Supply, installation, testing and commissioning of electro-mechanical equipment at water supply scheme Dachnimall (Stage 1st and Stage 2nd) of Jal Shakti (PHE) Mechanical Division South Awantipora under JJM.
2025_PHE_296788_1
JSD/PHE/MDSA/ e-NIT No. 36
Open Tender
Machineries/ Mechanical Engg Items
Percentage
75 days
Dachnimall
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Executive Engineer PHE Mech. Div. South Awantipora
₹2.2 L
28 Jul 2026
29 Nov 2025
25 Jul 2026
29 Nov 2025
24 Jul 2026
29 Nov 2025
Supply, Installation, Testing & Commissioning of Submersible Pumping Unit V 6 as per IS 8034 with latest amendments having the specification as under:- PUMP: =Suitable for well casing Discharge = 2500 GPH assumed Head = 330 m Efficiency = Not less than 50% Speed = 2900 Rpm Type of pump : Mixed flow. Type of fluid to be handled = Ground water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel / Bronze/ chrome steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve: Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method of starting = Star – Delta Speed = 2900 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 380 -415 ± 15% V, 03 phase Efficiency =As per IS 9283 (2013) with latest amendments. Rating = Not less than 25 HP Class of insulation
= F/ B Submersible motor should be water filled, water lubricated squirrel cage type ,working on 3 phase; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length. b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of thickness (as per Table-17) at other end for 65 mm diameter column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing. The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site. Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory.
Supply, Installation, Testing And Commissioning of earthing station for D.G SET comprising of company fabricated GI earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip (25x3mm) as per relevant standards. Safe earthing electrode size : 80 mm dia , Length : 2000 mm Back fill compound : 30 kg
Supply, Installation, Testing & Commissioning of Submersible Pumping Unit V 6 as per IS 8034 with latest amendments having the specification as under:- PUMP: =Suitable for well casing Discharge = 2200 GPH assumed Head = 470 m Efficiency = Not less than 50% Speed = 2900 Rpm Type of pump : Mixed flow. Type of fluid to be handled = Ground water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel / Bronze/ chrome steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve: Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method of starting = Star – Delta Speed = 2900 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 380 -415 ± 15% V, 03 phase Efficiency =As per IS 9283 (2013) with latest amendments. Rating = Not less than 30 HP Class of insulation = F/ B Submersible motor should be water filled, water lubricated squirrel cage type ,working on 3 phase; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length. b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of thickness (as per Table-17) at other end for 65 mm diameter column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing. The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site. Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory. Suggested Make: CRI
Providing/supplying and fitting of G.I flanged Rising Main– The Pipe shall be hot dip Galvanized, class C class Heavy pipe confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:13
Filling available excavated earth in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift upto 1.5m.
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil- 1m from cutting edge.
Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns.
63 Part 1st) Rubber Insertion Gaskets Rubber Insertion Gaskets (conforming to IS: 638/79) to be used between flanged joints. The main technical specifications of the pipe are given here under: Size: DN 65mm Class "C" Heavy Note: Steep head load accounted for the execution of the job. Test/inspection certificates from the Manufacturer must be produced on delivery of the item.
Fabrication, providing and fitting of split type MS clamps 10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size : 65 mm
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1 : 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size). blocks for rising main.
Fabrication, Providing and fitting of 90-120 degree bend/elbow to be fabricated out of Class C GI pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with welded jointson three ends. The job includes nuts, bolts, gaskets etc complete. Size : DN 65, Class C
Fabrication, providing and fitting of washout Tee. The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. The size of the Tee is given Below: ND= 65 MM Class: C
Supply, Installation, Testing and Commissioning of Ductile Iron double flanged, non-rising spindle Resilient seated gate/ sluice valves (PN16) in accordance with BS 5163 part 1 and part 2 / EN 1074 Part 1 & 2/ IS 14846 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. The Test Certificates of Sluice/Gate Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material. Size: DN 65 mm Rating: PN 16
Supply, Installation, Testing and Commissioning of Ductile Iron double flanged, Slanted seat swing check valve (NRV) (PN16) as per EN 1074- Part -3 / BS 5153/IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 Nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. The Test Certificates of Check Valves (NRVs) mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material Size: DN 65 mm Rating: PN 16
Providing and fitting of 02 core, XLPE, 1.1 KV and 11 KV grade Armoured Aluminum Cable of Various sizes confirming to IS:7089 part 1st as service line from HT transformer to Control panel including necessary thimbles, crimping, taping etc. Size: 10 sq mm Note: Steep head load accounted for the execution of the job.
Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: - i. Valve type - single chamber, single/double orifice. ii. End connection - flanged ends to IS 1538 iii.Working temperature - 45oc to -150 c iv. Test pressure - body / seat 2.5 x PN v. Sealing ring - EPDM vi. Construction -ductile iron with stainless steel floats vii. Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, GI Pipe, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. The Test Certificates of Air Release Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material. Size : DN 50 Rating: PN16
Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns.
Providing and laying of stone soling including manual compaction.
Fabrication of gantry mechanism by way of providing Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded.
Earth work in excavation required for installation of gantry by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil- 1m from cutting edge.
Supply, Installation, Testing and Commissioning of outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer (Level-2) Capacity:- 63 KVA Type of cooling: ONAN. Operating conditions: Input =11000 volts Output = 433 volts AC supply in 3- phase. Terminals: Input=3 No. HT Brass bush rods with insulators, washer, nuts etc. Output=4 No. LT Brass bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vent and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size).
Painting of the gantry and plate form of well using one coat of red oxide metal primer and two coats of enamel paint of different shades.
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type.
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creepage distance 320 mm.
Providing and fitting G.I Channel /Angle/ Flat/ V crosses/ F- tops of sizes including clamps. The job includes fitting of Channels on two poles for the installation of insulators and safety devices, GO Set, Lighting Arrestor etc. It also includes the channels for fitting of LT Meter and LT Distribution Box. The job includes P/F of GI channels at Tapping point for installation of GO Link Set, Pin Insulators Etc as per site requirement. Size of Channel= ISMC 75X40MM & ISMC 100x50mm
P/F of Galvanized nuts bolts of various sizes as per site requirement.
Supply, Installation, Testing and commissioning of 01 No. Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT pole double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings, operating handle and 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. The 11 KV AB switches shall conform to IS: 9920 (Part-I to IV). 01 No. GO Set is to be fitted at tapping point and 01 No at HT Transformer (Substation). Testing/Inspection Certificate as per IS 9921 Part IV is mandatory and is to be produced at the time of supply of material
Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns.
Providing and laying of stone soling including manual compaction.
Fabrication of gantry mechanism by way of providing Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded.
Supply, installation, erection of 9 mtrs long H.T pole of specifications ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories, wherever required the job further includes G.I wire earthi
ng of pole as per IEC standard.
P/F Danger Plate with clamps on every HT pole.
Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices. The barbed wire shall be tightly close wrapped around the pole for 10-12 turns, commencing at 2.50m above the datum line.
Providing and Fitting of PG Clamps.
Supply, Installation, Testing and Commissioning of Galvanized stay set with 50 X 8 mm Stay Clamp, Guy insulator (2 No.), Anchor plate (200X200X6mm), nuts and bolts, 2 No.- turn buckle, 1.8 m long, 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.
Earth work in excavation required for installation of HT poles by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil- 1m from cutting edge.
Painting of poles with red oxide.
Supply, Installation, Testing and Commissioning 11 KV cable termination kit for connecting 35 Sq mm ABC cable (ABC type) with the existing HT line near tapping point and HT transformer.
Painting of poles with Aluminum Paint.
Supply, installation, testing of 35 sq mm XLPE HT cable (ABC type) of 11 KV Grade with following specifications size cross sectional area in sq mm )=3x35 phases Red, Yellow, Blue
Supply, Installation, Testing and Commissioning of PRODIGY LT Meter of following specification complete with all fixtures required for fitment at site Type: 3 Phase, 4 wire Measurements offered: KWh, KVARh, KVAh, KVA Voltage : 3x240V (415v), 50HZ Ib : 40A Imax: 200A Battery: Lithium The Prodigy Meter must be fitted inside the Box, that is to be fitted on GI Channels near LT Distribution Box. Both the enclosures must be symmetrical Sealing /Inspection report of Prodigy meter from JKPDCL (Concerned) is to be submitted by the firm at the time of charging of SUBSTATION.
Providing and fitting of anchoring clamps comprising clamp body, plastic wedge, steel bill bracket, straps and buckles or nuts and bolts required for holding three core, 35 sq mm HT AB cable.
Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 0.50 sq.mm ACSR (Galvanized steel reinforced) for fitment of various accessories.
Supply, Installation, Testing and Commissioning of LT Distribution box for H.T transformer with 200A MCCB for incomer and 100A SFU for outgoing circuits. The LT distribution Box is to be fitted on GI Channels. Capacity of transformer: 63kVA
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below: Size :- 16 sqmm
Supply, Installation, Testing and Commissioning of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated GI earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip (25x3mm) as per relevant standards. Safe earthing electrode size : 80 mm dia, Length : 2000 mm Back fill compound : 30 kg
Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structures at the top having 120˚ angle between arms and each arm having 15˚ inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code.
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole. Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120˚ - 170˚ Lumens: >12000 Operating Temperature: -20˚C to 60˚C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is properly fitted on the arm of the pole and connected to the copper wire as provided in the high mast pole.
Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection (For Well) Class : IP-55 & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER( Rating 160 Ampere). All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards b) Main Circuit Breaker (Incomer MCCB): Qty. = 02 No. No. of poles = 4 Pole Current Rating =200 Amp. Rated operational voltage = 415 V + 15 % Rated frequency = 50+/-3%Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) =50 KA, Type of release = Thermal-Magnetic Overload protection = 0.8 – 1×ln adjustable Short-circuit protection = 6-10×ln adjustable. c) Change over Switch: Qty. = 01 No. Rating =100 Amp, Type = Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz d) Motor Back-up Protection MCCB: Qnty = 2 No. No.of poles = 3Pole, Current Rating = 125 Amp, Rated operational voltage = 415 V +15 % Rated frequency = 50 + 3% Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36KA. e)Submersible starters:-= Fully automatic star delta. Capacity = Mug 50, Power Specs = 3 Ф, 415 + 15% V, 50 + 3 % Hz. Relay range = 45-75Amp, Coil Voltage = 380 v Protection = single phasing, phase Reversal, phase unbalance (55 ± 5 V), Rated insulation voltage = 690V Terminal capacity = 120 Sq. mm with lug Or above Conformity to standard = IS/IES 60947-4-1 Qty. = 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty. = 1 No. No. of poles = 4P, Current Rating = 63Amp. Rated operational voltage = 415 V + 15 % Ultimate S.C Breaking Cap. at (240V AC, 50 Hz) = 25 KA g) Motor Protection Relay: Digital Motor Protection Relay with LCD Display for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, over current, Prolong starting, Locked Rotor, Under voltage, over voltage & Earth fault. 02 No,s 01 for each starter h. M-power module for mobile starter for submersible motor 1P/3P 3 wire IVRS Languages – English , Hindi, Suitable Region- North India 02 No,s 01 for each starter. The panel shall be provided with phase indicators (03 N0,s) and digital ammeter of range 0-60 A, digital voltmeter of range 0-500 V, and digital frequency meter 01 No for each starter(Single Function Type). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and powder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements / angle iron or channel supports MUG 50 i) Bus bar size 160A ii) D-sine MCCB 4 pole (DN2 250N, 125-160A, 50kA) iii) Change over switch Front Ope
rated 200A iv) D sine MCCB 3 pole (DZ1-160D ,84-125A, 36kA) v) Mug x 2 (Mug 50, 45-75Amp relay) vi) Auxiliary MCCB 63Amp vii) MM 10 of L&T (Motor Protection) Motor Protection viii) Module for mobile starter ix) Meters , (Ammeter & voltmeter) 2 No. each and Freq Meter x) Indicators LS xi) Over load and Under Voltage Minlec
Supply, Installation, Testing and Commissioning of 2KVA fully automatic voltage stabilizer with input voltage 70-240 V and output 220 V. The stabilizer shall be installed and connected to the electric circuit as per location provided by site in charge. The voltage stabilizer is to be connected to the heating and lighting circuit of the scheme including the street lights.
Supply, installation, Testing & commissioning of 1050VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Tubular inverter Battery with trolley and cover. with 2-core 4 mm2 Cu (25 m) wiring as per site requirement along with other accessories like SS-Combine (02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.
Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: - Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate.
Supply, Installation, Testing And Commissioning of, 3.5-Core, XLPE, 1.1KV and 11KV grade Armoured Aluminium Cable conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. (Service line from HT Transformer and D.G Set). i) 50 sqmm, 3.5 core, LT cable
Supply, Installation, Testing and Commissioning of L.T, 1 core, capable to work up to 1.1 KV, XLPE insulated, galvanized steel strip armoured copper cable conforming to IS : 7098(part -1) 1988 With latest amendments to be fitted from modular control panel to stabilizer etc. (interconnecting cable). The job includes providing and fitting of suitable rating copper thimbles duly crimped and taped at conductor ends by hydraulic crimping tool. The job includes earth work in excavation wherever required for laying of cable underground. Size: 16 sq mm
Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6'x3' (6Kg)- 02 No’s. ii) Quilt with warm cover size 5'x8' (6Kg)- 02 No’s. iii) Pillows with covers - 02 No’s. iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton b) The job also includes providing of pressure cooker 5ltr 02 No’s, Steel patella(utensil) 5ltrs 02 No’s, cooking heater 01 No., room heater 01 No., steel buckets 10 litre capacity 01 No., Plastic bucket 10 litre capacity with Mug 02 No’s each, steel glasses 06 No’s, steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo-cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of Godrej, Link locks.
Providing and fitting of 02 core, XLPE, 1.1 KV and 11 KV grade Armoured Aluminum Cable of Various sizes confirming to IS:7089 part 1st as service line from HT transformer to Control panel including necessary thimbles, crimping, taping etc. Size: 10 sq mm
Supply, installation, testing and commissioning of 58.5 kVA, 3 Phase, 415V AC, Silent DG Set confirming to CPCB IV + comprising of Engine, with minimum 74.4 BHP, at 1500 RPM, coupled with alternator and mounted on a common base frame complete with • Fuel tank • Battery & leads • Silencer – Residential • AVM(Anti-Vibration Mounting) pads • Standard control panel • First Fill of lube oil • Acoustic enclosure • Aluminium Power cable ( upto 60 mtr) •Transportation upto Site •Commissioning The DG set shall be able to operate at 1850m ASL TECHNICAL REQUIREMENT DIESEL ENGINE Type : The Diesel Engine shall be suitable for generating set application • Developing specified BHP at 1500 RPM under NTP conditions of BS: 5514 or equivalent in IS, Liquid cooled, Turbocharged Inter-cooled, powered by four (4) strokes, multi cylinder with engine performance requirement as specified below. Diesel engines shall be as per MOEF (MINISTRY OF ENVIRONMENT, FOREST AND CLIMATE CHANGE) notification dtd. 3rd November 2022. Only Indian origin Engine is acceptable as per PPP (Public Procurements P-45021/2/2017-PP(BEII)) policy Nominal Output : To match with, alternator 58.5 kVA at 0.8 pf (lagging) i.e., 46.8 kW. • Revolution : 1500 rpm • Starting System: 12 V battery operated electric motor starting. • Fuel : High speed diesel oil • Governing Class: G3/G2 • Aspiration System : Turbocharged Inter-co
Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole. Having following specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120˚ - 170˚ Lumens: >12000 Operating Temperature: -20˚C to 60˚C The LED is pressure die cast aluminum housing with power coated finish and having Ingress Protection up to IP-68. The LED is properly fitted on the arm of the pole and connected to the copper wire as provided in the high mast pole. Note: Steep head load accounted for the execution of the job.
● Rated frequency : 50 Hz ● Overload capacity : 10% for 1 hour ● Over speed withstand capacity : 110% of rated speed for 1 min ● Voltage Regulation : Within +/- 1% of rated voltage from no load to Full load ● Frequency Regulation : Within +/- 4% from no load to full load TESTS AT SITE The job includes providing of Diesel 100 Litres for testing on load. PACKING ● The materials shall be property packed before dispatch to avoid damage during transport, storage and handling. ● Proper arrangement shall be provided to handle the equipment. INSTALLATION, ERECTION, TESTING AND COMMISSIONING The job includes providing and laying in position cement concrete foundation of 4m*3m*1m of specified grade all work up to plinth level with 1: 2 : 4 mix ( 1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size) along with required soling stone and centering and shuttering. ● The generator set, control panel, as well as the neutral of the generator shall be effectively earthed. ●XLPE (L.T 3.5 Core) power cabling is to be provied by the contractor (as per requirement). Necessary aluminum power fittings, cable glands, cable end lugs, PVC numbering ferrules, tapes etc. shall be supplied and installed by the contractor. ● Residential Silencer and The exhaust pipe upto Silencer shall be provided with each DG Set ● The Supplier shall follow occupational health and safety norms,
Supply, Installation, Testing & Commissioning of Submersible Pumping Unit V 6 as per IS 8034 with latest amendments having the specification as under:- PUMP: =Suitable for well casing Discharge = 2200 GPH assumed Head = 470 m Efficiency = Not less than 50% Speed = 2900 Rpm Type of pump : Mixed flow. Type of fluid to be handled = Ground water MATERIAL OF CONSTRUCTION: Impeller = Stainless Steel / Bronze/ chrome steel Pump Shaft = Stainless Steel SS 410. Pump Casing = Cast Iron/Stainless steel IMPELLER: Impeller is of the enclosed or semi – enclosed type and properly balanced. Enclosed Impellers equipped with seal rings on their hubs. COUPLING: A suitable coupling arrangement provided with pump set. Non Return Valve: Non Return Valve of the suitable size provided above the pump discharge case. MOTOR:- Method of starting = Star – Delta Speed = 2900 (Sync). Frequency = 50 ± 3 % Hz Working Voltage = 380 -415 ± 15% V, 03 phase Efficiency =As per IS 9283 (2013) with latest amendments. Rating = Not less than 30 HP Class of insulation = F/ B Submersible motor should be water filled, water lubricated squirrel cage type ,working on 3 phase; AC supply ranging from 380 to 415 volts, 50Hz. The motor should be sealed by radial rings to avoid mixing of well water with motor a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length. b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of thickness (as per Table-17) at other end for 65 mm diameter column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing. The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the well then proper testing and commissioning of pumping unit on full load at site. Note: Providing of test certificate & Characteristic Curve of pumping equipment is compulsory. Suggested Make: CRI
Providing/supplying and fitting of G.I flanged Rising Main– The Pipe shall be hot dip Galvanized, class C class Heavy pipe confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16). The flanges shall be double welded both from inside and outside of the pipe using standard electrode of reputed make. Flanges (as per IS 6392/1997 Table:17) Thickness shall conform to IS 6392 Part 1st Table-17. The flange welding shall be carried out in double layers using reputed make electrodes to form strong welding joint. Welding Electrode DC Arc Welding using welding electrode having diameter not less than 4mm. Nuts and Bolts Nuts and Bolts (conforming to IS:13
Filling available excavated earth in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by reaming and watering, lead upto 50 m and lift upto 1.5m.
TOOL KIT For Maintenance: - The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of Providing of tool kit consists of following items: i. Double ended Spanner (Chrome plated) 01 set complete (6-32) sizes ii. Double ended Ring spanners chrome plated 01 set complete (6-32) sizes iii. Cutting plier 9 inch -------1 No. iv. Long nose plier; size in mm 205 – 01 No. v. Insulated screw Drivers 12 inch, 9 inch, 6 inch---------------01 No. each vi. Hammer 1 kg--------------------01 No. vii. Heavy duty pipe wrench 24 inch -----------------– 01 No. The job includes providing of canvas bag/tool box for carrying/storing of tools.
Providing of solar/electrical lantern (Andslite) chargeable on both solar & electrical 220v supply.
Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipment installed at site of appropriate sizes.
WSS Dachnimall Stage 2nd.
Fabrication, providing, fitting and lowering of C class column pipe conforming to IS: 1239 of length 10 Rft; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labors, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 No. rectangular cable slots in each flange. Any modification to the column pipes /flanges required during lowering is included in the job. Size : DN 65 Rating: PN 16 Class: C (Heavy) Note: Steep head load accounted for the execution of the job. Test/inspection certificates from the Manufacturer must be produced on delivery of the item.
Fabrication, providing, fitting and lowering of C class column pipe conforming to IS: 1239 of length 10 Rft into the Production Well up to the desired depth; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labors, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 No. rectangular cable slots in each flange. Any modification to the column pipes /flanges required during lowering is included in the job. Size : DN 50 Rating: PN 16 Class: C (Heavy) Test/inspection certificates from the Manufacturer must be produced on delivery of the item.
Fabrication, providing and fitting of split type MS clamps 10 mm thick, 2 ft long and 3 inch wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts. Size : 65 mm Note: Steep head load accounted for the execution of the job.
Fabrication, Providing and fitting of 90-120 degree bend/elbow to be fabricated out of Class C GI pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with welded jointson three ends. The job includes nuts, bolts, gaskets etc complete. Size : DN 65, Class C Note: Steep head load accounted for the execution of the job.
Fabrication, providing and fitting of washout Tee. The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. The size of the Tee is given Below: ND= 65 MM Class: C Note: Steep head load accounted for the execution of the job.
Providing and laying in position cement concrete of specified grad
Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: - i. Valve type - single chamber, single/double orifice. ii. End connection - flanged ends to IS 1538 iii.Working temperature - 45oc to -150 c iv. Test pressure - body / seat 2.5 x PN v. Sealing ring - EPDM vi. Construction -ductile iron with stainless steel floats vii. Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, GI Pipe, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. The Test Certificates of Air Release Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material. Size : DN 50 Rating: PN16
Fabrication, providing, fitting and lowering of C class column pipe conforming to IS: 1239 of length 10 Rft; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labors, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 No. rectangular cable slots in each flange. Any modification to the column pipes /flanges required during lowering is included in the job. Size : DN 65 Rating: PN 16 Class: C (Heavy) Note: Steep head load accounted for the execution of the job. Test/inspection certificates from the Manufacturer must be produced on delivery of the item.
e including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1 : 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size). blocks for rising main. The job includes P/F of 6" MS bolts along with MS round 2" strip/clamp for each block. Note: Steep head load accounted for the execution of the job.
Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns. Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and Commissioning of Ductile Iron double flanged, non-rising spindle Resilient seated gate/ sluice valves (PN16) in accordance with BS 5163 part 1 and part 2 / EN 1074 Part 1 & 2/ IS 14846 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. The Test Certificates of Sluice/Gate Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material. Size: DN 65 mm Rating: PN 16 Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and Commissioning of Ductile Iron double flanged, Slanted seat swing check valve (NRV) (PN16) as per EN 1074- Part -3 / BS 5153/IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water). The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 Nos. M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with Rising main of the pumping unit at appropriate spots as per site requirement. The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. The Test Certificates of Check Valves (NRVs) mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material Size: DN 65 mm Rating: PN 16 Note: Steep head load accounted for the execution of the job.
Providing, fitting, testing and commissioning of ARV (Air Release valve) as per IS 14845 to be fitted to G.I rising Main. The ARV Shall have the following specifications: - i. Valve type - single chamber, single/double orifice. ii. End connection - flanged ends to IS 1538 iii.Working temperature - 45oc to -150 c iv. Test pressure - body / seat 2.5 x PN v. Sealing ring - EPDM vi. Construction -ductile iron with stainless steel floats vii. Coating - epoxy with corrosion resistance Besides the above works, The job also cost on account of P/F R.I gasket, GI Pipe, nuts and bolts required for installation of ARV and arrangement of gas cutter/ welding set at site. The Test Certificates of Air Release Valves mentioning the Material of Construction as above duly stamped by OEM shall be provided at the time of supply of material. Size : DN 50 Rating: PN16 Note: Steep head load accounted for the execution of the job.
Fabrication of gantry mechanism by way of providing Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded. Note: Steep head load accounted for the execution of the job.
Providing, installation and testing of manual type triple spur gear chain pulley block along with monorail geared travelling trolley having following features Gears:- The hoist shall have precision machine case Hardened alloy steel gear mounted on bearings and housed in a dust proof gear box. The lubrication of gears should be of high viscosity and temperature for longer life of gears. Load Chain:- The load chain be made of high tensile alloy steel having wear resistance and greatest mobility. The chain should be accurately collaborated, tested and have adequate in built factor of safety for safer operation. Load chain wheel:- the load chain well should be double ball bearing supported and Specially designed, perfectly machined wheel providing correct grip of load chain to makes the hoist most safe and reliable against any failure. The main specifications of C.P Block are given below : Capacity = 1 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Note: Steep head load accounted for the execution of the job.
Providing and laying of stone soling including manual compaction. Note: Steep head load accounted for the execution of the job.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1: 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size). Note: Steep head load accounted for the execution of the job.
Painting of the gantry and plate form of well using one coat of red oxide metal primer and two coats of enamel paint of different shades. Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and Commissioning of outdoor type Electric Sub Station as per the technical specifications given here under - Specifications conforming to IS: 1180 (Part 1) 2014 with latest amendments. Type: HT/LT Transformer (Level-2) Capacity:- 63 KVA Type of cooling: ONAN. Operating conditions: Input =11000 volts Output = 433 volts AC supply in 3- phase. Terminals: Input=3 No. HT Brass bush rods with insulators, washer, nuts etc. Output=4 No. LT Brass bush rods switch insulators, washers, nuts etc. Core: The core shall be of high permeability to reduce core losses and the strips shall be of suitable size and gauge. Transformer Coils: Suitable number of HT and LT coils in each leg of the core. The transformer coils shall be fabricated out of superior quality aluminum wire/strips, properly wound. The HT transformer is completely filled with suitable grade transformer oil up to required level. The job includes carriage, and all leads and lifts involved. The HT transformer shall be of reputed make from an ISO certified company as per relevant standards and a test certificate shall be provided before installation. The transformer shall also be provided with breather fill with silica jel crystals, conservator with oil level indicator, explosion vent and adequate radiator fins/ Tubes. The impedance of transformer shall be as per IS: 1180 (Part 1) 2014 with latest amendments. NOTE: The scope of the work shall include obtaining of necessary inspection/clearance certificate from the concerned department for all the required equipment. Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and commissioning of 01 No. Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT pole double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings, operating handle and 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. The 11 KV AB switches shall conform to IS: 9920 (Part-I to IV). 01 No. GO Set is to be fitted at tapping point and 01 No at HT Transformer (Substation). Testing/Inspection Certificate as per IS 9921 Part IV is mandatory and is to be produced at the time of supply of material
Fabrication, providing, fitting and lowering of C class column pipe conforming to IS: 1239 of length 10 Rft; The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be weld on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labors, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 No. rectangular cable slots in each flange. Any modification to the column pipes /flanges required during lowering is included in the job. Size : DN 65 Rating: PN 16 Class: C (Heavy) Note: Steep head load accounted for the execution of the job. Test/inspection certificates from the Manufacturer must be produced on delivery of the item.
e including curing but excluding the cost of centring and shuttering, all work upto plinth level with 1 : 2 : 4 mix (1 cement , 2 coarse sand , 4 graded stone aggregate 20 mm nominal size). blocks for rising main. The job includes P/F of 6" MS bolts along with MS round 2" strip/clamp for each block. Note: Steep head load accounted for the execution of the job.
Centering and shuttering including strutting, propping etc. and removal of form work for Foundation, footings, bases for columns. Note: Steep head load accounted for the execution of the job.
Providing and fitting G.I Channel /Angle/ Flat/ V crosses/ F- tops of sizes including clamps. The job includes fitting of Channels on two poles for the installation of insulators and safety devices, GO Set, Lighting Arrestor etc. It also includes the channels for fitting of LT Meter and LT Distribution Box. The job includes P/F of GI channels at Tapping point for installation of GO Link Set, Pin
Insulators Etc as per site requirement. Size of Channel= ISMC 75X40MM & ISMC 100x50mm Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and commissioning of 01 No. Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting of HT pole double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings, operating handle and 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs. The 11 KV AB switches shall conform to IS: 9920 (Part-I to IV). 01 No. GO Set is to be fitted at tapping point and 01 No at HT Transformer (Substation). Testing/Inspection Certificate as per IS 9921 Part IV is mandatory and is to be produced at the time of supply of material. Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation. Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type. Note: Steep head load accounted for the execution of the job.
Supply and fitting of 11 KV polymeric composite pin insulator 12 KV, 5KN, Lighting impulse 75KV Positive, and 80 KV Negative, creepage distance 320 mm. Note: Steep head load accounted for the execution of the job.
Supply, installation, erection of 9 mtrs long H.T pole of specifications ST- 410 (sp-33) . The job further includes drilling of holes for installation of various accessories, wherever required the job further includes G.I wire earthing of pole as per IEC standard. Note: Steep head load accounted for the execution of the job.
P/F of Galvanized nuts bolts of various sizes as per site requirement. Note: Steep head load accounted for the execution of the job.
Painting of poles with red oxide. Note: Steep head load accounted for the execution of the job.
P/F Danger Plate with clamps on every HT pole. Note: Steep head load accounted for the execution of the job.
Painting of poles with Aluminum Paint. Note: Steep head load accounted for the execution of the job.
Providing and fixing G.I Barbed wire for anti-climbing/ anti-climbing devices. The barbed wire shall be tightly close wrapped around the pole for 10-12 turns, commencing at 2.50m above the datum line. Note: Steep head load accounted for the execution of the job.
Providing and Fitting of PG Clamps. Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and Commissioning of Galvanized stay set with 50 X 8 mm Stay Clamp, Guy insulator (2 No.), Anchor plate (200X200X6mm), nuts and bolts, 2 No.- turn buckle, 1.8 m long, 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete. Note: Steep head load accounted for the execution of the job.
Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 0.50 sq.mm ACSR (Galvanized steel reinforced) for fitment of various accessories. Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and Commissioning of LT Distribution box for H.T transformer with 200A MCCB for incomer and 100A SFU for outgoing circuits. The LT distribution Box is to be fitted on GI Channels. Capacity of transformer: 63kVA Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and Commissioning of PRODIGY LT Meter of following specification complete with all fixtures required for fitment at site Type: 3 Phase, 4 wire Measurements offered: KWh, KVARh, KVAh, KVA Voltage : 3x240V (415v), 50HZ Ib : 40A Imax: 200A Battery: Lithium The Prodigy Meter must be fitted inside the Box, that is to be fitted on GI Channels near LT Distribution Box. Both the enclosures must be symmetrical Sealing /Inspection report of Prodigy meter from JKPDCL (Concerned) is to be submitted by the firm at the time of charging of SUBSTATION. Note: Steep head load accounted for the execution of the job.
Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required ope
nings/vents and protection (For Well) Class : IP-55 & fitted with accessories as under: a) Bus bar Chamber: The bus bar chamber shall be fitted at the top of the panel horizontally throughout the length. There shall be 3 Nos. of phase bus bar and 1 No neutral bus bar and 1 No earthing bus bar. The bus bars shall be air insulated and made-up of high conductivity COPPER (Rating 160 Ampere). All panel compartments shall be provided with suitable cable alley and vertical bus bar alley. Suitable segregation shall be provided in between bus bar chamber and adjoining compartments. The bus bar shall be PVC sleeved with color strips of red, yellow, blue and black and the same be arranged in accordance with IS-375 specs. Electrical clearances shall be maintained between phases, neutral and body as per standards b) Main Circuit Breaker (Incomer MCCB): Qty. = 02 No. No. of poles = 4 Pole Current Rating =200 Amp. Rated operational voltage = 415 V + 15 % Rated frequency = 50+/-3%Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) =50 KA, Type of release = Thermal-Magnetic Overload protection = 0.8 – 1×ln adjustable Short-circuit protection = 6-10×ln adjustable. c) Change over Switch: Qty. = 01 No. Rating =100 Amp, Type = Front operated, on load, 4 pole, 400 +15%V, 50 + 3%Hz d) Motor Back-up Protection MCCB: Qnty = 2 No. No.of poles = 3 Pole, Current Rating = 125 Amp, Rated operational voltage = 415 V +15 % Rated frequency = 50 + 3% Hz Ambient temperature = 40C˚ Ultimate S.C Breaking Cap. at (415V AC, 50 Hz) = 36KA. e)Submersible starters:-= Fully automatic star delta. Capacity = Mug 40, Power Specs = 3 Ф, 415 + 15% V, 50 + 3 % Hz. Relay range = 36-60Amp, Coil Voltage = 380 v Protection = single phasing, phase Reversal, phase unbalance (55 ± 5 V), Rated insulation voltage = 690V Terminal capacity = 120 Sq. mm with lug Or above Conformity to standard = IS/IES 60947-4-1 Qty. = 2 No’s f) Auxiliary MCCB for Heating/Lighting: Circuit Breaker = MCCB (Outgoing) Qty. = 1 No. No. of poles = 4P, Current Rating = 63Amp. Rated operational voltage = 415 V + 15 % Ultimate S.C Breaking Cap. at (240V AC, 50 Hz) = 25 KA g) Motor Protection Relay: Digital Motor Protection Relay with LCD Display for 3-phase supply with following protections suitable for the Modular Control Panel:- Protections = Thermal Overload with pre-alarm, Short Circuit, Phase Loss, Unbalance, Phase reversal, Under Current, over current, Prolong starting, Locked Rotor, Under voltage, over voltage & Earth fault. 02 No,s 01 for each starter h. M-power module for mobile starter for submersible motor 1P/3P 3 wire IVRS Languages – English , Hindi, Suitable Region- North India 02 No,s 01 for each starter. The panel shall be provided with phase indicators (03 N0,s) and digital ammeter of range 0-60 A, digital voltmeter of range 0-500 V, and digital frequency meter 01 No for each starter(Single Function Type). The enclosure of the panel shall be of excellent fit and finish, corrosion resistant and powder coated gliding hinges for smooth and noiseless movement of windows and advanced locking arrangements / angle iron or channel supports MUG 40 i) Bus bar size 160A ii) D-sine MCCB 4 pole (DN2 250N, 125-160A, 50kA) iii) Change over switch Front Operated 200A iv) D sine MCCB 3 pole (DZ1-160D ,84-125A, 36kA) v) Mug x 2 (Mug 40, 36-60Amp relay) vi) Auxiliary MCCB 63Amp vii) MM 10 of L&T (Motor Protection) Motor Protection viii) Module for mobile starter ix) Meters , (Ammeter & voltmeter) 2 No. each and Freq Meter x) Indicators LS xi) Over load and Under Voltage Minlec Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and Commissioning of 3.5-Core, XLPE, 1.1KV and 11KV grade Armoured Aluminium Cable conforming to IS: 7098 part 1st as service line from the HT transformer to control panel including necessary thimbling, crimping, taping etc. (Service line from HT Transformer and D.G Set). i) 50 sqmm, 3.5 core, LT cable Note: Steep head load accounted for the execution of the job.
Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipmen
t. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below: Size :- 16 sqmm Note: Steep head load accounted for the execution of the job.
Supply, Installation, Testing and Commissioning of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated GI earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip (25x3mm) as per relevant standards. Safe earthing electrode size : 80 mm dia, Length : 2000 mm Back fill compound : 30 kg Note: Steep head load accounted for the execution of the job.
Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 150mm, top 75mm wide, thickness 3mm with 70 Microns Zinc coating having inside arrangement for providing of power connection along with following items. 1) 3 Way Terminal Connector 20 Amp. 2) 3 No MCB 8 Amp. The job includes fabrication, providing and fitting of three arm GI structures at the top having 120˚ angle between arms and each arm having 15˚ inclination with respect to horizontal plane. Each arm should be of 2’ length and size and shape appropriate as per requirement of the luminary. The job also includes providing and fitting of required length of flexible multi strand 2 mm copper wire from each terminal connector to each holding arm. The pole is mounted on 1:2:4 Cement concreting of size not less than 2’x2’x6” (cost of concreting not included in the job) using 04 No anchor bolts of required size not less than 7” in length. The complete job includes earthing in GI Electrode as per relevant IS Code. Note: Steep head load accounted for the execution of the job.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.76 MB
BOQ_961837.xls
BOQ • 0.52 MB
Exten_eNIT_36_XX.pdf
PDF • 0.83 MB
Exten_eNIT_36_XIX.pdf
PDF • 0.82 MB
Exten_eNIT_36_XVIII.pdf
PDF • 0.82 MB
Exten_eNIT_36_XVII.pdf
PDF • 0.82 MB
Exten_eNIT_36_XVI.pdf
PDF • 0.82 MB
Exten_eNIT_36_XV.pdf
PDF • 0.82 MB
Exten_ENIT_36_XIV.pdf
PDF • 0.82 MB
Exten_eNIT_36_41.pdf
PDF • 0.83 MB
Exten_eNIT_36_XII.pdf
PDF • 0.82 MB
Exten_eNIT_36_XI.pdf
PDF • 0.83 MB
Exten_eNIT_36_X.pdf
PDF • 0.82 MB
Exten_eNIT_36_IX.pdf
PDF • 0.83 MB
Exten_eNIT_36_VIII.pdf
PDF • 0.82 MB
Exten_eNIT_36_VII.pdf
PDF • 0.82 MB
Exten_eNIT_36_VI.pdf
PDF • 0.82 MB
Exten_eNIT_36_V.pdf
PDF • 0.82 MB
Exten_eNIT_36_iv.pdf
PDF • 0.83 MB
Exten_eNIT_36_iii.pdf
PDF • 0.82 MB
Exten_eNIT_36_II.pdf
PDF • 0.82 MB
Exten_eNIT_36_I.pdf
PDF • 0.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .