GE Amritsar
GE AMRITSAR PIN 143001
REPAIR / MAINTENANCE OF WINTER APPLIANCES OF OLD AMRITSAR CANTT, GG FORT AND VAD AT AMRITSAR
2022_MES_556307_1
GE/ASR-58/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE Amritsar
Class E Category b i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹20,960
30 Dec 2022
7 Oct 2022
5 Nov 2022
7 Oct 2022
4 Nov 2022
22 Oct 2022
Amount
Geyser Material and labour for maintence of storage type electric water heater geyser capacity 25/35/50 litre comprising of the following activities:- (a) Inspection taking down, opening, dismantling , descaling, brushing and cleaning of storage tank and examining of water tightness of storage tank after cleaning and descaling and refixing in position. (b) Check and connect earth continuity of electric items. (c) checking and adjustment of pressure release valves. (d) Cleaning and maintainance and refix thermostat and thermal cut out and its functioning. (e) Checking of dead weight, cleaning and seal and ensuring that vent hole is not fuctioning. (f) Visual examination of fusibie plug. (g) Testing of geyser after repair. Complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing unserviceable heating element from geyser and supply and fixing new heating element ISI Marked any type (Triangular/Round cup etc.) 1.5/2 KW Capacity of COPPER/INCOLOY material including necessary element connection as required at site and testing ; Complete all as specified and as directed by Engineer-in-Charge. (petty item such as nut ,bolt, clamps etc are deemed to be included in unit rate)
Taking down carefully existing unserviceable thermostat and supply and fixing new thermostate ISI marked for geyser any capacity with necessary connection and heating ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existingunserviceable thermal cut out and supply and fixing new thermal cut out ISI marked for geyser any capacity with necessary connection and heating ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully existing unserviceable indicator lamp and supply and fixing new indicator lamp to geyser of any size and shape ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of GI hexa nipple (set of two) of size 15 mm having screwed both end with fine thread ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of inner shell of suitable size made of stainless steel sheet of Fe 305 22 SWG ISI Marked can bear pressuure upto 0.8MPa suitable for geyser of any type/Make and 25/35 litres capacity complete with all suitable accessories such as thermal insulation etc ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of inner shell of suitable size made of stainless steel sheet of Fe 305 22 SWG ISI Marked can bear pressuure upto 0.8MPa suitable for geyser of any type/Make and 50 litres capacity complete with all suitable accessories such as thermal insulation etc ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down existing unserviceable inner base assembly supply and fix new inner base assembly complete with inlet ,outlet, thermostat pipes with drain plug and screw including clamps for holding the elements, nuts, bolt ,washer etc, ISI Marked for geyser of any type/Make and 25/35/50 litres capacity ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of copper wire, 3 core, flexible type of size 2.5 Sq mm etc ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down existing unserviceable bottom cover plate (two halves) and fix with new bottom cover plate with matching colour of geysers of any type/Make and capacity ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down existing unserviceable Non return valve and supply and dixing in poisition with new multifunction valve(NRV) ISI marked made of cast copper alloy screwed both ends internally suitable for iron pipe of size 15mm ; Complete all as specified and as directed by Engineer-in-Charge.
Taking down existing unserviceable safety pressure valve and supply and fixing new safety pressure valve with vent to geyser as per latest ISI specification ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for PVC connection hot water type of size 15mm x 600mm long superior quality for geyser ; Complete all as specified and as directed by Engineer-in-Charge.
Replacement of neoprene seal (bottom ring) for 25/35/50 ltr capacity geyser of superior quality ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for painting the outer surface of geysers of 25/35/50 itrs as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc and refixing the geyser in position including water/electric connection and testing, ; Complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Brazing / welding of inner tank at leaking spots up to five leakage of geyser of capacity 25/35/50 ltrs of any type and make of tank after checking up worn out nuts bolts and washers ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of brass chormium plated angle valve, fancy type of size 15mm dia screwed down for high pressure ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of sheet metal enclosure (industrial type DB) complete in 2P+E configuration with plug and socket complete with one MCB SP C Curve type of capacity 20 Amp 10 KA ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for grouting of Tee bolts 12 mm dia, 6" long with nuts washers etc for fixing of 50/35/25 Itrs capacity geyser including cement work and colour matching on existing wall ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in replacement of 3 pin socket suitable for sheet metal enclosure (industrial type DB) 20A ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in replacement of 3 pin plug suitable for sheet metal enclosure (industrial type DB) 20A ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in replacement of 16 Amp plug top ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Socket 16 Amp multipurpose shutter type fixed on laminated sheet top cover ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing Switch 16 Amp fixed on laminated sheet top cover ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Brass chromium plated fancy type bib tabs of size 15mm dia bore short body, screwed down for GI pipe or for brass ferrule and fixed ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing in replacement MCB B Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA as specified and 16 to 32 Amps ; Complete all as specified and as directed by Engineer-in-Charge.
SOLAR WATER HEATING SYSTEM Disconnecting electrical and water supply connection of solar heating device carefully dismantling solar panel with water tube (copper assembly/ETC tube) rubber gasket; nut bolt; biding aluminum channel and glass carefully and servicing/Descaling/cleanning with acid & water circulation and wire brush and brazing of copper tube checking of leakage if any . After servicing reassemble the same and testing of solar water heater ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of gasket set for ETC tube ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of ETC tube holder without cups ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of solar evacuated tube tubes of solar water heater as per existing suitable for 300/ 500 LPD ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing rotational moulded polythelene water storage tanks (Triple layer) capacity 500 litres(cylindrical vertical with closed top), with and including 20mm dia float valve with brass fittings hoisted, fixed in position and making connection including dismantling of existing unserviceable tank ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of aluminium foil for solar collector ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of rubber grommet (for collector) ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of MS dead flange ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of heat pipe for collector ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of round clamp for hose pipe ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of brass flange ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of Toughened/ tempered glass for solar collector having 4mm thickness transmissivity more than 85 %.as per existing size ; Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for coolant/ Food Grade propylene glycol/ etylene glycol for solar heating system ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of heating element for water heating system 03 KW ISI Marked with rubber gasket of suitable Size ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of thermostate ISI marked suitable for solar heater ; Complete all as specified and as directed by Engineer-in-Charge.
Dismantling the complete assembly of solar hot water tank in replacement of supply and fixing 500 ltrs pre insulated hot water storage tank with stand (inner tank SS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tank ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing GI Pipe size 25mm dia med grade galvanised with all fitting ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing GI Pipe size 20mm dia med grade galvanised with all fitting ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing gate valve gun metal with iron wheel head, screwed both ends for iron pipe and fixed size 25mm dia ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing gate valve gun metal with iron wheel head, screwed both ends for iron pipe and fixed size 20mm dia ; Complete all as specified and as directed by Engineer-in-Charge.
RO SYSTEM Disconnecting electrical connection / water connection of RO System carefully dismantling and change the defective parts and reassembling and testing after changing the defects parts ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement RO membrane in welded housing ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of filter housing ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of SMPS 2.5A 24V DC ADAPTOR with incoming and outgoing wires ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement sediment filter ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement activated carbon filter ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing needle control valve assembly ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing plastic pipe 1/4 " blue ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing plastic pipe 1/4 " white ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing elbow PL0404 for 1/4" pipe ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Solenoid valve 24V DC ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement FRT-800ML ; Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LP & HP switch All as specified and directed by Engineer-in- Charge
Supply and fixing in replacement of Diaphragm Pump 150GPD ; Complete all as specified and as directed by Engineer-in-Charge.
Attending day to day emergency complanits for geysers shock, sparking in geyser wiring , geyser not working etc ; Complete all as specified and as directed by Engineer-in-Charge. Notes for Sl Item No.62 (i) Contractor has to take the complaint at MES power house (E/M) from Concern JE E/M Daily Basis (Except Sunday & holiday). (ii) Contrcator has to attend the complaint within 24 Hrs after recived from JE E/M. (iii) Contrctor has to provide the Mobile no so that massges can be send on the same mobile No. (iv) For non collection of complaits from JE E/M Rs.500/- per day will be charged. (v) For Non attendence of complaints in 24 Hrs Rs.200/- per day per complaint will be charged (vi) Contractor has to return the complaint duly signed from the user with time & date.
Bharat Builder
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .