Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance SHOP NO 55 GROUND FLOOR ROHINI SECTOR 7 NAHARPUR FLOOR HARLAL MARKET NAHARPUR SECTOR 7 DELHI OPP GOYAL GARMENTS VILLAGE TOWN DELHI CITY DELHI | Admitted-Finance |
| 2 | Admitted-Finance PP 32 MAURYA ENCLAVE PITAMPURA CHAITANYA CONSTRUCTION CO PP 32 MAURYA ENCLAVE PITAMPURA DELHI NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Admitted-Finance |
| 3 | Not Admitted-PreQual/Technical | Not Admitted-PreQual/Technical Others-Rejected due to FDR not submitted |
| 4 | Not Admitted-PreQual/Technical 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Not Admitted-PreQual/Technical Others-Rejected due to FDR not submitted |
Tender Value
₹4.6 L
EMD Value
₹9,300
Closing Date
1 Jul 2025, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EX. ENGINEER (E AND M) M-IX
D BLOCK OHT OPP DESU COLONY JANAKPURI NEW DELHI-58
Renovation of various t/wells installed under Palam Constituency AC-37
2025_DJB_274394_17
N.I.T. No.7 (2025-26)/ EE(EnM)M-IX
Open Tender
Civil Works
Works
30 days
OFFICE OF THE EX. ENGINEER (E AND M) M-IX
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB EMD Ac No. 50448339804
₹9,300
11 Jul 2025
24 Jun 2025
1 Jul 2025
24 Jun 2025
1 Jul 2025
24 Jun 2025
Name of t/wells :-1. Sadh Nagar, Near Gurudwara, Gali No.2 2. Vijay Enclave tent wala School 3. Mahavir enclave, Sunil Samadhi 4. Dwarka TW Sec.7 B- Block 1 5. Palam No. 4 Lowering & lifting of sub/sets from bore by taking out double flanged GI pipes, submersible P/Set, Cable, cutting of rusted nuts and boltsetc and replacement of damaged D/F GI pipes, cable, defective pump set etc as per site requirement and lowering of sub P/set, sub cable, GI Pipe etc as required, jointing of cable from sub P/Set along with holding of cable with pipes and jointing of D/F pipes etc with nuts bolts and rubber packing etc. The job includes hiring of all T & P, tripod stand, chain pulley block and other material handling equipments, Safety gadgets as required and consumable material (rubber packing and Nuts bolts) will be arranged by the firm as per site requirement by crane. (SOR 27.1)
S/O PVC insulated PVC sheathed flat submersible cable with plain copper conductor having three core 4 sq mm 415/1100V (each roll 100 mtr) Make :- Havells/Fort Gloster/I CL/ CCI/ ICC/ Universal/Grandlay/Havells/DJB approved+B11:B17
Making/supply of 50mm, 3 mtr long approx double flanged (OD 150mm)GI Pipe,medium conforming to IS:1239(2004)SWS,B Class having 3 No L-Type brackets duly welded on each side of flange. The flanges having four holes and One cut for cable. Make- TATA/Jindal Hisar
Supply and fixing of Hut type electrical feeder pillar/metal board of welded construction of size 1370mm x 760mm x 460mm fabricated with 16 SWG M.S. sheet with horizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the Panel Robust, having double door with 14 SWG S.S hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i/c powder coating, Vermin proof having following items. 1. MCCB 63 Amp, 4 Pole-1 No 2. RCCB/ELCB 63 Amp, 4 Pole with earth fault indicator and positive contact indication protecting a circuit automatically 1 No 3. Fully automatic star delta starter of 10HP. 4. LED Indicating lamps with fitting (a set of 3 lamps) 1 Set. 5. Shunt capacitor of 5 KVAR with three phase isolator 1 No . 6. Motor Protection Assembly having Earth Leakage protection, Phase sequence corrector, Single phasing protection, Over load protection. High voltage-low voltage protection. 1 No 7. Programmable time switch (i.e. RYB Phase & facility to change over from automatic to manual & vice versa) up to 10 H.P.1 No 8. Complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc as required. The panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame. Make:-All the insert used in Panel must be of DJB approved makes and should be ISI marked where make
G.I tail piece 50 mm dia 0.5 mtr. Long with one end threaded & other end flanged having 3 No L-Type brackets duly welded with flange having 4 Nos. hole & cut for cable.
F/S of MS bore cOver suitable for 200mm dia MS Pipe. The bore well be fabricated with MS flat size 50mm width 5mm thickness and MS sheet 18SWG in 2 half pieces ilc suitable clamping arrangement
GI double flanged 90 degree 50 mm dia size bend
HYDROCON ENGINEERS (BID ID -1595056)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .