Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC AT DHORI STAFF QTR PO DHORI DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | Rejected-Technical AT KARGALI BAZAR PO BERMO DIST BOKARO PIN 829104 | BERMO | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical Bid not be opened as per NIT terms | |
| 3 | Rejected-Technical 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | - | Rejected-Technical Bid not be opened as per NIT terms |
Tender Value
₹22.4 L
EMD Value
₹28,100
Closing Date
2 Sept 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (EnM)
Office of the General Manager, Dhori Area
Repair and maintenance of 11 kV OH line under Dhori (K), Dhori Area
2024_CCL_315393_2
GM(D)/SO(EnM)/DA/2024-25/27
Open Tender
Electrical and Maintenance Works
Item Wise
28 days
Dhori (K), Dhori Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹28,100
4 Nov 2024
19 Aug 2024
3 Sept 2024
20 Aug 2024
2 Sept 2024
20 Aug 2024
20 Aug 2024 - 24 Aug 2024
Amount
Part A: Gorango Colony to Oriya Dhawrah
Supply and errection of 11 KV disc insulator for 11 KV over head line with galvenised insulator fittings,ball and sockets type and complete with galvenised strain clamps bolts nuts washer etc as required..
Supply and erection of 11 KV pin insulator complete with large steel head G.I. pin ,nuts,washer etc as required..
Supply and erection of galvanised stay set for 11 K.V. over head line complete with 19/20 mm dia x1.8 mtr. Long stay rod ancore plate size 45 cm x 45 cm x 7.5 mm thick, thimble stay clamps, turn buckle (20mmx6.00 mm ), 7/4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement:3 sand:6 graded stone 40 mm nominal size)foundation including excavation and refilling etc as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/ 33 KV as required
Cleaning jungle including uprootingh of rank vegitation,grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Erection of all aluminium conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required
Dismantling of 11 KV over head lines comprising of aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required Above 10.00 metre and upto 12.00 metre
Reconnection of OH jumper
Supply and fixing of one phase male/female/WireNet fixed contact for repairing of 400 Amp., 11 KV grade verticle type Gang operating switch.
Dismantling of old gang switches
Supply and fixing of 02 nos. 400 Amp, 11 kV heavy duty Gang Operating Switch
Supplying and erection of a set of cross bracing FRLSame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Erection of G.I. wire no 8 SWG includig binding etc as required.
Supply of 8 SWG G.I. wire.
Shifting of tubler/rail/cement pole from store to the site and vice-versa(pole size 10 to 12 Mtr.)
Errection of craddle guard.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Supply and erection of 30 A aerial fuse complete as required,
Part B: Dhori Distribution Substation to Ghoda Nala
Supply and erection of 11 KV disc insulator for 11 KV over head line with galvanised insulator fittings,ball and sockets type and complete with galvanised strain clamps, bolts, nuts, washer etc as required..
Supply and erection of 11 KV pin insulator complete with large steel head G.I. pin ,nuts,washer etc as required..
Supply and erection of galvanised stay set for 11 K.V. over head line complete with 19/20 mm dia x1.8 mtr. Long stay rod ancore plate size 45cmx45cm x7.5 mm thick ,thimble stayclamps,turn buckle (20mmx6.00mm ),7/4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1;3;6(1 cement:3 sand:6 graded stone 40 mm nominal size)foundation including excavation and refilling etc as required.
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/ 33 KV as required
Cleaning jungle including uprooting of rank vegitation,grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Erection of ACSR conductor of 7/3.40 mm to 7/4.00 mm diameter and above including binding etc. as required
Dismantling of 11 K.V. over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supply and fixing of one phase male/female/WireNet fixed contact for repairing of 400 Amp., 11 KV grade verticle type Gang operating switch.
Dismantling of pole embedded in cement concrete foundation etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required Above 10.00 metre and upto 12.00 metre
Erection of G.I. wire no 8 SWG includig binding etc as required.
Supply and erection of 30 A aerial fuse complete as required,
Supply of 8 SWG G.I. wire.
Shifting of tubular/rail pole from store to the site (pole size 10 to 12 Mtr.)
Shifting of dismantled tubular/rail pole from site to store (pole size 10 to 12 Mtr.)
Erection of craddle guard.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Supplying of channel iron 50 mm X 6 mm (7.14 kg per metre) cross arm for single 11KV over head line conductors complete with M.S. flats iron, clamps, bolts, nuts aincluding drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Connection of OH line Jumper (During preventive maintainence activity)
Numbering, voltage grading and mentioning of feeder name with standard black Japan paint
Total impact of GST for the purpose of CTC
M/S A N TRADERS
M/S KUMAR ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .