Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.9 L+₹2.9 L (22.2%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹17.0 L+₹3.9 L (30.2%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹22.9 L+₹9.8 L (75.4%)Rejected-Finance | L4 | Rejected-Finance Not being lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
7 Feb 2022, 12:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer 345001
REPAIR AND MAINT OF INTERNAL WIRING E/M FITTINGS AND FIXTURES AT MD ACCN OTM ACCN UNDER THE JURISDICTION OF GE (A) JAISALMER
2022_MES_500681_1
8159/21-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹50,000
Yes
19 Mar 2022
10 Jan 2022
9 Feb 2022
10 Jan 2022
7 Feb 2022
24 Jan 2022
Amount
Taking down carefully copper/ aluminium point wiring (light, fan socket or power) complete including PVC Casing Capping/conduit, fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc and making good disturbed surface of walls, floors etc to match with existing specification complete all as specified and directed by Engineer-in-charge. Note :- Unserviceable material obtained from taking down shall be issued under Schedule of credit.
Taking down old point wiring from existing concealed conduit including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets etc and making good disturbed surface of walls, floors etc to match with existing specification complete all as specified and directed by Engineer-in-charge. Note :- Unserviceable material obtained from taking down shall be issued under Schedule of credit.
Taking down of old unsv submain wiring of any type any size complete all as specified and directed with casing capping / surface conduit/ existing concealed conduit complete all as specified and directed by Engineer-in-charge. Note :- Unserviceable material obtained from taking down shall be issued under Schedule of credit.
Taking down submain wiring any type any size from existing conduit complete all as specified and directed by Engineer-in-charge. Note :- Unserviceable material obtained from taking down shall be issued under Schedule of credit.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge. Note :- Unserviceable material obtained from taking down shall be issued under Schedule of credit.
Taking down the existing unserviceable MCBs/MCCBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge. Note :- Unserviceable material obtained from taking down shall be issued under Schedule of credit.
Taking down of old unsv tube light fitting /bulkhead/ garden light/ gate light of any description light fitting any type any watt complete all as specified and directed by Engineer-in-charge. Note :- Unserviceable material obtained from taking down shall be issued under Schedule of credit.
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including medium grade, PVC casing caping/conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box of 1.8 mm thick and 60 mm deep (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps.
All as per Item No 8.00 here-in-before but for one bell/buzzer point controlled by one push botton.
All as per Item No 8.00 here-in-before but for one socket out let 3 pin 5 Amps on the same board.
All as per Item No. 8.00 here-in-before but for one socket outlet of 3 pin 5 Amp on independent board.
All as per Item No. 8.00 here-in-before but for one light point controlled by two, 2 way switches.
All as per Item No 8.00 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified.
M&L for point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No.in and existing PVC Concealed conduit of 20 mm bore with accessories in wall floor etc with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-charge for One light or fan point, controlled by one, one way switch 5 Amps.
All as per Item No 14.00 above but for one bell/buzzer point controlled by one push botton.
All as per Item No 14.00 above but for one socket out let 3 pin 5 Amps on the same board.
All as per Item No. 14.00 above but for one socket outlet of 3 pin 5 Amp on independent board.
All as per Item No 14.00 above but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated and 4.0 Sq mm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed by Engineer-in-charge.
S&F in repair of switch piano, flush type, 5 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular switch one way 6A, 1 module complete all as specified and directed by Engineer-in-charge.
S&F in repair of switch piano, flush type, 15 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular switch one way 16A, 1 module complete all as specified and directed by Engineer-in-charge.
S&F in repair of switch piano, flush type, 5 amps, 230 volts, single pole, two way (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F in repair of sockets outlet multipurpose 2 in 1, 5 Amps flush type confirming to IS complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular socket 6A-2/3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S&F in repair of sockets outlet multipurpose 2 in 1 pin, 5 and 15 Amps flush type confirming to IS complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular socket 6A/16A , 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S&F in repair of ceiling rose, PVC of size 65 mm x 18 mm two to three terminals (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F in repair of bell push flush type 5 Amps complete all as specified and directed by Engineer-in-charge.
S&F in repair of stepped type, electronic fan regulator on the existing phenolic laminated sheet etc as required complete all as specified and directed by Engineer-in-charge.
S&F in repair of modular fan regulator, 120W 2 module on the existing sheet etc complete all as specified and directed by Engineer-in-charge.
M&L in repair of lamp holder, PVC/ polycarbonate type with cord grip cap suitable for fittings of any description complete all as specified and directed by Engineer-in-charge.
M&L in repair of lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings of any description complete all as specified and directed by Engineer-in-charge.
S&F in repair of bell AC single pole Ding Dong type 230 volt complete all as specified and directed by Engineer-in-charge.
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.0 Sq mm (FRLS) in and including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 4.0 sqmm cable & One run of 4.0 sqmm cable as earth wire and One run of PVC casing & capping shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.0 Sqmm (FRLS) in existing concealed/Surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 4.0 Sqmm cable & One run of 4.0 Sqmm cable as earth wire shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.0 Sq mm (FRLS) in and including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 6.0 sqmm cable & One run of 6.0 sqmm cable as earth wire and One run of PVC casing & capping shall be paid as one unit length.)
M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.0 Sqmm (FRLS) in existing concealed /surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 6.0 Sqmm cable & One run of 6.0 Sqmm cable as earth wire shall be paid as one unit length.)
S&F for LED tube light fitting 20 Watt 4 Feet in length, IP 20 Protection, wall mounted type, Slim LED Batten with extruded aluminium housing and polycarbonate diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver operating voltage 240 V , 50Hz AC Supply and Operating temperature 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 2000, necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
S&F for LED tube light fitting 10 Watt, 2 Feet or 591 MM in length, IP 20 Protection, wall mounted type, Slim LED Batten with extruded aluminium housing and polycarbonate diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver, IP 20 Protection, Operating voltage 240 V , 50Hz AC Supply and Operating temperature 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 1000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
Supply and fixing of recessed/ceiling mounted down lighter with CRCA housing with high bright LED, ideally suited for low ceiling areas Brilliance 36watt LED, size 2ft x 2ft The product features color tuning from 3000 K to 6500 K, necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed by Engineer-in-charge.
S&F LED light fitting 1X10 W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
S&F LED 15 Watt Square surface mounted LED panel, PDC aluminum housing and high translucent frosted plastic diffuser makes it a robust Luminaire. Efficacy 100lm/w complete all as specified and directed by Engineer-in-charge.
Supply and fixing LED building security light fitting 35 Watt (or above) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed by Engineer-in-charge.
S&F in repair GI pipe bracket light grade of 40 mm dia for building security light, clamps made of FI 40 mm x 6 mm Including nuts, bolts & washers, painting complete all as specified and directed by Engineer-in-charge.
S&F Integral decorative LED bollard with polycarbonate diffuser square shaped with IP 65 protection suitable for 10 watts LED with necessary MS base box made out of MS sheet of 2 mm thick of suitable size abbended in PCC 1:2:4 base, electrical connections with adequate size including removal of old unserviceable one complete all as specified and directed by Engineer-in-charge. Make:Havells Cat part No Havells MOUNTBL10WLED830PSYMTOPMMA (0.6 M) or as equivalent from list of makes.
S&F for LED post top lantern/gate Light 35 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories including removal of old unserviceable complete all as specified and directed by Engineer-in-charge. Make-Havells Cat part No CORALPT35WLED 830PSYMTOPC or as equivalent from list of makes.
S&F for MCCB DB VTPN 4 way 415 V double door IP 43 with provision for FP MCCB/Isolator/RCCB etc as incomer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-charge. (Make-Havells Cat part No. DHDLVDRWGOFO04 or as equivalent from list of makes).
S&F for sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnetic locking system complete all as specified and directed by Engineer-in-charge. (Make-Havells Cat part No. DHDMTHODRW040002 or as equivalent from list of makes).
S&F for sheet metal enclosure MCB SPN DB 8 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed by Engineer-in-charge. (Make-Havells Cat part No. DHDMSHODRW080002 or as equivalent from list of makes).
S&F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 100 Amps with extended terminals complete all as specified and directed by Engineer-in-charge. Note:- Suitable size and frame of MCCB required as per existing DBs at site.
Supply and fixing 415 V 10 KA 'C' curve miniature circuit breaker (MCB) of triple pole and neutral rated capacity TPN 40 To 100 Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of tripple pole rated capacity TP 25 To 63 AMP Amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing miniature circuit breaker (MCB) of single pole and neutral (SPN) 32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
Supply and fixing miniature circuit breaker (MCB) of single pole (SP) 5-32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge.
M/s Shiv Builder and Suppliers
Leelashah Enterprises
SS SODHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .