| Sl No | Description | Qty | Unit | M S Enterprises L1 | Vivek Electricals L2 |
|---|---|---|---|---|---|
| 0.00fctusl Iyku 24&25 ¼ikVZ&2½ ;kstuk ds vUrxZr fo|qr forj.k [k.M&[kqtkZ ds dk;Z{ks= esa 33@11 dsoh fo|qr midsUnzks ds vUrxZr forj.k ifjorZdksa ds izksVsD'ku laca/kh dk;Z] ,p0Vh0 ykbZu fuekZ.k] ykbZuksa dk lqn`<hdj.k dk dk;Z] oh0lh0ch0 lacaf/kr dk;Z ,oa vU; dk;ZA | |||||
| 1.00Carriage of fallowings from esc. Bsr to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 kms. | |||||
| 2.00 | 11 mtr STP Pole long. | 6 | No. | 1,000 ₹6,000 Lowest | 1,010 ₹6,060 |
| 3.00 | 11 mtr pcc pole | 18 | No. | 1,500 ₹27,000 | 1,450 ₹26,100 Lowest |
| 4.00 | 11 kv vcb incomining/outgoing complet | 7 | No. | 5,000 ₹35,000 | 4,999 ₹34,993 Lowest |
| 5.00 | Bus isolator 800 a 33 kv | 2 | No. | 2,500 ₹5,000 | 2,490 ₹4,980 Lowest |
| 6.00 | Line isolator 800 a 33 kv | 2 | No. | 2,500 ₹5,000 | 2,490 ₹4,980 Lowest |
| 7.00 | Carriage of all line material from store center bsr to j.e store sub station as acsr weasel conductor, abc conductor gi wire, earth wire. M.s. Chanel, angle, stay & earthig rods, barbed wire. Disc insulator etc. | 10 | Qtl. | 400 ₹4,000 Lowest | 500 ₹5,000 |
| 8.00Erection of single pole support including complete 1 it fittings as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. Required for proper completion of work. | |||||
| 9.00 | 11 mtr STP Pole long. | 4 | no | 2,000 ₹8,000 Lowest | 2,000 ₹8,000 Lowest |
Tender Value
₹9.6 L
EMD Value
₹9,600
Closing Date
15 Sept 2025, 1:00 pmClosed
SE EDC-I BSR
SE EDC-I HYDEL COLONY BULANDSHAHR
Business Plan 24-25 (Part-2) Under the scheme, work related to protection of distribution transformers, construction of HT line, work of strengthening of lines, VCB related work and other works.
2025_PVVNL_1039189_1
T-98/EDC-I/B/2024-25
Open Tender
Electrical Works
Item Rate
30 days
BULANDSHAHR
PLZ REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹1,180
SE EDC-I
₹9,600
18 Sept 2025
15 May 2025
15 Sept 2025
15 May 2025
15 Sept 2025
15 May 2025
Amount
fctusl Iyku 24&25 ¼ikVZ&2½ ;kstuk ds vUrxZr fo|qr forj.k [k.M&[kqtkZ ds dk;Z{ks= esa 33@11 dsoh fo|qr midsUnzks ds vUrxZr forj.k ifjorZdksa ds izksVsD'ku laca/kh dk;Z] ,p0Vh0 ykbZu fuekZ.k] ykbZuksa dk lqn`<hdj.k dk dk;Z] oh0lh0ch0 lacaf/kr dk;Z ,oa vU; dk;ZA
Carriage of fallowings from esc. Bsr to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 kms.
11 mtr STP Pole long.
11 mtr pcc pole
11 kv vcb incomining/outgoing complet
Bus isolator 800 a 33 kv
Line isolator 800 a 33 kv
Carriage of all line material from store center bsr to j.e store sub station as acsr weasel conductor, abc conductor gi wire, earth wire. M.s. Chanel, angle, stay & earthig rods, barbed wire. Disc insulator etc.
Erection of single pole support including complete 1 it fittings as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. Required for proper completion of work.
11 mtr STP Pole long.
11 mtr pcc pole
Erection of double pole/scation pole support including complete 1 it fittings as per respo manual and as per direction of engineer in charge including the cost of labour, t&p and carrier etc. Required for proper completion of work.
11 mtr STP Pole long.
11 mtr pcc pole
Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
11 mtr STP Pole long.
11 mtr pcc pole
Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
11 mtr STP Pole long.
11 mtr pcc pole
Proveding & Fixing/Inss
Fixing of 11 KV VCB Incomining/Outgoing complet
Stay Set Completed
Proveding & Fixing of Static Relay
Fixing of ACSR Dog Conductor.
Fixing of Cable Jointing Kit O/D & I/O
Fixing of Batteri set
Fixing of Batteri charger
Provading of Batteri MS stand
Proveding & Fixing of Batteri MS stand
Providing 4x2.5 mm² of Control Cable
Fixing of 4x2.5 mm² Control Cable
Fixing of Bus ISOLATOR 800 A 33 KV
Fixing Line ISOLATOR 800 A 33 KV
Proveding & Fixing Danger Bord
Proveding & Fixing F Clamps
Proveding & Fixing Holding Clamps
Fixing Earthing Rod
Fixing of 11 Kv stay set
Grouting of 11 Kv stay set
Fixing of 11 KV pin Insulator
Fixing of 11 KV Disc Insulator
Fixing 11 KV Vtype X arm.
Providing, fabricating carrying & fixing of Henley type Tailless double circuit Fuse Unit hook type arrangement having 3 Phase + Neutral arrangement in each leg ( 2 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 500AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 500 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 250 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor.
Fabrication and fixing MS Droper/Toper Channel
Provideing & Fixing OTI/WTI
Provideing & Fixing Wire
Provading of Nut-Bolts off size
Fixing of Nut-Bolts off size
Vivek Electricals (BID ID -5535331)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .