Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
27 Oct 2026, 12:30 pm
Chief Manager Works
Proposed Construction of First Floor above Existing Building for Conference Room including Civil Electrical and Air conditioning Works at RWRDC Division HAL Bangalore
TENDER NOTICE/NCP/61/26-27::HAL/FMD/C-60/26-27
TENDER NOTICE/NCP/61/26-27
Open Tender
Works
08MONTHS
Contract Section Civil-FMD-Bangalore
Refer Tender Document
₹0
₹2.6 L
29 Sept 2026
29 Sept 2026
27 Oct 2026
27 Oct 2026
6 Oct 2026
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Year of Estblishment of Company/Business
If Other, please specify
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, etc.,
Address for correspondence:
PAN no and Name of Holder
PF number (If any)
ESI number
Goods and Service Tax ID No.
Contact details
Registered Contractor
Pls Enter
I.T Returns for past 03 assessment years
Turnover during the following 5 years (In Rs. Lakhs)
Pls enter Finiancial Turnover in Rupees Lakhs for all the years
DETAIL OF WORK ON HAND UPTO N-Months (N-contract period) [For Bid capacity calculation] NOTE : CA certified statement as per below format to be uploaded.
Name of Organization with address
Work Schedule for completion of works with in stipulated time [Please enclose action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)]
Bank(s) details: [Copy of ECS and cancelled cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Bank Statement for past three month
Latest Overdraft Facilties with Bank enter Name of Bank, Date of Issue and Value of Over Draft
Solvency Certificate Details
Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender. [Work experience certificates / Completion certificates should be uploaded for verification]. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of the estimated cost. [Amount put to the Tender]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Type of Work and Organisation name [ Incase of private works the same shall be supported with TDS certificate]
Related Document to be Uploaded to eProcurement Portal
DEAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficant separate sheet to be uploaded with the same format as below)
Name of members or technical personllel avalable in the organization
DETAILS OF MACHINERY AVAILABLE
Name of Mechinery
Concrete Mixers - Type etc
Vibrators - Diesel - Electrical
Weiding equipment's
a) Rectifiers
b) Welding Generators
Erection equipment's
Cranes-
Hoists-
Lifts-
Water Lifting motor pumps
a) Diesel
b) electric
Drilling Equipment's
Compressors
Trucks
Stone crushers
Bitumen hot mixture plant
Bitume boiler
Rollers
Batching plants
Vibratory rollers
Generators
Cranes-Details
Concrete pumps
Road Pavers
Rock breakers
Transit mixers
Excavators
Weight batches
Others
DECLARATION
Pls enter
EMD details
Enclosed / Not enclosed
Enclosed
Average annual financial turn over during the last 3 years, ending 31st March 2025 and details for last 5 years to be provided to assess the bid capacity. The values provided to be supported by uploading Balance Sheet along with Profit & loss account (In Rs. Lakhs)
Specification
Demolishing RCC work / dummy columns, parapet concrete, chajja, etc., manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead, etc., all complete as directed by Engineer-in-Charge.
Demolishing brick work built in cement motor manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead, etc., all complete as directed by Engineer-in-Charge.
Demolishing brick bat water proofing layer including felt / membrane of bitumen, etc., in terracing and disposal of material within 50 metres lead, etc., all complete as directed by Engineer-in-Charge.
Dismantling doors of area not exceeding 3 Sq m, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts, etc., complete and stacking within 50 metres lead, etc., all complete as directed by Engineer-in-Charge.
Dismantling steel work in single sections built in channels, angles, tees, flats, etc., including dismembering and handing over to maintenance department / salvage yard, etc., all complete as directed by Engineer-in-Charge.
Dismantling roofing including ridges, hips, valleys and gutters, etc., and stacking the material as disposal unserviceable material outside the presmises of within 50 metres lead of made out of Asbestos Cement Sheeting, etc., all complete as directed by Engineer-in-Charge.
Dismantling CI / GI /PVC Pipes or asbestos rain water pipe with fittings and clamps upto 150mm including stacking the useful material at Maintenace Department and disposal of unserviceable material outside the premises of HAL, etc., all complete as directed by Engineer-in-Charge.
Dismantling tile work in floors and roofs, upto 25mm tile thickness laid in cement mortar including stacking material within 50 metres lead, etc., all complete as directed by Engineer-in-Charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved, etc., all complete as directed by Engineer-in-Charge.
Disconnecting overhead / terrace PVC water storage tank of any size / capacity from water supply line and removing from the terrace including shifting at ground level, etc., all complete as directed by Engineer-in-Charge.
Dismantling doors, windows / ventilators and clerestory windows (steel or wood) shutter including chowkhats, steel frames, grills, glass, architrave, holdfasts andother fixtures, etc., complete and stacking within 50 metres lead of area 3 Sq m and below, including stacking material and handing over the useful materials to HAL maintenance department and disconnecting the service lines if any, etc., all complete as directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas in all kinds of soft / hard soil for foundations, footings, column pedestals or members as per the drawing or as per directions of EIC, etc., (exceeding 30 cm in depth, 1.50m in width as well as 10 Sq m on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50m for all lifts with all labour, tools & tackles, plant & machinery, hire & fuel charges, etc., all complete as directed by Engineer-in-Charge.
Removing / transporting the surplus excavated earth including debris, vegetation waste, concrete waste, etc., to a distance upto 5000m from HAL premises to contractor's own yard including loading, unloading, depositing, spreading, levelling etc, all complete as per directions of Engineer-in-Charge.
Returning / Filling in available useful excavated earth (excluding rock) free from salts, organic or other deleterious matter (Other than black cotton soil & rock etc.,) in trenches, plinth, sides of foundations, etc., in layers not exceeding 20cm in depth, consolidating each deposited layer by watering, breaking / removing clods exceeding 50mm, ramming and consolidation, etc., with all labour, tools & tackles, plant & machinery, etc., lead up to 50m and lift upto 1.50m, etc., all complete as directed by Engineer-in-Charge.
Providing, mixing and laying in position cement concrete (1:4:8) derived from natural sources of required thickness using 40mm down graded hard stone / granite aggregate in accordance with IS 456 in all works up to plinth level, including mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions, etc., all complete as directed by Engineer-in-Charge.
Making Plinth Protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc., all complete as directed by Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:2:4) of required thickness using 20mm nominal size down graded hard stone / granite aggregate in accordance with IS 456 in Cills, fillets, coping,etc upto floor five level, including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions, etc., but excluding the cost of centering, shuttering and finishing, etc., all complete as directed by Engineer-in-Charge.
Providing and laying in position cement concrete for all work up to plinth level including flooring of 1:2:4 (1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources), etc., all complete as directed by Engineer-in-Charge.
Providing and laying in position ready mixed or site batched M25 Grade with minimum cement content of 350 kg/m3 design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts but excluding the cost of centering, shuttering, finishing and reinforcement, etc., all complete as directed by Engineer-in-Charge. Note: (i) Site design mix to be obtained from Govt. / NABL laboratory for site batching concrete. (ii) Small quantity is as approved by EIC in volumetric proportion.
All works upto plinth level including necessary openings and packing if any for laying pipes, cables, etc.,
All works above plinth level upto floor V level including necessary openings and packing if any for laying pipes, cables, etc.,
Formwork (Centering and shuttering including strutting, propping etc., and removal of form) for the following RCC members which are defined as below, in fair finished by providing timber, wooden planks, runners / MS sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including MS bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete, etc., all complete as directed by the Engineer-in-Charge for the sub-items mentioned below. Note: Formwork material is contractor's own property and shall be removed after completion of work.
Foundations, footings, bases of columns, bed concrete, ramp concrete, pedestal, etc., for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses, etc.,
For Roofs, landings, suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks, etc., at suspended height 3.60m and below.
For Roofs, landings, suspended floors, Slabs supported on walls, roofs, landings, balconies, access platforms, Gutters, decks, etc., at suspended height of around 4.20m - 4.50m height.
Plinth beams, Lintels, Beams, room beams, beams, girders, bressumers and cantilevers, etc.,
For Columns, Pillars, Piers, etc.,
For Stairs (excluding landings ) except spiral -stair case.
Chajja, Weather shade, Canopies, Corbels, etc., including edges
Edges of slabs and breaks in floors and walls under 20cm wide
Supplying, straightening, fabricating (cutting & bending), placing in position and binding steel reinforcement of TMT bars of not less than Fe 500 D conforming to IS 1786 for all concrete reinforcment members / works above / below plinth level, including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.90mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it, etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note: a) Only authorized laps, chairs etc. shall be considered for measurement. b) The exposed Reinforcement bars shall be coated with cement slurry.
Providing and fixing MS grills of required pattern to steel windows / walls / in frames of windows, ventilators, etc., and approved design using MS structurals such as MS flats, angles, round / square bars, etc., including necessary cutting, welding, embedding in concrete, masonry, etc., including priming coat with approved steel primer, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing stainless steel (Grade 304) railing of approved size / design by welding, etc., made of Hollow tubes, channels, plates, etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts, etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-Charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners, etc.), etc., all complete as directed by the Engineer-in-Charge.
Construction of Stone masonry (first sort) in cement mortar (1:6) (1 cement : 6 coarse sand) with hard stone, solidly hearted faces, beds and joints squared back, in foundation and below plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level, raking out joints 10mm deep, curing, providing weep holes if any, etc., all complete as directed by the Engineer-in-Charge. Note: Item to be used for UPS room foundation.
Providing and laying factory made Precast concrete solid blocks built in CM (1:6) and of 200mm thickness of grade M10 made of Normal resources / C & D Waste from approved manufacturer in superstructure above plinth level up to floor V level, etc., all complete as directed by the Engineer-in-Charge.
Providing and laying half block masonry with factory made Precast concrete solid blocks built in CM (1:4) and of 100mm thickness of grade M10 made of Normal resources / C & D waste from approved manufacturer in superstructure above plinth level up to floor V level, etc., all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 12mm thick cement plaster work in for internal / External areas of Ceilings, Chajjas, etc., in CM (1:4) including forming grooves not exceeding 10mm wide and not exceeding 10mm deep as per requirement as directed including preparation of surface by hacking, etc., at all levels with necesary materials, labour, scaffoldings, curing, tools and tackles, plants, etc., threading if any as directed, etc., all complete as directed by the Engineer-in-Charge.
Providing, applying and laying cement mortar (1:6) plastering 15mm thick on brick / solid blocks / concrete surfaces, finished even and smooth with trowel for Internal / External walls, etc., including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & brick work or between different material, including making grooves as per the requirement not exceeding 10mm width and not exceeding 10mm deep with necesary materials, labour, scaffolding, curing, tools and tackles, etc., at all heights, etc., all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 18mm thick cement plaster work in two coats for external areas as directed. First coat 12mm thick in cement mortar (1:5) made rough to recieve top coat, second coat 6mm thick in cement mortar (1:6), final surface finished with a floating coat of neat cement after necessary preparation of surface, at all levels including supply and fixing of hexagonal chicken mesh minimum 150mm wide having opening [20 x 20]mm of 26 gauge at juncitons of concrete & brick work or between different material, with necesary materials, labour, scaffoldings, curing, tools and tackles, plants, etc., threading if any as directed, etc., all complete as directed by the Engineer-in-Charge.
Painting newly plastered external surfaces with two or more coats applied at 1.43 litre / 10 Sq m / as per manufacturer specifications of 100% premium acrylic emulsion paint having VOC less than 50 grams / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint with silicon additives of approved make, colour, shade, tint & pattern at all levels, over and including a coat of approved acrylic primer including preparing the surface by removing loose dirt and any organic growth, filling of cracks, necessary scaffolding, etc., all complete as directed by the Engineer-in-Charge. Note: The paint shall have anti-algal, anti-fungal, UV resistant & anti-tarnishing qualities with 100% acrylic base and silicon or elastomeric additives.
Painting Steel surfaces of any description with two coats of synthetic enamel paint of approved colour, brand and manufacture to give an even shade, including preparation of surface by rubbing with fine grade of abrasive paper to ensure smooth, etc., all complete as directed by the Engineer-in-Charge.
Painting newly plastered interior surfaces with two coats of premium acrylic emulsion paint of interior grade having VOC (Volatile Organic Compound) content less than 50 grams / litre conforming to IS 15489, of approved make, brand, colour and texture, shade, tint, manufacture & pattern at all levels including non-reflective paint whereever required, etc., including preparing the surface by removing loose dirt and any organic growth, smoothening the surface by using suitable emery paper, filling crevices and finishing even and smooth by providing and applying white cement based putty of suitable thickness in 2 coats of approved brand and manufacture over the plastered wall surface and followed by the applying priming coat with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on applied putty having VOC content less than 50 grams / litre, necessary scaffolding, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite stone slab of colour black, Cherry / Ruby red and area of slab over 0.50Sq m for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish, etc., complete at all levels, as directed by the Engineer-in-Charge.
Providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, pantry, vanity counter, wash area and similar location in marble / Granite / stone work, including necessary holes for pillar taps, etc., including moulding, rubbing and polishing of cut edges, etc., all complete as directed by the Engineer-in-Charge.
Providing and laying Polished Granite stone flooring slab of colour Black, Cherry / Ruby Red or equivalent in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, etc., all complete as specified and as directed by the Engineer-in-Charge.
Providing and fixing Ceramic glazed wall tiles / Vitrified tiles / Anti skid / Matt finished conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and set & jointing with neat grey cement slurry @ 3.30kg per Sq m, including pointing in white cement mixed with pigment of matching shade complete, including machine cutting, curing, etc., all complete as directed by the Engineer-in-Charge. Note: Quoted rate shall be inclusive of screed, pointing, etc.,
Providing and laying Double Charged vitrified floor tiles polished finish size of tile Size of [600 X 600]mm or nearest available size in floors over a screed of cement mortar (1:4) 20mm thick for Paper Joint (Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.30 Kg/Sq m including grouting the joints with white cement and matching pigments, etc., all, complete as directed by the Engineer-in-Charge.
Providing and laying Glazed vitrified tiles Matt / Anti skid polished finish size in floors as indicated below for Paper Joint of tile size of [600 X 600]mm (Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.30 Kg/Sq m including grouting the joints with white cement and matching pigments, etc., all, complete as directed by the Engineer-in-Charge. Note: Quoted rate shall be inclusive of screed, pointing, etc.,
Providing and laying Vitrified tiles in Skirting over a screed of cement mortar (1:3) - Size of Tile [600 x 600]mm or nearest size available (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.30 kg/Sq m including grouting the joint with white cement & matching pigments, etc., all, complete as directed by the Engineer-in-Charge.
Supplying, fabricating and fixing second class teak wooden plain, solid, straight chowkats and frames of doors, windows, partitions, wall panelling frames and other frames, wrought framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed to wall or in position with hold fast lugs or with dash fasteners of required dia & length, etc., all complete as directed by the Engineer-in-Charge. Note: Hold fast lugs or dash fastener shall be paid separately.
Providing, fabricating and fixing 35mm thick flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25mm minimum depth on all edges and well matched commercial 3ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges with necessary screws and face veneers on both faces of shutters and provision of rebates, suitable blocks for taking mortice locks, latches or other fittings, fitting to frames / chowkats, etc., all complete as directed by the Engineer-in-Charge. Note: Fittings / hardware shall be paid separately.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames / Chowkhat of size [45 x 70]mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/Cu m, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water / moisture proof and fire retardant and fixed in position with M.S hold fast / lugs / SS dash fasteners of required dia and length, etc., all complete as directed by the Engineer-in-Charge. Note: For WPC solid door / window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter (minmum 30mm thick) of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder / rice husk / wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/Cu m and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite / borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, etc., all complete as directed by the Engineer-in-Charge.
Providing [40 x 5]mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block [30 x 10 x 15]cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size), etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc, all complete as directed by the Engineer-in-Charge.
Providing and fixing bright finished brass 100mm mortice latch and lock of 6 levers, vertical type, and a pair of lever brass handles of approved quality, polished bright of approved manufacture to door with all necessary screws, bolts, nuts and washers of approved manufacture, etc., all complete as directed by Engineer-In-Charge.
Supplying and fixing the Polished (bright finished) brass barrel type tower bolts 250mm long X 10mm with barrel of extruded sections of brass, of approved make and rolled or drawn brass bolt, design to door with all required screws, bolts, nuts, washers, etc., conforming to IS 204 (Part 2), etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing 20mm dia chromium plated brass curtain rod / Towel rail of 600mm long having wall thickness of 1.25mm with two chromium plated brass brackets fixed with CP brass screws and PVC sleeves etc., wherever necessary, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing bright finished brass butt hinges [125 X 70 X 4]mm with necessary screws, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kgs to 80 kgs and door width from 701mm to 1000mm), with double speed adjustment with necessary accessories and screws, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine, etc., with auto closing spring loaded hinges (hydraulic type), etc., all complete as directed by the Engineer-in-Charge. (Payment of providing and fixing auto closing hinges shall be paid separately)
Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS : 710 of approved brand boxes, shelves, racks, almirah, cupboard and drawer, etc., including necessary nails, screws, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make / brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing 200mm stainless steel fancy handle D-Type of approved make fixed with all accessories like flanges, SS screws, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500mm long with screws, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel, etc., all complete as directed by the Engineer-in-Charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts,bolts, fasteners telescopic basket channels, etc., Payment of providing and fixing telescopic channel shall be paid separately)
Providing, fixing, testing and commissioning single socketed pipes of 75mm dia, on wall face / in floors unplasticised Rigid PVC rain water pipes of 6 kg/cm² SWR grade and of approved make conforming to IS : 13592 Type A, including jointing together with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion and all necessary fittings & specials, bends, branches, sockets, clamps, pipe cutting and wastages, cutting and making good the walls / floors, connecting to existing lines, etc., all complete as directed by the Engineer-in-Charge.
Providing, fixing, testing and commissioning single socketed pipes of 110mm dia, on wall face / in floors unplasticised Rigid PVC rain water pipes of 6 kg/cm² SWR grade and of approved make conforming to IS : 13592 Type A, including jointing together with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion and all necessary fittings & specials, bends, branches, sockets, clamps, pipe cutting and wastages, cutting and making good the walls / floors, connecting to existing lines, etc., all complete as directed by the Engineer-in-Charge.
Supplying, Laying and compacting of granular sub-base in flooring, subbases, ramps, etc., upto plinth level of requisite grading by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board as per IS:13983 and of approximate size of [510 x 1040]mm bowl depth 250mm with CI brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing White Vitreous China counter sunk type Wash basin of size [630 x 450]mm or nearest available size of approved make with a pair of 15mm CP brass pillar tap of approved model & make, CI brackets, 32 mm C.P. brass waste fitting, 32 mm dia semi-rigid PVC waste pipe, including painting of fittings and brackets, cutting and making good the walls, connecting to floor trap and with all necessary fittings and accessories, etc., wherever require, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings, along with all the necessary fittings, fixtures and other accessories including PVC waste fitiings, PVC semi rigid type waste pipe, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing white vitreous china pedestal type water closet (European type WC pan) WC pan with ISI marked white solid plastic seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing, testing and commissioning 8mm dia CP / SS Jet (health faucet) with flexible tube upto 1 metre long with SS triangular plate to Eureopean type WC of quality and make as approved with necessary fittings, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing of toilet paper holder of CP brass type, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing of ball valve (brass) 25mm nominal bore dia of approved quality, High or low pressure, with plastic floats, screwed for iron pipe or brass ferrule and fixed including necessary fittings i.e flynut, etc., all complete as directed by the Engineer-in-Charge.
Providing and placing in position at terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes along with necessasry accessories, etc., all complete as directed by the Engineer-in-Charge.
Supplying, jointing, testing and commissioning, approved make GM body gate valves with CI wheel and screwed ends, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing PTMT angle stop cock 15mm nominal bore, weighing not less than 85 gms fixed to the health faucet, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing CP brass bib cock of 15mm nominal bore dia and approved quality conforming to IS:8931, etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing Concealed Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, fixing the pipe with clamps at 1m spacing, necessary reducers, tank adaptors, etc., This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and making good the walls, etc., all complete as directed by the Engineer-in-Charge.
15 mm dia
20 mm dia
25 mm dia
Providing and fixing 40mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints, etc., all complete as directed by the Engineer-in-Charge.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends Inside dimensions of approximate size [600 x 850]mm and 90cm deep for pipe line with three or more inlets with common burnt clay FPS (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) CI cover with frame (light duty) [455 x 610]mm internal dimensions, total weight of cover with frame to be not less than 38 kgs (weight of cover 23 kgs and weight of frame 15 kgs), RCC top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete, etc., complete as per standard design, all complete as per the drawings and the directions of Engineer-in-Charge.
Providing and laying integral cement based water proofing treatment With average thickness of 120mm and minimum thickness at khurra as 65mm including preparation of surface as required for treatment of roofs, (a) Applying a slurry coat of neat cement using 2.75 kgs/Sq m of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge over 20mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/Sq m of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of [300 x 300]mm square 3mm deep.
Providing and fixing mineral fibre false ceiling tiles With 16mm thick beveled tegular mineral fibre false ceiling tile (dune Max Variety) at all heights of size [595 X 595]mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance of 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7) in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33mm thick (galvanized @120 gsm) comprising of main T runners of [15 x 32]mm of length 3000mm, cross T of size [15 x 32]mm of length 1200mm and secondary intermediate cross T of size [15 x 32]mm of length 600mm to form grid module of size [600 x 600]mm suspended from ceiling using galvanized mild steel item (galvanised @ 80gsm) 50mm long 8mm outer diameter M-6 dash fasteners, 6mm diameter fully threaded hanger rod up to 1000mm length and L-shape level adjuster of size [85 x 25 x 2]mm, spaced at 1200mm centre to centre along main ‘T’. The system should rest on periphery walls / partitions with the help of GI perimeter wall angle of size [24 x 24 X 3000]mm made of 0.40mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall SS screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the Engineer-in-Charge.
Providing and fixing false ceiling (using 12.50mm thick tapered edge gypsum moisture resistant board) at all heights including providing and fixing of frame work made of special sections, power pressed from M.S.sheets and galvanized with zinc coating of 120 gms / Sq m (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.60mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.50mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of [25 x 10 x 0.50]mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate GI channels [45 x 15 x 0.90]mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.50mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.50mm, at 450mm centre to centre, shall be fixed in a direction perpendicular to GI intermediate channel with connecting clips made out of 2.64mm dia x 230mm long GI wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size [3.50 x 25]mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended
Providing and fixing of aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge for Semi Unitized System with use of minimum Vertical MULLION of section 81.16mm X 67mm X 1.80mm and Horizontal TRANSOM 81.16 mm X 67mm X 2mm with Al Cleats fixed with anchor bolts of M [10 X 9] and 8mm SS Bolts 8mm. The aluminium profiles shall be supplied with protective tapes and to be removed after completion of the work, etc., all complete as directed by Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws, etc., necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing with 6mm thick Single Reflective Heat Strengthened from approved make of Glass (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including [Glazing Only will be paid in this section of work. However, the submission of Design and Design Basis Reports is part of the specification for Semi Unitized Glazing System Please Refer details indicated below:]
Manufacturing, providing and fixing factory made UPVC glazed Fixed window / Ventilator with / without mullion / transom comprising of lead free uPVC multi-chambered frame, sash and mullion / coupler (where ever required) extruded profiles having minimum wall thickness of minimum 1.70mm for series R1, R2 profiles and minimum 2.10mm for series R3, R4 profiles with frame sizes as mentioned below, glazed, conforming to EN: 12608 in any shape, white colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware, if required and drainage of water, etc., After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, etc., all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.
Approximate size [0.60 x 0.45]m
Approximate size [1.50 x 1.20]m
Approximate size [0.60 X 0.45]m
Manufacturing, providing and fixing factory made UPVC glazed Casement windows / ventilators with / without fixed panel, single or double panel, with or without fixed / frenhmullion. If required as per the design comprising of lead free uPVC multi-chambered frame, sash and mullion / coupler (where ever required) extruded profiles having minimum wall thickness of minimum 1.70mm for series R1, R2 profiles and minimum 2.10mm for R3, R4 profiles with frame sizes as metioned below, glazed confirming to EN:12608 in any shape, white colour and design duly reinforced with galvanised mild steel section made of required shape & size as per CPWD specification, uPVC extruded glazing beads, interlocks and inlines slash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS304 grade fasteners of minimum (zamak) 8mm dia with countersunk head comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS-1367:Part1 to 14, plastic packers, plastic caps, zinc alloy powder coated handles, suitable locking system and necessary stainless steel screws, etc., Profile of frame, sash & mullion shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners (if required as per site condition), including drilling of holes for fixing hardware, to drain water, etc., After fixing the frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved quality, etc., all complete as per the direction of Engineer-in-Charge. Note:- The rate is including fixing of min 5mm clear toughened Glass as per the design requirements and as directed by EIC / OIC. Glazing to be frosted / provided with sun control film as per site requirement as directed by EIC.
approximate dimension of [1.50 x 1.20]m
approximate dimension of [1.50 x 1.50]m
Wall Panelling for conference Room with design sound proof panels
Providing and fixing laminated toughened glass door with sandwich fabric (minimum 12mm thick after lamination), including top and bottom pivots for smooth operation in 180degree operational, suitable lock with two set keys. The rate quoted shall be all inclusive of 2Nos handles of 300mm long, etc., all complete as directed by Engineer-in-Charge. Note: Agency should take exactt size of opening before placing order as approved by EIC.
Rupees Eighty Five Lakh Ninety Six Thousand One Hundred Forty and Fifty Six Paise Only
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector.
Supplying, Installation, Testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high performance, non regulating programmable type, suitable for connected load upto 10Amp, for mounting height up to 3 meter and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. The sensor shall be fully compatible with the proposed LED lighting fixtures and their control/driver system.The PIR sensors shall be the same OEM approved manufacturer as the LED light fixtures.
Supply, fixing directly to the ceiling/wall using suitable mounting arrangements testing & commissioning of surface mounting Decorative type 10W LED mirror light fitting, including driver, the driver shall have PF >0.9 and Colour temprature shall be ≥5700K, THD <20% operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections complete in all respect and as directed by EIC. The lighting fixture shall be Havells:LUMILINENXTBS10WLED830SPCHW/Equivalent make in other approved makes.
Supply, installation, testing and commissioning of 10W Two-way Wall Washer light fitting with powder coated premium aluminium body including driver, the driver shall have PF >0.9 and Colour temprature shall be >=4000K, Lumen output 850 lumen ,IP44 rated THD <20% operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections complete in all respect and as directed by EIC. The lighting fixture shall be of Philips model no:582009 /Equivalent make in other approved makes.
Supply, fixing directly to the ceiling/wall testing and commissioning of 10W LED bulkhead light fitting with die cast aluminium body with Poly carbonate front cover, including driver, the driver shall have PF >0.9 and Colour temprature shall be >5600K, IP65 rated THD <20% operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures complete in all respect and as directed by EIC. The lighting fixture shall be of Crompton model no: LBHE-10-WW/Equivalent make in other approved makes.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
Supply, installation, testing & commissioning of Industrial type heavy duty Exhaust Fan (1 phase) of 300MM dia,1400 RPM of any approved make with louvers, connecting cord with 6/16A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 400 mm dia wall mounted swing type fan of any approved make, connecting cord with 6A, 3 pin plug top and with all necessary accessories complete in all respects and as directed by Engineer-in-charge.
Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, ceiling rose, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to three light point controlled by 1 No 6A, 250V gr. flush modular type SP switch complete in all respects.
Wiring to exhaust/wall mounting fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects.
Supplying and fixing following suitable size GI/PVC Box with modular plate and cover on front on surface or in recess, including providing and fixing 3 pin 5/6A modular socket outlet and 5/6 A modular switch, connections etc., as required.
Supplying and fixing following suitable size GI/PVC Box with modular plate and cover on front on surface or in recess, including providing and fixing 6 pin 5/6A & 15/16A modular socket outlet and 15/16 A modular switch, connections etc., as required.
Supplying and fixing following suitable size GI Box with modular plate and cover on front on surface or in recess, including providing and fixing 3 pin 2X5/6A modular socket outlet and modular switch, connections etc., as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire(DB to switch box)
2 x 4 sq. mm + 1 x 4 sq. mm earth wire(For 6A & 16A Sockets)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20MM PVC Conduit
25MM PVC Conduit
Supplying and fixing following Size Modulas, GI box alongwith modular base & cover plate for modular switch in recess et.as required.
1 or 2 Module
3 Module
Telephone
Supply, Fixing, in the existing GI /PVC box as per site requirement, testing & Commissioning of 1 No. Twin RJ-11 telephone socket outlets with shutter with necessary interconnections complete as directed by Engineer-in-charge.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.At Modular table(office-1, 2 & 3)
Supply & drawing of 0.5 mm dia copper conductor PVC insulated 4 pair colour coded and twisted unarmoured telecommunication cables in the existing PVC conduit as per standard practice including necessary inter connections & end terminations.
Supply & fixing on wall/grouted to floor upto 1200mm above ground level as per site requirement using suitable size MS angle iron frame work finished with two coats of enamel spray paint over a good primer & providing 20 pair krone type telephone connector junction box including krone connector with necessary mounting frame housed in suitable size FRP/SMC box with hinged lockable cover complete in all respects and as directed by Engineer in-charge.
Supply, laying in the already excavated cable trench/existing duct/fixing on wall/cable tray/iron structure using suitable clamps etc./ encasing in pipe, testing and commissioning of 10 pair jelly filled armoured copper conductor of 0.5mm dia polyethylene insulated cover, twisted into pairs, colour coded, pairs laid up, fully filled with petroleum jelly as a moisture barrier, core wrapped with non-hygroscopic polyester tape to contain the jelly, covered with aluminium poly-laminates screen, polyethylene sheath extruded over aluminium screen, polyethylene tape over the above sheath, armoured with galvanised steel tape and outer polyethylene sheath underground telecommunication cable including both end terminations on the existing krone type junction box complete in all respects.
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement including with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
8 way (4 + 24), Double door
6 way (4 + 18), Double door
5A to 32A SP MCB 10kA , C Curve
5A to 32A FP MCB 10kA , C Curve
40-63 amps. ratings, FP MCB, "C" curve, 10 KA breaking capacity.
Supply, Fixing in flush with wall/on Aluminium partition as per site condition, testing & Commissioning of 2 nos of RJ-45 modular type sockets for Data points including supply of suitable size modular MS/PVC surface mounting box with base plates, glossy finish front covers, labelling etc., with necessary interconnections and chipping the wall, replastering to smooth finish etc., wherever required complete as directed by Engineer-in-charge.
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required.
1 Run of cable
Supply and fixing on wall/ partition wall using necessary mounting arrangements for 105x50mm size DLP-PVC adaptable trunking system with separation partition for laying power and Data/Telephone cables/wires with full top cover, necessary accessoires such as end caps, flat angle, T joints, external/internal angle, flat junction, Body joint, cover joint, required cabling accessories etc., complete in all respects as directed by Engineer-in-charge.
Supply & laying in the already excavated cable trench/cable tray/fixing on wall/duct wall with necessary M.S clamps / encasing in pipes etc., testing & commissioning of following size XLPE insulated Aluminium (Al) conductor(stranded) 1.1 KV grade confirming to IS: 7098 ( part-I)/1998 with upto date amendment earthed Armoured (Arm)U.G cables and as per technical specification including stacking at site, proper storage complete etc., as required. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
4CX 16 Sqmm Aluminium armoured conductor
3.5CX 25 Sqmm Aluminium armoured conductor
3.5CX 120 Sqmm Aluminium armoured conductor
Supplying & laying of 2x1.5 sqmm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm)
3.5 CX 25 Sqmm Al Arm LT Cable End Joint
3.5 CX120 Sqmm Al Arm LT Cable End Joint
Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply, fixing & connecting the 50X6mm size G.I strip on wall / clamping to the existing duct wall / fixing on steel structures/ laying 2 ft. below the ground level with necessary excavation, concrete cutting & re-concreting, refilling, consolidation & levelling of soil after laying for interconnection between the earth pits and the LT & HT panels earthing & Transformer body earthing as directed by Engineer-in-charge. Note:- Excavation, concrete cutting & re concreting will be measured separately.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Excavation in all types of soil for Cable trench including refilling, consolidating of soil after laying the cable including ramming and levelling to smooth finish as per the Technical specifications enclosed and as directed by the Engineer-in-charge.
Demolishing Cement Concrete manually/machanical means including disposal of material within 50 metres lead as per direction of Engineer in charge
Nominal Concrete 1:C422: or richer mix (including equivalent design mix)
Re-concreting the cut portion/closing the dummy cable duct at same area with 1:2:4 cement concrete by employing 20mm graded aggregate granite to smooth finish including curing and form work if any complete in all respects and as directed.
Design, fabrication, Supply, erection, testing & commissioning of Indoor type Automatic transfer switch LT PANEL (PTTA)
Incoming
2-nos 125A 415V gr 4P 36KA MCCB with thermomagnetic release
Lot - 200A, 4P, 415V, short circuit rated 25KA for 1sec, Aluminium bus bars with busbar insulators, heat shrinkable PVC sleeves etc.
2Nos- Multi function meter (MFM/MDM) suitable for 3ph, 4 wire, 240V(L-N), 5A, CL-1, RS 485 Port Digital MFM/MDM of EM6400NG of Schneider or any equivalent make meeting technical specification of above MFM complete in all respect.
2 Set-125/5A current transformers of suitable class and VA burden for metering.
2Set - RYB indicating lamps of LED module with 6A, 230V, 10KA, SP MCB.
2Set- 6A, 230V, 10KA, SP MCB for the protection of measuring instruments.
01 set- Automatic transfer switch unit suitable for load up to 125A Model no-CK90161BSOO of Lauritz Knudsen or any equivalent make meeting technical specification of ATS complete in all respect.
Outgoing
6-No 63A 415V gr. 4P 25KA MCCB with thermomagnetic release
6-Nos 32A-40A 415V gr. 4P 25kA MCCB with thermomagnetic release
LIFT PANEL DB
4way VTPN MCCB DB.
63 amps. ratings , 4P RCBO, "C" curve, 10 KA breaking capacity.
5A to 32A TP MCB 10kA , C Curve
Supply, installation, testing and commissioning of 1row 12modules weather proof DB/cabinet mounted at suitable height on the wall using suitable size MS angle frame work with painting as per EIC, with cable entry knock-outs, including rigid support for all components, Din channel, required fasteners, necessary interconnections, dummy plates, totally enclosed, dust and vermin proof and degree of protection shall not be less than IP-65 complete in all respects and as directed by Engineer-in-charge. The DB/Cabinet may be of Hensel make of model no KV9112M or equivalent in Legrand/ Schneider/ Hagar make only. Note: MS supports will be paid separately.
Rupees Seventeen Lakh Thirty Thousand Four Hundred Ninety Three and Twenty Six Paise Only
Two Loop Panel.
Supplying,installation,testing & commissioning of intelligent adressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required as per CPWD specification.
Supplying,installation,testing & commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required CPWD specification.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required as per CPWD specification.
Supply, installation, integrating with the existing main FACP, testing & Commissioning of Auto dialer with addressable control module connected to main control panel with minimum 10 telephone nos. connectivity working on 24volts supply including connected cabling/wiring complete in all respects, as per technical specification.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying & laying of 2x1.5 sqmm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Rupees Five Lakh Four Thousand Three Hundred and Nineteen Paise Only
OUTDOOR UNIT Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load.The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39°C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building) For Cooling or Heating or Both
INDOOR UNIT Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor)
Design, Supply, installation, testing and commissioning of suitable size hard/soft refrigerant copper pipe as required with required pipe fittings , accesories, filter drier and couplings by good quality pipe joints which laid between ODU and IDU The Minimum copper pipe gauge shall be as per the gauges indicated by manufacturer. The Pipe sizes to be used as per OEM design recommendation. The Refrigerant pipe shall be insulated with Class O nitirle rubber of 19 mm thick for Gas line and 19 mm thick for liquid line. The piping shall be laid on walls / roof / ceiling well supported at specific intervals with metallic support, Cable tray with cover and required hardwares etc., for fixing copper pipes. All the necessary accessories, jointing / brazing etc shall be carried out as required. The pressure testing of refrigerant piping has to be done as per manufacturer design recommendation. All the copper fittings shall be suitable for R 410 A/R 407R 134a//R-32 refrigerant. . Make: Mandev/Piyush/Totaline (Note: 1. Irrespective of diameter both gas and liquid piping shall be measured as a single item. The single item measurement comprising of gas line, liquid line, insulation and its accessories. Contractor make a note of it and quote accordingly. 2. Before commencement of work, shop drawing to be submitted to OIC/EIC for approval. )
Design, supply, Installation testing & commissioning of suitable sizes as per OEM recommonadation not less than 2mm thick CPVC drain water, reducer, bends, collars & elbow etc, all complete and duly insulated with 9 mm thick tubular insulation of closed cell elastomeric nitrile rubber as required.The PVC drain water pipe shall be complete with fittings, accessories and duly insulated using bends, elbows, tees, wall sleeves, hangers, supports, anchors etc.(Note: Necessary wall openings and closing the same using cement mortar and matching paint finish after taking out pipes is included in the scope of work. )
Supplying & laying of 2x1.5 sqmm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Rupees Three Lakh Nineteen Thousand Fifty Three and Thirty Paise Only
Rupees Twenty Five Lakh Fifty Three Thousand Eight Hundred Forty Six and Seventy Five Paise Only
Rupees One Crore Eleven Lakh Forty Nine Thousand Nine Hundred Eighty Seven and Thirty One Paise Only
Approximate Amount Put to Tender
Rupees Twenty Lakh Six Thousand Nine Hundred Ninety Seven and Seventy One Paise Only
Rupees One Crore Thirty One Lakh Fifty Six Thousand Nine Hundred Eighty Five and Three Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.05 MB
TN61.pdf
pdf • 0.60 MB
60TBF.pdf
pdf • 5.27 MB
60PQF.pdf
pdf • 0.20 MB
60PBF.pdf
pdf • 0.71 MB
Civil_Drawing.pdf
pdf • 0.59 MB
ACtenderdrawings.pdf
pdf • 0.31 MB
Electricaltenderdrawings.pdf
pdf • 1.46 MB
60ECSForm.pdf
pdf • 0.48 MB
60UNDERTAKING.pdf
pdf • 0.57 MB
60CHECKLIST.pdf
pdf • 0.19 MB
60PQ.xlsm
xlsm • 0.03 MB
60PB.xlsm
xlsm • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .