Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Documents are found in order |
| 2 | Accepted-Technical | Accepted-Technical Documents are found in order |
| 3 | Accepted-Technical | Accepted-Technical Documents are found in order |
Tender Value
₹86,805
EMD Value
₹1,736
Closing Date
26 Feb 2026, 12:00 pmClosed
Assistant Engineer (Elect)
3rd floor E Block Pushpa Bhawan Madangir New Delhi 110062
Improvement and Upgradation of Room No. 133 in Block No. 04 CGO Complex under FHQ BSF New Delhi Sub Head Electrification
2026_BSF_899448_1
19/NIT/ENGG/ELECT/2025-26
Open Tender
Electrical Works
Percentage
15 days
FHQ BSF Block No. 10 CGO Complex Lodhi Road New De
As per NIT
9 documents required · 9 mandatory
₹0
₹1,736
3 Mar 2026
19 Feb 2026
27 Feb 2026
19 Feb 2026
26 Feb 2026
19 Feb 2026
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Group C)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group B)
Wiring for circuit/ submain wiring alongwith earth wire the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recess medium class PVC conduit as required. (3.1) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of 25 mm size of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. (5.1) 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Bell push
Blanking plate
32 A DP one way switch
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. Make Anchor Roma/Great White/Legrand (6.1) 1 or 2 Module (75 mm x 75 mm)
3 Module (100 mm x 75 mm)
6 Module (200 mm x 75 mm)
Supplying and fixing 3 pin 5 amps ceiling rose on the existing junction box/ wooden block including connection etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing call bell buzzer suitable for single phase, 230 Volt, complete as required.
Supplying and fixing extra conduit down road 20 cm length G.I. pipe 15 mm dia, heavy guage including painting etc. as required. (Note more than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing 12 way, double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Make Havells/Simens/Legrand/ L&T/ABB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make Havells/Simens/Legrand/ L&T/ABB
Supplying and fixing 40 Amp rating, 240 V, double pole, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make Havells/Standard/C&S/ L&T/ABB
Supplying and fixing 8 module GI box with modular plate and cover in front on surface on recess, including providing and fixing 1 Nos. 6 pin 15/16 Amp modular socket outlet, 2 Nos. 3/5 pin 5/6 Amp modular socket outlet and 2 Nos. 15/16 Amp one way modular switches connections etc. complete as required. For power plug to be used in non residential buildings Indoasian make or its equivalent to Anchor/Legrand/White great make
Supplying, installation, testing and commissioning of 1200 mm sweep ceiling fan including nut, bolts etc. complete as required. Model Winzer Crompton make or equivalent to Havells/Bajaj/USHA make
Supplying, installation of 250 mm fresh air/ ventilating fan plastic body with louvers/ shutters complete with frame in the existing opening, including making good the damage, connection, testing etc. as required. Model Brisk Air Neo Crompton make or equivalent to Bajaj/Havells/USHA make
Providing and fixing of 2' x 2' feet size, 36 watt, 3000 K/ 6500 K, LED slim light panel of square shape along with electronic driver suitable for recess type grid ceiling mounting as per direction of engineer-in-charge including connection, testing etc. complete as required. Model No. Octane Plus LED 2X2 Panel, Cat. No. LHEBAEP5IW1W036/ LHEBAEP7IW1W036 Havells make or equivalent to Bajaj/Crompton/Philips/Wipro
Add GST factor 1.0633 on DSR item Sr. No. 01 to 13 i.e. on Rs. 55836.00
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.79 MB
BOQ_945410.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .