. (m) Degree of protection - IP 4X, (n) Paint shade - RAL 7032. (p) Acessories : (i) Push button for trip circuit healthy check (ii) Trip neutral close switch (iii) Local remote switch (iv) Panel illumination lamp with switch (v) 3 Pin plug with switch (vi) Push button for emergency trip (vii) Push button for alarm accept. (q) Auxillary power supply system of panel complete with maintainance free lead acid battery bank, mounted on 40x40x5 mm MS angle iron rack and provided with connector etc complete in all respect with installed capacity 24 volts DC 2 Nos each of 12 volts 100 AH including battery charger all as per standard specification suitable for 2x24 volts battery with DC Amp meter, voltmeter, switches ON/OFF, TRICKLE/BOOST and copper cable connection upto panels etc.
Supply, Installation, testing and commissioning of HT Panel board consisting of 01 No Incomer and 03 Nos out going panel. The specification of incomer and out going panel is as under :- (A) Supplying, installation, testing and commissioning of manufacturer’s Factory manufactured and tested, sheet steel clad / enclosed, HT Vacuum Circuit Breaker (VCB) switchgear 11 KV, 400 Amps , 25 KA for 3 second having rupturing capacity 250 MVA (01 No AS INCOMING) Indoor type, dust & vermin proof, motorised as well as manually charged, fully interlocked, horizontal draw out, horizontal isolation type, floor mounted, 11 KV, 400 Amps, PVC sleeved Copper bus-bar, 3 phase, 50HZ, as per IEC 62271-200., extendable type complete. Manual charging system as well as AC motor charging mechanism for operation. The charging time of motor shall be less than 15 Second, making it suitable for rapid auto reclosing duty, and safety shutters shall be provided to cover up the fixed high voltage contacts on bus bar and cable side when the bus trunk is moved to test/isolation position with all standard accesssories and metering equipments and comprising of followings: VCBs to be provided as "INCOMING" (a) Three phase horizontal draw out type, resin cast line type potential transformer copper winding of 11KV/√3/110 V/√3, Acc.cl 110VA burden per phase, class 1.0 accuracy, connected star/star on HV side with HV & LV fuses, isolating plugs, for HV side and LV connections.
(srl item 15 contd) (h) one analog type volt meter 0-15 KV range PT operated 96x96 mm square flush type (j) 01 No shunt trip coil and closing coil 24V DC (k) Power pack unit, 24 Volts DC with dry rechargeable batteries complete. (l) Mechanical and Electrical interlocking with existing system as directed by the GE. (m) Degree of protection - IP4X, (n) Paint shade - RAL 7032. (p) Acessories : (i) Push button for trip circuit healthy check (ii) Trip neutral close switch (iii) Local remote switch (iv) Panel illumination lamp with switch (v) 3 Pin plug with switch (vi) Push button for emergency trip (vii) Push button for alarm accept
(srl item 15 contd) (B) Supplying, installation, testing and commissioning of manufacturer’s Factory manufactured and tested, sheet steel clad / enclosed, HT Vacuum Circuit Breaker (VCB) switchgear 11 KV, 400Amps , 25 KA for 3 second having rupturing capacity 250 MVA ( 03 NOS AS OUTGOING) Indoor type, dust & vermin proof, motorised as well as manually charged, fully interlocked, horizontal draw out, horizontal isolation type, floor mounted, 11 KV, 400 Amps, PVC sleeves, Copper bus-bar, 3 phase, 50 Hz, as per IEC 62271-200., extendable type complete.Manual charging system as well as AC motor charging mechanism for operation. The charging time of motor shall be less than 15 second, making it suitable for rapid auto reclosing duty, and safety shutters shall be provided to cover up the fixed high voltage contacts on bus bar and cable side when the bus trunk is moved to test/isolation position with all standard accesssories and metering equipments and comprising of following: (a) VCBs to be provided as "OUTGOING" (b) CTs Epoxy resin cast type (1 x 2 core or 2 x 1 core type)copper winding dual ratio, 200-100/5+5 Amps rating, class 5 P 10 for protection & class 1.0 for metering 10 VA burden, short time rating 25 KA for 3 Sec. suitable for 11 KV = 03 Nos.
(srl item 15 contd) (l) Mechanical and Electrical interlocking with existing system as directed by the GE. (m) Degree of protection - IP 4X, (n) Paint shade - RAL 7032. (p) Acessories : (i) Push button for trip circuit healthy check (ii) Trip neutral close switch (iii) Local remote switch (iv) Panel illumination lamp with switch (v) 3 Pin plug with switch (vi) Push button for emergency trip (vii) Push button for alarm accept (o) Auxillary power supply system of panel complete with maintainance free lead acid battery bank, mounted on 40x40x5 mm MS angle iron rack and provided with connector etc complete in all respect with installed capacity 24 volts DC 2 Nos each of 12 volts 100 AH including battery charger all as per standard specification suitable for 2x24 volts battery with DC Amp meter, voltmeter, switches ON/OFF, TRICKLE/BOOST and copper cable connection upto panels etc. Notes for Srl item No 13 to 15: Refer Srl Note No 24 of Schedule `A' (BOQ) Notes for Srl item No 13 to 15
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV (E) grade, size 150 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole or drawing through existing trenchless boring complete all as specified and directed. Notes:- (a) Earth work, PCC covers and sand cushioning shall be measured and paid for separately. (b) The Quoted rates shall be deemed to include the following:- (i) Colour code of HT cables shall be as per standard IS. (ii) Pre dispatch Inspection of HT cables shall be carried out at manufacturer's factory by rep of Accepting officer before despatching to site. (iii) Cable shall be marked or embossed as ''GE(U) Udhampur" at every one metre length .
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV (E) grade, size 120 Sqmm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole or drawing through existing trenchless boring complete all as specified and directed. Notes:- (a) Earth work, PCC covers and sand cushioning shall be measured and paid for separately. (b) The Quoted rates shall be deemed to include the following:- (i) Colour code of HT cables shall be as per standard IS. (ii) Pre dispatch Inspection of HT cables shall be carried out at manufacturer's factory by rep of Accepting officer before despatching to site. (iii) Cable shall be marked or embossed as ''GE(U) Udhampur" at every one metre length .
Air break isolating switch triple pole mechanically operated with vertical isolation, 12 insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm bore GI pipe medium grade and locking arrangement of capacity 400 Amps 11 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and overhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Air break isolating switch triple pole mechanically operated with vertical isolation, 9 insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm bore GI pipe medium grade and locking arrangement of capacity 400 Amps 11 KV without drop out fuse set including making all incoming/outgoing connection of HT cable and overhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Cable jointing kit for 11 KV (E) grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Cable jointing kit for 11 KV (E) grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Heat shrinkable straight through cable jointing kit for 11 KV (E) grade cable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and as directed.
Steel tubular swaged poles type 410 SP-55 (11.0 Mtr long) , IS-2713 marked, with mild steel base plate (fillet welded to poles), pole cap / finial taper plug, bolts, nuts, washers etc, painting on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embeded in concrete and painting 03 Nos band /strips with fluorescent PO box red synthetic enamel paint ( 30 cm wide each) at a distance of 30 cm from plinth block and numbering of poles, complete all as specified and directed. Note: Excavation, earth work and PCC shall be measured and paid for separately
Road cuttig existing road for crossing of underground electric cable for laying of any size GI tubing/Concrete pipes including necessary excavation and earth work including repairing the same as per existing with and including pre mix bituminious carpet complete all as specefied and as directed by Engr-in-charge.
XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laind in trenches or passing through pipe or fixed on poles complete all as specefied and directed by Engr-in-Charge.
Cable route indicator made out of MS bar 8mm of size 90cmx35cmx50mm complete duly marked as (HT 11KV UG cable) duly embedded in PCC 1:2:4 including excavation and earthwork, complete all as specified and as directed by Engineer-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 25 watt with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment and impact resistance of IK07 with high efficiency long life LED with SMD LED on MCPCB powered by BUILT-IN, isolated electronic LED driver (SMPS based constant current supply) complete including GI bracket and making connection as directed.
Deduct amount of Credit Schedule Rs 4,46,590.00 as listed in Schedule 'A' Part-VI Lumpsum contract sum shall be arrived at after deducting the Credit Schedule amount. Note: Tenderers will not quote against this item being firm amount.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .