Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC AT PO JARIDIH BAZAR P S GANDHI NAGAR BOKARO JHARKHAND 829114 | JARIDIH BAZAR | BOKARO | JHARKHAND | 829114 | L1 | Accepted-AOC TECHNO COMMERCIALLY SUITABLE BID | |
| 2 | Rejected-Technical | - | Rejected-Technical NOT L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT L1 |
Tender Value
₹3.0 L
EMD Value
₹3,800
Closing Date
17 Oct 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GENERAL MANAGER,NEC,MARGHERITA
OFFICE OF THE GENERAL MANAGER,NEC,MARGHERITA
ELECTRICAL REPAIRING OF BUNGLOWS AND DEHING TRAINING INSTITUTE OF MARGHERITA AREA, NEC, CIL
2023_NEC_290524_1
RWS/T/E.39/2023-2024/20
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
NEC, MARGHERITA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,800
22 Mar 2024
7 Oct 2023
18 Oct 2023
7 Oct 2023
17 Oct 2023
7 Oct 2023
7 Oct 2023 - 10 Oct 2023
Amount
Wiring for drawing sub-main line with 2 x 1.5 sq mm. PVC insulated single core unsheathed industrial(Multistrand) cable FR confirming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kabel or its equivalent make as approved by the deptt) in surface flat 19 mm.ISI marked casing & caping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by deptt.) system,including connection as required.
a) With 2 x 1.5 sq mm. cable in surface flat 19 mm ISI marked casing & capping system.
Wiring for drawing sub-main with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex/RR Kabel or its equivalent make as apporved by the deptt) in surface flat 19 mm ISI marked casing & capping ( AKG/Precision/Presto Plast/Polycab/MW or equivalent ame as approved by the Deptt.) system including connection as required.
a) With 2x 2.5 sq mm + earth continuity with 1x 1.5 sq mm. in surface falt 19 mm casing & capping system
Wiring to 5 pin 6 Amps plug point with 1.5 sq mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade upto 1100 Volts (Finolex/RR Kabel or its equivalent make as apporved by the deptt) including providing and fixing 5 pin 6 Amps socket outlet (Anchor penta/Gold Medal/Kolor Keny. Kom/Havells or equivalent make as approved by the deptt.) and 6 Amps flush type switch (Anchor penta/Gold Medal/Kolor Keny.Kom/Havells or equivalent make as approved by the Deptt.) earthing the 3rd pin in the socket as required on the switch board in surface flat ISI Marked casing & capping system when fitted on same board of light and fan
Wiring for light/fan/call bell point with 2 x 1.5 sq mm PVC insulated single core unsheathed industrial (Multistrand) cable FR confirming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 Volts (Finolex/RR Kabel or its equivalent make as approved by the deptt.) in surface flat 19 mm ISI marked casing and capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system complete
a) Short Point upto 3.00 mtr Length
b) Medium Point upto 6.00 Mtr Length
c) Long Point upto 10.00 Mtr Length
Wiring to 5 pin 6 Amps plug point with 1.5 sq mm PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade upto 1100 Volts (Finolex/RR Kabel or its equivalent make as apporved by the deptt) including providing and fixing 5 pin 6 Amps socket outlet (Anchor penta/Gold Medal/Kolor Keny. Kom/Havells or equivalent make as approved by the deptt.) and 6 Amps flush type switch (Anchor penta/Gold Medal/Kolor Keny.Kom/Havells or equivalent make as approved by the Deptt.) earthing the 3rd pin in the socket as required on the switch board in surface flat ISI Marked casing & capping system
b) Medium Point upto 6.00 Mtr Length
Supplying with fitting and fixing single pole 10 KA 240/415 V 50 Hz MCB of the following capacity completed with making necessary connection as approved,specified and directed by the Deptt.
a) C Series 6 Amps
b) C Series 10 Amps
Supplying with fitting and fixing DP 10 KA 240/415V 50 Hz MCB of the following capacity complete with making necessary connection as apporved, specfied and directed by the Deptt.
a) C Series 6 to 32A
Supplying , Fitting and fixing of ceilling fan regulator including connections etc. complete as required (Electronic Type)
Total impact of GST for the purpose of CTC
Technoelect
M/S A. G. ELECTRICAL
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_300912.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .