| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC | ₹2.4 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹2.8 Cr+₹46.1 L (19.4%)Rejected-Finance T 3 PARMESHWARI BLDG CHATRIBARI RD GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹2.8 Cr+₹46.1 L (19.4%) | L2 | Rejected-Finance Ref to Fin Minutes |
| 3 | L3₹2.7 Cr+₹34.0 L (14.3%)Rejected-Finance | ₹2.7 Cr+₹34.0 L (14.3%) | L3 | Rejected-Finance Ref to Fin Minutes |
| 4 | Rejected-Technical | - | - | Rejected-Technical Ref to Tech Minutes |
Tender Value
₹2.7 Cr
EMD Value
₹5.5 L
Closing Date
7 Nov 2019, 2:00 pmClosed
EE IND
Bamunimaidam Ghy 21
Construction of Office building (G plus 2) for DICC Kamrup (M)
2019_ICD_14488_1
EEG/545/2010/388 date 22/10/2019
Open Tender
Civil Works - Building
Item Rate
540 days
Bamunimaidam Ghy
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,200
EE ICD
₹5.5 L
Yes
18 Dec 2020
24 Oct 2019
7 Nov 2019
24 Oct 2019
7 Nov 2019
30 Oct 2019
24 Oct 2019 - 7 Nov 2019
Amount
PILING WORKS MACHINE DRIVEN PILES - Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1) (A) UNIFORM PILE (I) Concret garade M20 (iii) Pile dia 400 mm
Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement (iii) 400 mm dia
Empty boring for specified diameter piles from ground level to cut-off level. d) Pile Dia 400 mm
Supplying, fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning, cutting and bending to proper shapes and length as per specifications and drawings. The rings should be welded with vertical reinforcements as per specified IS codes of practice. (Inclusive of lap length, hook, chair, bend, anchor...etc) (A) TMT bar made of Primary producer (From Primary producer) (C) ISI approved M.S. Rod
CIVIL - Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (b) In prop 1cement: 3 sand :6 coarse aggregate by volume
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. a) 100mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. P) Using admixture, plasticiser etc b) M20 grade concrete or Prop. 1:1.5:3
Extra for using plasticiser in concrete if admixture, plasticiser etc are not included in the item rate b) M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work (a) Using 25mm thick plank
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (a) In Sub-structure upto plinth level including dewatering if necessary 1:4 in proportion
(b) In superstructure above plinth level up to 1st floor level.
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level.
Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). Executive range Somany/ Orient/Nitco/Asian Make Of size 300mmx300mm and above
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). b) Executive range Somany/ Orient/Nitco/Asian Make i) Of size 200mmx300mm and above
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Marbonite/ Make ii) Of size 600mmx600mm and above
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
B) On fair side Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed. i) 10 mm thick plaster b) In cement mortar 1:4
Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. a) On Single coat plaster
b) On two coat plaster
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. a) On Single coat plaster
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.) Rincs cool top roofing sheet as directed by the Departement (iv) 0.60 mm thick
Providing wood work in in frame (chowkaths of doors, windows etcand other simlllar works fixed in position.with cc or brick masonary…………………………………………... etc (a) With sal wood
Providing fitting and fixing stainless steel (grade- 304)railling made of hollow tube, plate etc. including welding, grinding , polishing,…………… complete.
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) A) With Teak wood / Sissu wood. (i) 40 mm thick.
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. a) Decorative type face panel and block board core. (iii) 30 mm thick .
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I . Plain grill (c) Fixed to Brickwork/P.C.C/R.C.C.
Providing , fabrication and fixing of structural glazing made out of coloured Anodised aluminium mother frame 6 nos 1.2m each @ 1.819 Kg/m and subframe of 16 nos 0.60 m each @ 0.31 Kg/m of Jindal or equivalent and 5 mm reflective glass of approved shade. The glass to be pasted using structural selicon (DC 995) and weatherseal silicon to be used (DC 789), the structure complete with all accessories as and where necessary.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a)2 Track sliding window (iii)5mm coloured glass
(b)5 Track sliding window (iii)6mm coloured glass
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (i) 6mm clear glass
Providing two coats of acrylic water based wall putty/ wall filler of Nerolac over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture ( Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture ( Nerolac)
Extra over item no 13.4.1 above for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture ( Nerolac). (i).Acrylic Emulsion Paint approved brand and manufacture ( Nerolac)
Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). (i).Surfaces over 100mm in width or girth.
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door bolts i) 300mm x 16mm
b) Tower bolts i) 300mm x 12mm
c) Door handles i) 75mm
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
FIRE-FIGHTING WORKS- FIRE EXTINGUISHER Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG)
SANITARY - INDIAN TYPE WATER CLOSET - Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm a) White i) Parryware make
EUROPEAN TYPE WATER CLOSET - Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make a) White (i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover)
PVC FLUSHING CISTERN - Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make a) White (vi) Slimline Standard (Cat No.C8297)
CONCEALED CISTERN - Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (C) Jaquar Make Concealed Cistern (Cat.No.CIB-WHT-31801011X) with Control Plate (CP) (Cat. No. CIS-CHR-31191510X)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. A) Parryware make a) White (ii) Aquaseal (Cat. No.C0508)
SQUATING PLATE URINAL - Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware Make (i) White (Cat. No. C0503)
WASH BASIN - Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) (C) Jaquar Make (a) White (iv) Cascade NXT 550 x 440 with long Pedestal (Cat. No.C0404/C0380)
MIRROR - Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (b) Size 600mm x 450mm
SHELF - Corner glass shelf with bracketsof Jaquar Make (a) Jaquar Make Continental (Cat.No.ACN-1173)
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER - Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (a) Parryware Make (i) Recess SP & SG dish (Cat.No. C9935)
TOWEL RAIL,TOWEL RACK & TOWEL RING - Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No. ACN-1101N)
WASTE COUPLING - Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar Make (i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)
BOTTLE TRAP - Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)
Supplying, fitting and fixing I.S.I marked or similar approved H.C.I pipe including bolts and nuts and other fittings as required and complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. 110mm
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee with door of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mm dia.
GRATING - C.P. Grating (ii) 110mm dia
MANHOLE COVER - Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 38 Kg. weight complete as directed and specified
SOAK PIT AND INSPECTION CHAMBER - Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
PPR PIPE - Supplying fitting and fixing SFMC (SAVOIR-FAIRE MANUFACTURING CO. PVT.LTD.) brand 3 layered (outer green coloured,UV Stabilised,middle black coloured and inner white coloured (with antimicrobial property) fusion welded P.P.R (Polypropelene Random Co-Polymer) pipes of following size with all necessary fitting such as bend ,tee, elbow,reducer,plug and clamp etc. complete at all levels as directed and specified. (i) In exposed surface or trenches (a) 16 mm OD (PN-16) SFMC brand 3 layer P.P.R. pipe
(b) 20 mm OD (PN-16) SFMC brand 3 layer P.P.R. pipe
(e) 40 mm OD (PN-16) SFMC brand 3 layer P.P.R. pipe
SEPTIC TANK - Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. 100 Users
INTERNAL WATER SUPPLY WORKS - PIPING - Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (A) Exposed on walls b) 40 mm dia (Medium) i) Using Tata make
e) 20mm dia (Medium) i) Using Tata make
f) 15 mm dia (Medium) i) Using Tata make
BIB COCK - Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Essco make (a) Bib cock short body(Delux/Sumthing spl./Tropical)
Jaquare make (a)Continental /Clarion (iii)2-Way bib cock
Supplying fitting and fixing polymer bib cock (15mm dia) of Polymer Prayag make directed and specified.(G.I. & C.P pipes will be measured separately) (a) Standard
STOP COCK - Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar (a) Continental / Clarion (ii) 15mm dia( Angular stop cock with long thread )
PUSH BIB COCK - Supplying fitting and fixing push bib cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately). a) C.P.C.H. (a) Light type
PILLAR COCK - Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaguar make (a) Continental
Elbow action pillar cock (Agmeco) (a) MS-481/ Regular
SINK COCK - Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) Sona brand a) Sink cock upper/ lower spout 15mm
SHOWER - Supplying fitting and fixing overhead adjustable Chrome Plated (C.P.) spray shower 15mm dia. of Sona make with wall flange as directed and specified.(pipes will be measured and paid separately) (a) Supreme shower with arm
VALVE - Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 40 mm dia.
d) 2O mm dia.
e) 15 mm dia.
EXTERNAL WATER SUPPLY WORKS - Piping - Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed A) G.I. pipe with GI fittings a) TATA / SAIL (Medium) i) 15mm diameter
ii)20mm diameter
v) 40 mm diameter
vi) 50mm diameter
Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fitting complete as directed by the department ii) Bore hole of 150mm diameter
Supplying, fitting and fixing pipes plain/ bevel ended for causing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign material in the annular space between the borehole and assembly pipes complete as directed by the Department , PVC Pipe (a) Supreme Brand (v) 110mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. A) G.I. Pipe (a) TATA/SAIL ( medium) sockets should be welded to the pipes. (iii)40mm diameter
FILTER - Supplying, fitting and fixing of ISI approved PVC filter 3.00 metre long
WATER TANK - Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes 1500 Lt capacity (a) Sintex make
Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. (a) 1500 litre capacity
IRON REMOVAL WATER FILTER - Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of DOLPHIN make with all necessary fittings such as valve,bib cock,pipe connection etc.with a free maintanance period of six monthhs. (III) 5000 liters capacity. (a) 6 mm thick Vessel FRP
Single phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 1.5 HP STAGE 5 to 26 with control panel.
INTERNAL ELECTRIFICATION Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
B. SWITCH/SOCKET/PLATE ETC. Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 3 module
6 module
12 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department. 3 module
6 module
12 module
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES. Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying with fitting fixing of T 5 luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection cable, as approved by the Deptt.)with 1.5 sq mm P.V.C. insulated S.C.copper conductor as required and as directed by the department. BATTEN LIGHT, ADRENO V 28 W TWG 207 with 1x28 W T-5 Fluorescent tube. (Philips make or equivalent)
Supplying with fitting and fixing of electronic chime MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
D. EARTHING Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx6 mm heavy duty copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
E.CEILING/EXHAUST FAN Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Power Flow 225 mm sweep (ORIENT make)
F.AC WORK Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable, as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department. 2 Ton capacity. Daikin make
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make) 5.0 KVA Automatic Input 90-280 V Out put 200-240 V
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt. Overload Relay Range 16 - 25 Amps in 3 Module
G. MCB/MCBDB/RCCB ETC. Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4way TPN (4+12) double door
6way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 6-32A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 30mA sensitivity DP RCCB 40A (ABB, Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 80A
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 3P MCCB (ABB(S6) , Schneider, legrand, Siemens, L&T D-shine make) 315A
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider, legrand, L&T make) 250A
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 & 1/2 A2XWY A2XFY 120.00 Sq.mm 3&1/2 Core U.G. cable in 65mm dia medium duty G.I. pipe
70.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe
50.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe
35.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe
Cost of meter with meter testing and supervision charge etc.
Load security for 80 KW of load.
Laying of Foundation stone and Inaguration ceremony (Estimated cost Rs. 350000.00 for 2 job)
T N T Projects Ltd
Harekrishna Talukdar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .