Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹29.3 L+₹1.3 L (4.77%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹31.2 L+₹3.2 L (11.4%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹31.2 L+₹3.2 L (11.6%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹32.2 L+₹4.2 L (15.0%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹45.1 L
EMD Value
₹90,220
Closing Date
2 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI ARJUN PATRO, IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
MANNING AND OPERATION AT SHEKHAWATI GRID 33/11 KV AND ASSOCIATED AREA OF AGE (U) ELECTRIC SUPPLY NO I UNDER GE(U ELECT SUPPLY DELHI CANTT10
2021_MES_440244_1
GE ELECT/D-20/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹90,220
Yes
21 Jun 2021
5 May 2021
4 Jun 2021
6 May 2021
2 Jun 2021
20 May 2021
60 days
Amount
Maintanance services to be provided for 33/11 KV Shekhawati Grid as per details as under (a) The installation is main receiving sub station and complaint center minimume 02 electrician shall be provided (per shift) around the clock (24 x 7). the electrician shall have adequate knowledge of above maintioned job and GE/Engr-in-charge can reject the proposed electriciangiving reasoned rejection. No claim shall be admissible on account of rejection of person. (b) Details of equipment :- Transformer step down 33/11 KV of capacity 20 MVAincluding marshaling box -2 Nos, Transformer 11/0.433 KV of capacity 100 KVA - 01 No, 33 KV way yard - 01 No, 33 KV SF-6 circuit breaker - 07 Nos, SF-6, 33 KV relay control panel - 07 Nos, VCB 11 KV incoming and outgoing type - 23 Nos, Battery Bank with charger 110 Volts - 01 No, Battery Bank with charger 50 Volts - 01 No, Battery Bank with charger 24 Volts - 01 No, 33 KV Isolators - 22 Nos, 33 KV CTs - 07 Sets, 33 KV PTs - 06 Nos, 11 KV Capacitor bank complete with control panel - 01 set, RTCC panel - 02 Nos, LT Panel - 05 Nos and Capacitor Panel - 02 Nos (c) The following checking, testing, supervision shall be carried out by electrician in respect of equpments mentioned at para (b) above:- (i) Recording of allparameters of system as per indication of all equipments installed in the log sheet as directed by ngr-in-charge round the clock on daily basis. (ii) Maintainance of fault register .(iii) Maintainance of shutdown register (iv) Proper operation of 33 KV/11 KV Breaker (v) Giving of Shouldown by draw out of trolley of breaker. (vi) Proper operation of 33 KV Isolators. (vii) Fixing of burnt out fuse in 11 KV VCB panels.
(viii) Checking of LED indication for breaker ON, OFF, Trip, Spring charge, trip circuit healthy on daily basis. (ix) Checking of annunciatore, hooter, indicators, meters, TNC switch, emergency trip push button, MCB for AC DC isolation,heater, thermostate on daily basis (x) Checking of status of Main protection numerical relay Auxillary protection relays such as trip circuit supervision relay(xi) Attending of all complaint of the shekhawati grid. (xii) Cleaning of dust & foreign particles on and around the panel, loose connection earthing connection in the Grid station. (xiii) Testing of earth resistance of all earthing as directed by Engr-in-charge. (xiv) Checking of DC voltage of system as directed by Engr-in-charge.
Note : (i) The contracotor will ensure suitable repalcement of electrician while on leave/weekly holidays and Wages for the same deemed to be included in the quoted rate. (ii ) The contractor shall ensure that electricians/ operator always be present in each shift. In case of absence of any worker the penalty @ Rs 100.00 per hours per electricians/ operator shall be imposed on the contractor. (iii) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , hard standing , foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform , raincoat, protective clothing such as hand gloves ,helmet, safety belt , first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate. (v) Person employed should be working experience of working on HT and LT Installation. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate.
Worker's wage per person per day per shift (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 1.03 to 1.06 as applicable.
LWC as per existing rules on total of srl no 1.03 to 1.07. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 1.03 to 1.07 are exclusive of GST for calculating of labour cess. Refer Sch 'A'Note No 33 (e) on Page No 17 of Tender Document.
NOTE For Item 1 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC, BONUS and LWC under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.
(d) Contractor is required to quote upto two digits after decimal place or otherwise it will be consdered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) Any variation in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’
Supply and fixing, installation , commissioning & testing in replacement of 33 KV control & relay panel indoor type of size 0.75 Mtr (front side) x 0.6mtr x 2.13 mtr (hight) for incoming feeder 33 KV . The panel should be operated by 50 Volt DC and shall be indoor type , dust and vermin proof , IP - 54 class protection and made not less than 2.0 mm , CRCA MS sheet powder coated finsh over one coat of red oxide primer both side operating type, including internal wiring using 1.1kV FRLS insulated multistrand cable (2.5sqmm for CT/PT and control circuit, numbered and colour coded as per IS-5578/1984 having suitable entry for cable consisting of the following:-
(A) Main, Numerical Protection Relay with LCD displaying mimic bay for ON/OFF control and monitoring of feeder current. Built in disturbance recorder and event logger to monitor the Sequence of Events (SoE) using upto 1000 event codes. The relay shall be communicable on IEC 61850 GOOSE platform, using RJ-45/USB/FO port (i) Over current and earth fault protection with minimum pickup at low set of 5% and 1% respectively (ii) Transient/intermittent earth fault protection (iii) Phase discontinuity protection (iv) Aux. Protections incl. Trip Circuit Supervision, Circuit Breaker Failure protection, master trip etc.
(B) Flush mounted aux. relays for: (i) Trip Circuit Supervision. (ii) Master Trip. (iii) Fuse fail (PT) supervision operated. (iv) DC supervision scheme. (v) Local remote switch.
(C) Metering (i) Metering Equipment incl. 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), 01 x Tri-Vector-Meter (Acc.Cl.0.5). (ii) 01no. Multi-Function-Meter (Acc.Cl.0.5) shall be provided with LCD display for measuring current, voltage, power, power-factor and energy-parameters, Total Harmonic Distortion and Max. Demand Indication, same shall be communicable on ModBus via RS485 port.
(D) Indicating Lamp (i) Isolator Open/Close. (ii) DC fail Indicator. (iii) CB auto trip. (iv) CB OFF. (v) CB ON. (vi) CB Spring Charge. (vii) Trip circuit healthy. (Viii) R-Y-B phase LED indication. (ix) Bus Isolator ON/OFF. (x) Line Isolator ON/OFF.
(E) 01 No shunt trip coil and 02 No of closing coils (50V DC) (F) Semaphore indicator (i) SEMA 1 to SEMA 5 indicator clustred LED with glowing lamp. (G) Push button switch (i) DC accept. (ii) DC fail test. (iii) Trip circuit helthy check. (iv) Announciator accept. (v) Announciator reset. (vi) Lamp test. (vii) Haeter switch with thermostat.
(K) Soft ware for relay with life time licence & data cable. (L) The cost of construction of foundation as per manufacturer design, including foundation frame (supplied by OEM) for control pannel, connected control wiring as required at site are deemed to be included in the quoted rate. Note : The above quoted rate quoted by the contrcator should be included for:- (i) Taking down the old unsv panel, T & P, necessary foundation with MS work as required at site/ directed by Engr In Charge, controll wiring with as existing . (ii) The New Panel should be installed in between the old Panel, Make-Tricolite.
Supply and fixing in replacement battery bank comprising 110 volts, 100 AH @ 2 Volt each- 55 Nos sealed maintenance free battery.
Supply only CRC liquid solution for electrical use, pressure packed in bottle.
Supply only Waste Cotton for cleaning of electrical equipments
M&L for re-painting and Preparation of old painted surfaces of steel tubular LT poles 9 Mtr long including cross arms, MS streep, nuts, bolts, washers, cable protection pipe wherever provided etc and painting of complete area of poles with one coat of aluminium paint including rubbing with wire prush/emery paper from 2.1 mtr above ground level to top of pole and cross arms and painting of bottom area of pole upto 2.1 mtr from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed.
Supply & fixing in replacement KIOSK Box weather proof made up of one piece mounted on SMC base and door pole mounted hinged door of size 333 x233x 120 mm outside and 300 x 200 x105 mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 6 Amp fuse grip with base for controlling the steet light fitting and FL clamps 30x4mm with necessary MS nuts bolts and washers and including applying two coasts of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface and including embassing/painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as directed.
Supplying, installation, commissioning and testing in replacement of PT unit three phase, three limbs, upto 11 KV draw-out type, resin cast dry type, single ratio having primary voltage 11 KV & secondary voltage 110 volts, 50 VA class-1 including necessary bus bar connections & wiring for metering complete all as specified and directed .
Supplying , installation, testing and commissioning of 11 KV, 630 Amps having short circuit capacity 21 kA/3-sec, Outdoor (IP54), RMU (Ring main unit) comprising of 01 Nos motorized operated Load Break Switch and 03 Nos 630 Amp Fixed-Type motorized spring-charging VCB electrolytic grade copper busbars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank with min. thickness 3+0.5 mm, IP 67 Degree of Protection , internal-arc classified 20kA/1sec, on-site-repairable with site replacable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have padlockable double-door access with anti-theft higes, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit alongwith Bus-connected, fixed-type Auxiliary transformer shall include the following along with all necessary accessories and fittings as required at site.
(A) 01 Nos. Incoming Load Break Switch module each consisting of following accessories :- (i) Each switching-unit is designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 21 kA/3-sec, Making Capacity - 50kAp -01 No (iii) Auxiliary contacts - 1NO + 1NC-01 No (iv) Spring-assisted snap-action motorized mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch -01 No
(v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 185 Sqmm , 3 Core , XLPE AL cable termination in live-condition. Each Set of 03 (vi) Right angle boots (push on type)-Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom , front with Interlocking mechanism including earth switch -01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It is to be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault-01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No
(B) 03 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch.The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 21kA/3-sec, Making Capacity - 50kAp-01 No (iii) Aux. contacts - 1NO+1NC-01 No (iv) Stored-energy motorized high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow handle-less and un-inhibited operation -01 No
(v) Cable terminals (site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 185 Sqmm , 3 Core, XLPE AL cable termination in live-condition. Each Set of 3 (vi) Right angle boots (push on type)-Each set of 3 (vii) 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol-01 No
(viii) Associated ring-core cast-resin insulated CTs 50/1 Amp , 2.5 VA, 10P10 for protection ( Set of 3) for 02 Nos outgoing and CTs 150/1 Amp , 2.5 VA, 10P10 for protection ( Set of 3) for 01 No outgoing. (ix) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (x) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (xi) Push button for breaker trip (xii) Shunt trip coil 24V DC - 01 (xiii) ON, OFF, TRIP mechanical indication on the front mimic of the panel - 01. (xiv) Emergency Trip Push Button - 01.
(C) 01 No. Bus-connected, fixed-type Auxiliary transformer to provide required aux. supply and metering consisting of following accessories :- (i) 1-Ph (11kV/rt3):230VAC, 500VA Auxiliary transformer-01 No (ii) 2x12 Volt DC battery-01 Set (iii) Battery charger-01 No (iv) HRC fuse-links for primary side isolation and AC/DC MCBs for secondary isolation-01 Set (v) Voltmeter & RYB LED Indications to confirm AC/DC supply availability-01 Set (vi) Anti-condensation space-heater-01 No (vii) CFL lamp for illumination and 3-pin socket with switch -01 No
(D) Additional equipment deliverd separately or mounted seperately :- (i) Operationg Handle for Manual Isolator/Disconnector/Earthing Operation-02 Nos (ii) Standard Manometer -01 No (iii) Operation and Maintenance Manual -01 No (iv) Installation & Commissioning Manual -01 No (v) Cable clamping provision (standard) -01No
Note:- (i) It is preferable to have all feeder-switches inside single stainless steel compartment with incomer feeders at the extremities to prevent chances of failure due to plug-in coupling arrangement. (ii) Necessay interclocking arrangement shall be provided for safety and operations (iii) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. Any claims towards internal arc compliance, number of mechanical/electrical/short-circuit operations, gas-leakage rates etc. shall not be accepted unless proven via type-test reports of model being offered. (iv) Cost of provn of plinth for RMU as per OEM drawing and HT 11 KV indoor jointing kits for incoming/ outgoing cables are deemed to be included in the cost.
Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 3.5 m below normal ground level) with top edge of earth plate not less than 2.5m below normal ground level, connected to galvanized iron strip 32X6 mm by means of electric arc welding of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other side complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe light grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI earthing and protection pipe upto 7.5 meter beyond the earth plates electrode.
Note : (i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
INDIAN CONSTRUCTION CO.
mayur enterprises
Buddham Builders
IK ONKAR ENGINEER AND CONTRACTOR
MV Engineers And Contractors
Vijay Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .