| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC | L1 | Accepted-AOC The Lowest tenderer. | |
| 2 | L2₹45.2 L+₹3.4 L (8.25%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹45.5 L+₹3.8 L (9.00%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹46.3 L+₹4.6 L (10.9%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹48.4 L+₹6.6 L (15.9%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
8 Jun 2024, 6:00 pmClosed
Commander Works Engineer Hisar
Headquarters Commander Works Engineer Military Engineer Services Hisar, Military Station Hisar Hisar (Haryana)-125006
SPECIAL REPAIR AND REPLACEMENT OF TRANSFORMER AND CONNECTED ITEMS AGAINST BER TRANSFORMER AT ASCON NODE CHANNIBARI AND MARRIED ACCN OF EBS UNDER HMS UNDER GE (WEST) HISAR
2024_MES_652754_1
CA NO CWE/HSR/14 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Hisar
As per Notice Inviting Tender (NIT)
7 documents required · 7 mandatory
₹500
Yes
GE (West) Hisar
₹1 L
Yes
2 Sept 2024
7 May 2024
10 Jun 2024
7 May 2024
8 Jun 2024
25 May 2024
7 May 2024 - 28 May 2024
Amount
Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 100 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +2.5% to -5% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, automatic voltage stabilizer of capacity 63 kVA, three phase, IP55 protection, copper wound, oil cooled type with minimum 250 litre of oil, designed for input voltage of 340 V to 480 V and output voltage of 415 V ± 1% (Phase to phase), 240±1% (Phase to neutral), voltage correction rate of 15 V per second, suitable for unbalance input voltage, unbalance load, metallic body with lifting hook duly power coated, LCD display for Input, Output, Low and High Voltage, Time Delay, Mains ON, Low and High Voltage Cut-off, with under and over voltage protection, short circuit protection, surge protection complete all as specified and as directed.
Dismantling existing LT feeder pillar box/ LT panel board of any type and size including recovering serviceable items including making good disturbed surfaces complete all as specified and as directed.
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated copper bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 200 Amps rated copper busbar fully insulated with class F materials and nuts, bolts, washers for connection: - 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming/ Outgoing: (a) MCCB rated current (In): 125A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and fixed magnetic setting, four pole, for 415 V, 50 Hz AC supply: - 1 No (b) MCCB rated current (In): 63A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and fixed magnetic setting, four pole, for 415 V, 50 Hz AC supply: - 2 Nos (c) LED indicating lamps (Red, Yellow, Blue) – 1 Set (D) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Disconnecting all existing connection with transfomer and taking down and shifting transformer from any substation under the GE to AGE E/M store yard with help of Hydra (Recovery)/JCB/ Crane etc. complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
M & L for moorum/red bajri filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for cement concrete M10 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate 150 mm thick in sub base for laying tiles, pavings etc. complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 75 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
Material and labour for plastering 20 mm thick (in two coats of 15 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 250 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 200 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +2.5% to -5% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 160 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +2.5% to -5% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
Supply only galvanized steel chain link fence fabric of mesh size 100 mm X 100 mm, made out of 3.15 nominal dia mesh wire, heavy zinc coating type conforming to IS 2721: 2003 complete all as specified and as directed.
Supply only galvanized steel line wire made out of 4.0 mm nominal dia wire, heavy zinc coating type conforming to IS 2721: 2003 complete all as specified and as directed.
Fixing only galvanized steel chain link fence fencing including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc. including provn of binding wire complete all as specified and as directed.
S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed.
Raman Electric Trading Co
PRADEEP TIWARI CONTRACTOR
SAINI ELECTRIC STORE
malik constructions
MONA GENERATOR SEVICES PVT. LTD.
Vardhman Airport Solutions Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .