Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹10.7 L+₹73,340 (7.33%)Admitted-Finance NO 115 KAMARAJAR NAGAR PUDUPATTINAM KALPAKKAM 603102 | CHENGALPATTU | TAMIL NADU | 603102 | L2 | Admitted-Finance | |
| 3 | L3₹12.6 L+₹2.6 L (26.1%)Admitted-Finance NO 74 SADRAS MAIN ROAD NARASANKUPPAM VILLAGE 603109 MULLIKULATHUR POST THIRUKKAZUKUNDRAM TALUK CHENGALPATTU DISTRICT | CHENGALPATTU | TAMIL NADU | 603109 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | VNV ENGINEERS AND CONSTRUCTION L3 | K.GANESH L2 | D VELU AND SONS L1 |
|---|---|---|---|---|---|---|
| 1.00Earthwork excavation by manual means for foundation, substructures, plinth beam, cess pits & trenches, all kinds of foundation etc., in all types of soil like hard gravelly soil, sandy soil for the following depth from average ground level upto the required founding level, line and grades in both dry and wet conditions including shoring, strutting, bailing out of water if necessary, levelling and ramming the bottom of trenches, dressing of sides, stacking the excavated materials away from the edge of trenches, refilling the sides of foundation as required with selected excavated earth and depositing / disposing the surplus excavated earth (Disposed soil to be leveled by breaking clods, if any and neatly dressed and leveled) within the lead specified below all complete as per specifications and as directed by the Engineer-in-Charge. | ||||||
| 1.01 | All kinds of soil with depth upto 1.5m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres. | 30 | Cu.m. | 300 ₹9,000 | 550 ₹16,500 | 250 ₹7,500 Lowest |
| 1.02 | All kinds of soil with depth exceeding 1.5m but not exceeding 3m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres. | 15 | Cu.m. | 420 ₹6,300 | 650 ₹9,750 | 300 ₹4,500 Lowest |
| 2.00Providing and laying the following sizes PVC water supply line with Finolex / Varun / Truebore or approved equivalent make PVC pipes suitable for 6 kg/sq.cm pressure and specials conforming & marked to IS:4985 including jointing with PVC jointing compound, laying and fixing the pipes in the excavated trenches, cost of all types of specials such as tees, reducers, coupler, reducing bushes, threaded adaptor, elbow, tail pieces, caps etc., and testing the line as directed by the Engineer-in-Charge. | ||||||
| 2.01 | 40mm outer dia PVC pipe | 30 | Metres | 200 ₹6,000 | 200 ₹6,000 | 150 ₹4,500 Lowest |
| 2.02 | 50mm outer dia PVC pipe | 30 | Metres | 200 ₹6,000 Lowest | 220 ₹6,600 | 200 ₹6,000 Lowest |
| 2.03 | 63mm outer dia PVC pipe | 60 | Metres | 260 ₹15,600 | 350 ₹21,000 | 250 ₹15,000 Lowest |
| 2.04 | 110mm outer dia PVC pipe | 30 | Metres | 530 ₹15,900 | 550 ₹16,500 | 500 ₹15,000 Lowest |
| 2.05 | 160mm outer dia PVC pipe | 10 | Metres | 1,000 ₹10,000 | 1,200 ₹12,000 | 900 ₹9,000 Lowest |
| 3.00 | Cleaning the over head water tanks of various capacities at different elevations over the roof of building / laboratories all as directed by the Engineer-in-Charge. | 1,500 | Sq.m. | 15 ₹22,500 | 8 ₹12,000 Lowest | 10 ₹15,000 |
Tender Value
₹10.9 L
EMD Value
₹21,760
Closing Date
10 Dec 2025, 11:30 amClosed
Chief Engineer, CEG
Civil Engineering Group, CDO Building, IGCAR, Kalpakkam - 603 102
Maintenance of water supply, Sanitary installations and Operation of sewer network in FBTR Complex during the year 2026-2027.
2025_IGCAR_885125_1
CEG/IGC/2138/2025
Open Tender
Civil Works - Buildings
Item Rate
365 days
Kalpakkam
8 documents required · 8 mandatory
₹0
₹21,760
13 Jan 2026
12 Nov 2025
11 Dec 2025
13 Nov 2025
10 Dec 2025
14 Nov 2025
Amount
All kinds of soil with depth upto 1.5m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres.
All kinds of soil with depth exceeding 1.5m but not exceeding 3m below average Ground level and disposing surplus excavated earth upto a lead of 50 metres.
Providing and laying the following sizes PVC water supply line with Finolex / Varun / Truebore or approved equivalent make PVC pipes suitable for 6 kg/sq.cm pressure and specials conforming & marked to IS:4985 including jointing with PVC jointing compound, laying and fixing the pipes in the excavated trenches, cost of all types of specials such as tees, reducers, coupler, reducing bushes, threaded adaptor, elbow, tail pieces, caps etc., and testing the line as directed by the Engineer-in-Charge.
40mm outer dia PVC pipe
50mm outer dia PVC pipe
63mm outer dia PVC pipe
110mm outer dia PVC pipe
160mm outer dia PVC pipe
Cleaning the over head water tanks of various capacities at different elevations over the roof of building / laboratories all as directed by the Engineer-in-Charge.
Labour charges only for maintenance of wash basin / lab sinks including removing the choke and cleaning the drainage pipe by roding, repairing waste coupling, taps, basin inlet connection and refixing the brackets etc., complete all as directed by the Engineer-in-Charge.
Labour charges only for maintenance of wall urinals including removing the choke and cleaning the drainage pipe and traps by roding, repairing, replacing rubber gasket and refixing the brackets etc., complete all as directed by the Engineer-in-Charge.
Labour charges only for maintenance of high / low level flushing cistern including repairing cistern siphon, flush pipe, ball valves, basin inlet connection, handle etc., complete all as directed by the Engineer-in-Charge.
Providing and fixing 15mm CP brass Angle valve (screw down / pressing type) ‘Jaquar / Metro or other approved equivalent make’ including removing the damaged valves etc. complete all as directed by the Engineer-in-Charge.
Providing and fixing 15mm CP brass wall mounted Elbow operating bib taps Metro/Vijay or approved equivalent make including removing the damaged tap and handing over to IGCAR pump house / place specified etc. complete all as directed by the Engineer-in-Charge.
Water supply line Burst / Breakage: Attending the following works, earthwork excavation to ascertain the type of leak including extra length and width of excavation required as per site condition to facilitate removal of damaged / broken pipes, specials and its rectification, dewatering, removing the slush from the trenches, conveying of the earth and slush away from the trenches to prevent over burden for the trench, conveyance of pipes, specials and other accessories, de-water pumps, suction and delivery lines to the work site from the section stores and installation of de-water pumps and suction delivery lines etc., cutting the burst / broken pipes and removing the pipes from the mains and re-installing the new pipes, jointing and testing the pipeline and re-filling the excavated trenches in to the original condition etc. complete. Note: Necessary material viz : pipes, specials and jointing materials will be measured under relevant item.
80mm dia to 100mm dia pipes.
150mm dia to 200mm dia pipes.
250mm dia to 300mm dia pipes.
Removing the choke and cleaning the sewer lines of 100mm to 300mm Dia stone ware / CI pipes including opening the CI manholes cover of the chamber, inserting sewer cleaning rod through one chamber, and removing at the other chamber, collecting and disposing the chocked materials like root, grit, sand etc., including cleaning the chamber, gully and pipes, general cleaning of the shaft area of the building s etc., complete all as directed by Engineer-in-Charge.
Operating the VNC pumps, Sewage submersible pumps, Monoblock pumps, Sludge pumps, De watering pumps, Rotors and valves etc., in the Sewage Treatment plant and Lift station including cleaning and removing the floating objects from screen cum suction well, inlet chamber, influent chamber, oxidation ditch, settling tank, chlorination chamber and oxidation pond etc., including cleaning of the bar screens , removing of dried sludge from sludge drying beds, operation of slurry pumps and valves for recycling sludge, and balling out sewage water from the letting out effluent etc..,complete in the sewage treatment plant / sewage lift station of IGCAR and as directed by the Engineer-in-Charge. Note: Contractor has to engage a minimum 2nos. of operators in each shift every day throughout the year including holidays (Timing of shifts - General shift 9:00 hours to 17:30 hours ; 1st shift 6:00 hours to 14:00 hours ; 2nd shift 14:00 hours to 22:00 hours; 3rd shift 22:00 hours to 6:00 hours). If any short fall found during the contract period, he will be penalised at the rate of 1.00 job / operator / day shall be deducted from the RA bills.
Lifting & Transporting the Liquefied sludge from Sewer chambers /Collection Well in FBTR through a container lorry/Tanker loading the sludge and unloading by using tanker lorry of capacity 4000 litres and disposing through mechanical means to STP Collection Chamber, including all tools & Equipment’s as directed by the Engineer-in-charge. Note: The rate shall include the cost of hire charges for tanker/Lorry and crew and required tools and equipment etc. complete
Supplying and disposing the good quality of bleaching powder in the drinking water / let out treated sewage effluents for the purpose of disinfections at Sump / Sewage treatment plant or places as directed, including cost of bleaching powder, transport and required man power for dosing etc., complete all as directed by the Engineer-in-Charge. Prior approval shall be obtained from the Engineer-in-Charge by producing samples regarding quality and brand before procurement.
Supplying and fixing of following size of uPVC pipe of SCH 40 of make ASTRAL/PRINCE/Finolex or approved equivalent make conforming to relevant ASTM D 1785 standards including all UPVC Plain & Brass threaded fittings confirmed to ASTM D 2466/ ASTM D 2467, fixing the pipe with clamps at 1.00 m spacing including cutting, threading and jointing with uPVC cement solvent, Teflon tape making necessary opening/chasing of the wall, flooring and making the work place to the original condition etc., and testing the line as directed by the Engineer-in-Charge.
20mm nominal size uPVC pipe of SCH 40
25mm nominal size uPVC pipe of SCH 40
32mm nominal size uPVC pipe of SCH 40
40mm nominal size uPVC pipe of SCH 40
50mm nominal size uPVC pipe of SCH 40
80mm nominal size uPVC pipe of SCH 40
Providing and fixing following dia uPVC ball valve pasting/thread type of make ASTRAL/PRINCE/Finolex or approved equivalent make including the cost of labour charges, pasting solution etc., complete all as directed by the Engineer-in-Charge.
15mm nominal size uPVC Ball vale
20mm nominal size uPVC Ball vale
25mm nominal size uPVC Ball vale
32mm nominal size uPVC Ball vale
40mm nominal size uPVC Ball vale
50mm nominal size uPVC Ball vale
65mm nominal size uPVC Ball vale
Providing and fixing following dia PVC ball valve pasting/thread type ASTRAL/PRINCE/Finolex or approved equivalent make including the cost of labour charges, pasting PVC solution etc., as directed by the Engineer-in-Charge.
160mm nominal size PVC ball valve
110mm nominal size PVC ball valve
90mm nominal size PVC ball valve
63mm nominal size PVC ball valve
50mm nominal size PVC ball valve
Providing and fixing in position at all levels 1:1.5:3 concrete support block for pipe line of size 250x150x150mm fixed with two numbers of M16 bolts at c/c distance of 75mm/100mm with center dispersion to seat the pipe including the cost of bolt, shuttering/mould, casting, laying at site all materials etc., complete as directed by the Engineer-in-Charge
Providing and fixing Coloured vitreous china flat back half stall urinal size 580 x 380 x 350mm Hindware or Parryware Newmagnum model or Equivalent approved make with PVC 15mm Inlet connection, Push cock, 15mm stop cock, C.P. brass spreaders, 32mm Urinal waste coupling with Dome grating, and clamp etc. including making G.I water line connection complete all as per drawings and specifications and as directed at site. (Only G.I. pipes will be paid under relevant Item)
Providing and fixing SS gratings of 100mm dia including chipping the mortar if any and making the surface good etc. complete all as directed by the Engineer-in-Charge.
Attending and arresting the leakages in the floor traps including dismantling the surrounding PCC to required size and making holes on the wall and changing the trap and fixing the waste lines, providing PCC and plastering to the original shape complete all as directed by the Engineer-in-Charge.
Removing the chokes in IWC / EWC / Gully trap /Floor Trap by roding or by using choke remover including removing, collecting and disposing chocked materials etc., complete all as directed by Engineer-in-Charge.
Providing and fixing white vitreous Counter top wash basin of size 610mm x 450mm oval or round pattern (Parryware/Hindware or approved equivalent) including making all connections but excluding the cost of fittings etc. complete all as per specifications and as directed by the Engineer-in-Charge
Providing and fixing PVC low level / High level white colour flushing cistern 10 litres capacity (Hindware or approved equivalent make) with flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures etc. complete as per specifications and as directed by the Engineer-in-charge.
Providing and fixing PVC inlet connection pipes heavy quality suitable for hot and cold including CP brass unions and nuts 15mm dia 450mm long as per specifications and as directed by the Engineer-in-Charge.
Providing and fixing liquid soap dispenser in PVC container VEGA or approved equivalent make with all accessories including necessary screws for fixing complete all as directed by the Engineer-in-charge.
Providing and fixing Heavy Quality C.P Brass Health Faucet with 1.50metres flexible hose (Hand Shower) of Jaquar continental model or approved equivalent make and type complete all as per specifications and as directed by the Engineer-in-Charge (Samples to be got approved by the Engineer-in-Charge)
Providing and fixing double Tubular scaffolding system using H-Frames / APS system or (cup lock type) on the exterior side made with 40mm dia M.S. tube 1.5m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in-Charge. Note : 1. The elevation area of the scaffolding shall be measured for payment purposes. 2. The payment shall be made once irrespective of duration of scaffolding. 3. The scaffolding system drawing shall be got approved by Engineer-in-Charge. 4. The contractor has to observe all safety procedure while working on heights as per I.S. 3696 (Part-I) (Safety Code for scaffolds). 5. Screen of suitable material shall be provided to the full height of scaffolding and securely tied to protect falling objects coming out during the work is in progress. 6. Necessary aluminium / M.S. ladder shall be provided at the cost of the contractor, to the full height of scaffolding at required location around the building to enable Departmental Supervisor/Engineer climb up and closely watch the repair work of the building.
Providing and fixing the new 25mm dia PTMT / PVC ball cock with epoxy coated rod of 450mm length and HDPE ball PRAYAG or other approved equivalent make bearing ISI mark with all accessories in overhead water tanks and other required location without interfering regular water supply including removing existing the damaged ball cock and returning to Departmental stores, fixing new ball cock with GI specials if required etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing PVC nahani trap, 110mm inlet and 75mm outlet of ‘Finolex / Prince or other approved equivalent make’ conforming to the relevant IS code heavy quality of self-cleaning design with CP/SS grating of 125mm dia with perforated holes including embedding in cement concrete 1:2:4 forming circular holes by providing and fixing 110mm OD PVC pipes of required height up to floor level, levelling and rendering smooth, making good the floor and wall etc., complete as per specifications. (Rate shall include cost of PVC pipe, cement concrete and it shall not be paid extra.)
Providing and fixing Heavy Quality C.P. brass 15mm dia Bib cock Jaquar continental / Parryware coral model or approved equivalent as per specifications and as directed by the Engineer-in-Charge. (Samples to be got approved by the Engineer-in-Charge)
Dismantling tile work (thickness of tile upto 25mm) in floors and roofs laid in cement mortar at all levels including stacking material within 50 metres lead complete all as per specifications and directed by the Engineer-in-charge.
Providing and fixing 1st quality ceramic floor/wall tiles conforming to IS 15622 of approved make in approved size, shade and colour (as approved by Engineer-in-charge), free from cracks, fissures & flakes with straight edges & perfect corners fixed at right angles as per design and pattern required over a bed of 20mm thick bed of cement mortar 1:4 using crushed stone sand (in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 using crushed stone sand), including machine / hand cutting to required size and shape, pointed neatly with white cement mixed with coloring pigment to match colour of tile, properly finished in all respects, curing, cleaning the surface neatly at the time of handing over the area, all materials and labour complete. Note: The sample tile shall be got approved by the Architect/Engineer before procurement.
In flooring fixing with 20mm thick bedding in cement mortar 1:4 using crushed stone sand.
In Dados and skirting laid over 12mm thick backing in cement mortar 1:3 using crushed stone sand.
Providing and fixing White Vitreous Indian water closet of Orissa pattern W.C. pan of size 580x440mm with integral type foot rest with 100mm China ware P or S trap, One no. 10 litre High level or low level white PVC flushing cistern with flush pipe & bend with manually controlled device (handle lever) conforming to IS:7231, PVC 15mm Inlet connection, with all fittings and fixtures, 15mm stop cock complete including all connection, embedding in position commissioning, cleaning etc. all as per drawings and specifications and as directed at site.
Providing and fixing colour vitreous china European type water closet pan of approved pattern of Hindware or approved equivalent make, excluding the cost of other fittings but including necessary screws and jointing complete etc. all as per specifications and as directed by the Engineer-in-Charge
Providing and fixing C.P. Brass toilet paper roll holder Recessed type approved with Brass C.P screws of Jaquar make or approved equivalent make and type as directed by the Engineer-in-Charge complete.
Providing and fixing C.P Brass towel ring complete fixed to walls with 30mm CP brass screws with concealed fitting arrangement of Jaquar make all as directed by the Engineer-in-Charge.
Providing and fixing Heavy Quality C.P Brass SWAN NECK Pillar cock of Jaquar continental model or approved equivalent make and type complete all as per specifications and as directed by the Engineer-in-Charge (Samples to be got approved by the Engineer-in-Charge)
Providing and fixing white vitreous china laboratory sink of size 600 x 450 x 200mm with C.I. brackets, 40mm C.P. brass trap with C.P. brass unions complete including painting the fittings and brackets with 3 coats of white enamel paint over a coat of primer, cutting and making good the walls wherever required complete all as per specifications and as directed by the Engineer-in-Charge
Providing and fixing 15mm C.P Brass Urinal spreader size with 12mm (1/2 inch) BSP thread and shapes, weighing not less than 60 gms of PLATO or approved make and type.
Providing and fixing White / Coloured solid plastic seat cover (Hindware/ Parryware make or approved make suitable to existing EWC) with lid including CP Brass / SS bolts, screws etc. for pedestal type W.C. pan complete as per specifications and as directed by the Engineer-in-Charge.
Providing and laying plain cement concrete 1:2:4 using 20mm maximum size graded aggregates and crushed stone sand including mechanical mixing, transporting and placing in required position, ramming, compaction, levelling, curing, shuttering, dewatering if any, complete all as per specification for levelling courses in foundation for walls, footings, floor drains etc., encasing pipes and other required works directed by Engineer-in-Charge complete all as per specifications.
Providing plastering to the external surfaces of brickwork/concrete at all elevations/levels in cement mortar 1:5 using crushed stone sand, 15mm thick including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications and as directed by the Engineer-in-Charge.
Providing and constructing brick masonry at all lifts using well burnt stock bricks / Flyash bricks in cement mortar 1:6 using crushed stone sand including suitable scaffolding, raking out joints, curing complete as per specifications and drawings for foundation, superstructure, etc. for the following
Above FFL to Five floor level [Each floor height 3.75m]
Providing and fixing 100mm dia Shower rose with arm Parryware G0132A1 type and make all as per specifications and as directed by the Engineer-in-Charge. (Samples to be got approved by the Engineer-in-Charge)
Supplying and fixing in position single leaf/double leaves of 28mm thick non decorative type factory made Wood Polymer Composite (WPC) solid door shutters confirmed ti IS:2380 latest having density of minimum 650 Kg/Cum, screw withdrawal strength of 1500 N at face and 1000 N at edge, water absorption less than 1%, Class A fire resistance and tensile strength greater than 12 MPa including fixing required hardware fittings, fixing door using required screws, including providing recessions for hinges, finishing all edges with mixture of PVC powder & solvent for smooth finish, The door shutter shall be fixed with the following hardware fittings: - a) 4 Nos. of 75 mm long stainless steel butt hinges of GARG brand bearing ISI mark with suitable stainless steel screws. b) Two numbers of 125mm long anodised of make aluminium D handle Classic/Crown or approved equivalent as per IS - 208 bearing ISI mark with suitable CP screws. c) Two numbers of 150mm long stainless steel baby latch type/cranked type tower bolt with suitable CP screws. d) One number of 50mm long solid PVC door buffer with 75mm long CP screws. Note: - 1) All furniture fittings shall be of approved quality and make. 2) The rate quoted shall be inclusive of fixing of door shutters with required hardware fittings as detailed above. 3) The PVC Integral Foam shall be factory manufactured solid section of light weight sheet with fine & homogeneous closed cell structure with smooth, glossy, hard surface finish on both sides. 4) The entire door shall be jointless shutter. 5) The sizes shall be approximately 700 mm x 2100mm, however exact dimensions shall be measured at site before manufacturing etc., all complete as per specifications and as directed by Engineer-In-Charge.
Supplying and fixing in position 75mmx50mm size Wood Polymer Composite (WPC) solid door frame confirmed ti IS:2380 latest having density of minimum 850 Kg/Cum, screw withdrawal strength of 2000 N at face and 1600 N at edge, water absorption less than 1%, Class A fire resistance and tensile strength greater than 12 MPa including fixing required hardware fittings, required screws, etc., all complete as per specifications and as directed by Engineer-In-Charge.
Providing and fixing 5mm thick first quality mirror of required size with anodized aluminium section frame work of size 30 x 20mm, backing the mirror with 4mm thick AC plain sheet painting two coats of plastic emulsion paint over a coat of primer, fixing the entire unit on the wall surface with necessary screws etc. complete all as directed by the Engineer-in-Charge.
Providing and fixing the following sizes of LEADER make gun metal full way gate valves female ends screwed bonnet integral seat non raising spindle class I, ISI marked to IS:778 tested to 20 kg/sqcm hydraulic pressure etc., complete all as per specification and as directed by the Engineer-in-Charge.
25mm nominal bore
40mm nominal bore
50mm nominal bore
80mm nominal bore
Providing and fixing Heavy Quality C.P Brass Waste coupling 32mm Dia and minimum 79mm length Half threaded or Full threaded as per requirement for wash basin and sink, of approved make, size and quality complete all as directed by Engineer-in-Charge
Providing and fixing Heavy Quality C.P Brass Waste coupling 38mm Dia and minimum 83mm length Half threaded or Full threaded as per requirement for wash basin and sink, of approved make, size and quality complete all as directed by Engineer-in-Charge
Providing and fixing 32mm dia CP brass waste coupling for urinal with hinged dome gratings Metro or approved equivalent make with or without overflow with check nut complete all as directed by the Engineer-in-Charge.
Providing and fixing heavy quality 15mm CP brass Bib Taps Two way bib cock Parryware G0634A1 or approved equivalent etc., complete all as directed by Engineer-in-Charge.
Dismantling Plain Cement concrete by manually / by mechanical means at all levels, carefully without damaging adjacent structures including disposal of debris with 50m lead, labour, tools required etc. complete in all respects as per specifications and directed by the Engineer-in-charge.
Dismantling of RCC works at all levels by manually / by mechanical means, including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead as per specifications and directed by the Engineer-in-charge.
Dismantling brick work in cement mortar at all levels by manually / by mechanical means, carefully without damaging adjacent structures including stacking of serviceable materials and disposal of unserviceable materials within 50m lead all as per specifications and directed by the Engineer-in-charge.
Providing and constructing Gully Chamber of internal size 300x300mm including providing, supplying and fixing 150 x 150mm stoneware gully trap with CI grating including excavation in all types of soils, backfilling, embedding in plain cement concrete 1:4.5:8 using 40mm size granite aggregates and crushed stone sand and constructing the above chamber with 115mm thick brick work in cement mortar 1:4 using crushed stone sand with well burnt chamber bricks, plastering over both internal and external faces of brick work with cement mortar 1:3 using crushed stone sand, 12mm thick finished smooth with a floating coat of neat cement on both faces, providing and fixing CI cover with frame of 300 x 300mm size (inside) the weight of cover to be not less than 4.5 kg and frame to be not less than 2.70 kg as per standard design complete all as per specification and as directed by the Engineer-in-Charge.
Conveying the surplus excavated earth & debris, boulders and spoil by mechanical means and depositing at places inside DAE installation identified as Dumping yard as per requirement with a lead specified below including loading, unloading, breaking clods, levelling all complete as per specification and as directed by the Engineer-in-Charge. Note: 1) The rates in respect of this Item are applicable for the NET Quantities arrived at after making deductions for voids @ 20% in respect of soil and @ 50% in respect of Rock from the corresponding Stack / Truck measurements. 2) The earth shall be dumped well inside the Dumping yard and not over approach pathway road.
Lead charges for lead Exceeding 4 kilometre but not exceeding 5 kilometre
Providing and fixing 15mm C.P. Brass urinal push cock `KOHINOOR / Jaquar / Parryware or other equivalent approved make including removing the damaged push cock etc., complete all as directed by the Engineer-in-Charge. (Samples to be got approved by the Engineer-in-Charge)
Repairing the flushing cistern by supplying and fixing the following spares to flushing cistern including removing the existing flushing cistern, replacing the worn out spares with new spares and refixing the same in original position with working condition & returning the retrieved worn out fittings to IGCAR pump house stores etc. ., all complete as directed by the Engineer-in-Charge.
15mm dia PVC ball cock with suitable PVC float
32mm dia PVC syphon
15mm PVC handle knob with pulling rope.
50mm dia rubber washer
Brackets kit
Flush bends for EWC
Repairing the Slimline type Parryware DUAL flushing cistern by supplying and fixing the following spares to flushing cistern including removing the existing flushing cistern, replacing the worn out spares with new spares and refixing the same in original position with working condition etc., all complete as by the Engineer-in-Charge.
32mm dia PVC syphon for DUAL flushing cistern
15mm PVC top button for DUAL flushing cistern
Supplying and fixing in position of heavy quality Cast Iron manhole frame and cover, steps etc of specified weight for the inspection chamber, valve chamber etc. all as per specifications and as directed by the Engineer-in-Charge.
K.GANESH (BID ID -3330296)
VNV ENGINEERS AND CONSTRUCTION (BID ID -3328438)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.47 MB
2138FormsACDFGHforfillinganduploading.xls
Tender Documents • 0.08 MB
2138technicalbid.pdf
Tender Documents • 2.15 MB
BOQ_930347.xls
BOQ • 0.34 MB
2138Undertakingsandformoftender.pdf
Tender Documents • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .