| Sl No | Description | Qty | Unit | GV ELLAIYAN CONTRACTORS L2 | METHA ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00Annual Overhauling works | |||||
| 1.10 | Charges for cleaning and checking the tightness of CT, PT and control circuit terminals in 11KV, 3.3KV and 415V switchboard panels and also assistance during the testing of 217 no. of relays and attending defects, replacing defective relays, CT & PT terminal tightness checking in GRP panels, 11KV, 3.3KV, 415V switchgear panels as instructed by our maintenance engineer in charge. (including consumables cotton/banian waste, cleaning brush, rust removal spray, PU Foam and neccessary tools, hot air blower etc.,) | 210 | Nos | 420 ₹88,200 | 413 ₹86,730 |
| 1.20 | Charges for checking of the limit switch gear mechanism, manual engage lever assembly, lubrication in the actuator and also topping up if necessary,cleaning the actuator and checking of the power and control terminal tightness. Removing the power and control cables for changing the orientation of the actuator, & during overhauling of the valves to be carried out by Turbine maintenance and Boiler maintenance. Reconnecting the power & control cables and E-pac assembly after completion of overhauling works by TM/BM and checking the operation of both local and remote as instructed by our maintenance engineer incharge. (including consumables cotton/banian waste, rust removal spray, cleaning brush, PU Foam and neccessary tools, hot air blower etc.,) | 120 | Nos | 420 ₹50,400 | 413 ₹49,560 |
| 2.00Cleaning & Testing of Power modules in Variable Frequency Drives of ID FAN. | |||||
| 2.10 | Removing & cleaning of Power modules & Voltage snubber circuits from VFD Thyristor bridge panel after disconnection of Gate, Cathode, NTDA card connection & pulse transformer circuit. Testing of each Thyristor cell in Power module and refixing of power module and Voltage snubber circuit in VFD Thyristor bridge panel reconnecting the same.(including consumables cotton/banian waste, rust removal spray, cleaning brush, PU Foam and neccessary tools, hot air blower etc.,) | 96 | Nos | 2,000 ₹1,92,000 | 1,993 ₹1,91,328 |
Tender Value
Refer Docs
EMD Value
₹3,300
Closing Date
9 Jul 2025, 2:00 pmClosed
SEES NCTPS-II
OFFICE OF SEES
Sp.135 NCTPS II ES circle MRT Division Unit II Annual Overhauling 2024 25 Maintenance work contract under open tender basis
2025_EB_577254_1
CE NCTPS II SE ES MRT SPEC NO 135 24 to25
Open Tender
Electrical and Maintenance Works
45 days
NCTPS-II
AS PER TENDER SPECIFICATION
2 documents required · 2 mandatory
₹0
₹3,300
Yes
17 Jun 2026
3 Jul 2025
10 Jul 2025
3 Jul 2025
9 Jul 2025
3 Jul 2025
Amount
Annual Overhauling works
Charges for cleaning and checking the tightness of CT, PT and control circuit terminals in 11KV, 3.3KV and 415V switchboard panels and also assistance during the testing of 217 no. of relays and attending defects, replacing defective relays, CT & PT terminal tightness checking in GRP panels, 11KV, 3.3KV, 415V switchgear panels as instructed by our maintenance engineer in charge. (including consumables cotton/banian waste, cleaning brush, rust removal spray, PU Foam and neccessary tools, hot air blower etc.,)
Charges for checking of the limit switch gear mechanism, manual engage lever assembly, lubrication in the actuator and also topping up if necessary,cleaning the actuator and checking of the power and control terminal tightness. Removing the power and control cables for changing the orientation of the actuator, & during overhauling of the valves to be carried out by Turbine maintenance and Boiler maintenance. Reconnecting the power & control cables and E-pac assembly after completion of overhauling works by TM/BM and checking the operation of both local and remote as instructed by our maintenance engineer incharge. (including consumables cotton/banian waste, rust removal spray, cleaning brush, PU Foam and neccessary tools, hot air blower etc.,)
Cleaning & Testing of Power modules in Variable Frequency Drives of ID FAN.
Removing & cleaning of Power modules & Voltage snubber circuits from VFD Thyristor bridge panel after disconnection of Gate, Cathode, NTDA card connection & pulse transformer circuit. Testing of each Thyristor cell in Power module and refixing of power module and Voltage snubber circuit in VFD Thyristor bridge panel reconnecting the same.(including consumables cotton/banian waste, rust removal spray, cleaning brush, PU Foam and neccessary tools, hot air blower etc.,)
GV ELLAIYAN CONTRACTORS (BID ID -1394738)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid