Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | ₹24.0 L | L1 | Accepted-AOC ok |
| 2 | Rejected-Technical | - | - | Rejected-Technical Reject |
| 3 | Rejected-Technical | - | - | Rejected-Technical Reject |
Tender Value
₹23.1 L
EMD Value
₹46,000
Closing Date
16 Feb 2026, 5:00 pmClosed
Er. Jaspreet Singh Vermi
Executive Engineer Provincial Division Gurdaspur
Construction of Ayushman Arogya Kendera AAKS AAM Aadmi Clinic AACS in Central Jail Gurdaspur
2026_CEPW_159495_1
Bid No. 07 Dated 05-02-2026 Jail
Open Tender
Civil Works - Buildings
90 days
Gurdaspur
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹46,000
Yes
20 Mar 2026
6 Feb 2026
17 Feb 2026
6 Feb 2026
16 Feb 2026
6 Feb 2026
Providing Vitrified tile & Entrance flooring after Dismantling of Existing Flooring
Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.
Dismantling glazed tiles (to be carefully removed).
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size 600x600 mm.
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-inCharge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
Cement concrete 1:6:12 mixing by mechanical means using concrete mixer volumetric type (With stone aggregate 40mm gauge)
First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Centering and shuttering for columns (circular or curved in plain)
Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels
12.5 mm thick cement plaster 1:4
Partition, Ceiling & Painting Work
Dismantling brick work tile, masonry or tile lining In cement
Supply & Fixing of pressed steel frames (Chowkats) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section(standard design latest) including iron lugs (hold fasts) iron hinges, confirming to P.W.D. specifications including bolts for fixing stops, lock-notch provision for receiving tower bolts, Hydraulic spring and finished with one priming coat of approved quality, fixed in position, including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete.
Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg/rmt
Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. A) 35mm thick panelled, glazed or glazed and panelled.
Factory manufactured solid flush door fixed in position iron hinges, etc . (excluding the cost of any fittings other than specified above but including the labour for fxing the same in position a) comercial with elm or gujan facing on both/sides with laminated core and lipped edges. iv) 35mm thick.
Providing and fixing high pressure laminated sheet 1 mm thick.
Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect Glazing area above 0.09 sqm
5.0mm thick Plate glass (INDIAN)
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm)
Providing and fixing mineral fibre false ceiling tiles at all heights upto 4 Mtrof size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm
Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge.
Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash-welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items)
Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect
Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm thick above 0.40 sqm area.
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminum doors including necessary cutting and making good etc. complete.
Providing and fixing beading to door and windows chowkats of commercial hard wood, such as Hollock, Champ, Chirassy Chaplash etc (Non coniferous timber other than teak conforming to ISI specification no 100., kiln seasoned) with iron screws, fixed in position complete as per design and shape required 50mmx12mm
Scraping White wash and colour wash
Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Providing Signage & Providing New Colour ACP Sheet after Removing of existing ACP Sheets
Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. 3mm thick ACP Sheet
Writing matter on front signage Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012
Providing and Fixing Name Plates of various sizes made of PVC sheet printed with self adhesive tape pasted on sunboard complete as desired by Engineer-in-Charge
Providing and Fixing AAC/AAK Logo
Repair of Existing damages i.e regrading of tile terracing, replacement of glazing, replacement of chequred tile on ramp, replacement of parking pavers.
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. IS COde : 15658 (2006)
Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.
Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded).
Cost of new tile to be replaced instead of broken tiles in regrading of tile terracing including loading / unloading & all leads as desired by Engineer in charge .
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing in position gratings 150mm x 150mm on top Khura PVC grating
Dismantling Reinforced cement concrete
Supplying and fixing of GI sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. c) Doors and windows frame of size 151mm x60mm with 35 mm wide double rebate weighing 3.95 kg per meter
Providing and fixing of 25mm thick PVC flush door shutters (without chowkhat) upto 737mm width of colour and shade as approved by Engineer-in-charge made out of a one piece Multi chamber extruded PVC Plug section of the size of 762mm X 25mm or less as per requirement with an average wall thickness of 1mm ± 0.3mm. PVC Plug foam end cap of size 23x10mm are provided on both vertical edges to ensure the overall thickness of 25mm. An MS tube having dimensions 19mm x 19mm is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane Code Description Unit Quantity Rate Amount foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25mm X 11mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufactures’ specification and drawing to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places
Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : iv) Udaipur Green Marble Tiles of thickness 18mm to 20mm b) Slabs sizes above 0.50 sqm
Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure
Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
BRANDING
Wall Paint
6 Logos with Vinyl printing with 5mm thick sunboard
Borders on Door & Windows with vinyl printing with 5mm thick sunboard
Name board with Vinyl printing with 5mm thick sunbaord
Installation of branding with Vinyl Printing with 5mm thick sunboard
PUBLIC HEALTH
Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect.
Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete.
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. iii) Size 630 mm x 450 mm x 830 mm
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 75mm o/d (viii) P Trap/Floor Trap 75mm x 75m
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 75mm o/d (viii) P Trap/Floor Trap 75mm x 75m
110mm o/d single socket SWR UPVC pipe lines laid complete
75mm o/d single socket SWR UPVC pipe lines laid complete
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
C.P. brass Bib cock long nose/ long body foam flow without flange
Brass Bib cock/Stop cock 15mm x 400gm
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut
Providing and fixing jet spray with 2'-6" long PVC pipe.
With C.P. Brass nut
Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
Sink with drain board overall size 1070x464mm bowl size 430x355x200mm and waste coupling
Providing and laying, jointing, fixing and testing ISI Marked UPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. A) UPVC Pipe 10 Kgf/cm2
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 600mmx450mm
Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect
C.P. brass towel Rails size 15mm dia 610mm long
C.P brass towel ring
Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -incharge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.
Plateform for Water Storage Tank
First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
Reinforced cement concrete M-20 mechanicaly using computerized concrete batch mixing plant including carriage by transit mixer with in 1km lead, pumping by motorised pump and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete (Make:- SAIL/TATA/RINL)
12.5mm thick cement plaster 1:4.
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
P/F Refrigrator 165 Ltr complete in all respects
P/F Split AC 2 Tonne
P/F Split AC 1.50 Tonne
P/F Split AC 1 Tonne
Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer
Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
AUTOMATIC VOLTAGE STABLIZER Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- (i) Automatic Voltage Stablizer 2 KVA
ELECTRICAL
RECESSED AIR CONDITION SUPPLY TERMINAL POINTS:
Wiring air condition supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:-
Wiring AC supply terminal points having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
RECESSED COMPUTER SUPPLY TERMINAL POINTS:
Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- Accessories
Wiring Computer terminal points having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indiicator and 2No. blanking plate (Modular accessories).
RECESSED MODULAR TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS:
Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases:- Accessories
Wiring Telephone socket point RJ11 (one module)
Wiring Networking socket point RJ45 (one module)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-
Wiring fan point (With fan box)
Wiring light point
Wiring call-bell point
Wiring 6Amp. wall socket point
Wiring 6Amp. Plug control comprising wall socket point
Wiring 16/20Amp. power plug control point
PVC INSULATED FR COPPER CONDUCTOR CABLES:
Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge
Overall size 1.5sq.mm (Un-sheathed)( Earthing & Invertor )
Overall size 2.5sq.mm (Un-sheathed)( Power Point & Computer Points)
Overall size 4sq.mm (Un-sheathed)( For A.C )
Overall size 10sq.mm (Un-sheathed)( For LT Panel to VD4 Light Load & TPN 4 Way Light)
Overall size 16sq.mm (Un-sheathed) (For LT Panel to VD4 Power Load & TPN 4 Way Power)
PVC, HDPE PIPES & PVC FLEXIBLE PIPES:
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, MS saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed)
Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed)
COPPER EARTHING:
8 SWG COPPER EARTHING :
Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A- Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation:-
Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long
Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
BONDING TO EARTH WITH COPPER WIRE:
Bonding to existing earth with copper wire in heavy gauge (1.6mm thick) welded conduit pipe with bends, junction boxes, steel hooks and MS saddle clamps including painting etc:-
Bonding with copper wire 8S.W.G. (4mm dia) in HGW conduit pipe 20mm dia. (on surface)
SUPPLY AND ERECTION OF WIRING ACCESSORIES:
Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc:-
Call Bell 220/230 volts AC Ding Dong
3 Pin Plug Top 25Amp. (ISI marked)
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:
Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
MCB Double Pole 50, 63amp. (10kA, Curve-C)
MCB Triple Pole 50, 63amp. (10kA, Curve-C)
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:
Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
SP&N Double Door Distribution Board 12 way each( 1 for Light & 2nd for Power )
XLPE INSULATED UN-ARMOURED CABLES (LOOSE):
Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications
Overall size 16sq.mm (4Core) Un-armoured (Loose)
SHEET METAL IRON CLAD SWITCHES:
Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:-
ICDP Switch 32amp., 415volts
SINGLE ARM BRACKETS FOR GI PIPE POLE:
Supply and erection of G.I. Pipe 40mm dia. (A- class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105º, the bracket should be fixed on the top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect as approved by the Engineer-in-charge at site:-
Single Arm Bracket 1 metre Long with GI Reducer 80mm x 40mm
MCCB'S (MOULDED CASE CIRCUIT BREAKER):
Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (Conforms to IEC:60947-2) having Ics=100%, Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of thimbles etc:-
MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 63/51mm (Outer/ Inner dia.)
Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. is the lighting fixture manufacturer should have inhouse NABL accredited lab.
Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.
Supply and erection of BEE 3 star rating AC Ceiling Fan 1200mm (48") Suitable for 230 V single phase with double ball bearing copper wound full aluminium body ,3 no.s blades white in colour .The mounting type is down rod mount .The product should possess a minimum air deleveryof 210 CMM .The rated speed of the product must be minimum of 300 revolution per minute and 5 no.s of speeds .the approximate weight of the product should be 4kg and 189gms without packing or higher .the product should have a manufacturer`s guarantee / warranty of minimum 2 years .the product should be complete in all respects with fan motor blade set doen rod canopy set. shackle kit .twisted wire etc. incluyding erecection & testing of ceiling fans having connection With PVC insulated PVC sheathed two single core copper conductor ( FR ) cable 0.75 sqmm complete in all respects as per satisfaction of the engineer-in charge at site
Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
Supply and erection of LED Street Light 45 watt (including LED driver) with pressure die cast aluminium housing with control gear ( IP 66 protection),THD< 10%, CRI minimum 70, High power LED with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, efficacy of LED fixture minimum 120 lumens per watt, complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to CM Punjab vide letter No. AT-2021/GL 1410-1422 Dated 06/05/2021 Wipro 45W Streetlightskyline SL, Crompton CRP-409-45-57-HL2-GL-NSR, Phillips (Signify) BRP056 LED53 CW SLF PSU S1
Supply and erection of Ventile Air Fan 225/230mm with aluminium louver shutter longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. The fan should conform to Technical Specifications attached.Cromption-Drift Air Anti Dust 9", Havell's-Ventil Air -DSP, Bajaj- Bahar DOM Ex Fan
Supply & Erection of Wall fan of 400mm Sweep (16") High Speed, Make Havell's Model NO: DZIRE,/ Make: Orient Model No: 400mm Wall 80 Wind Pro/ Make:. Crompton Model No:WM Wind Flow(Hi Speed) / Bajaj Model Non Spectrum Grey Wall Fan including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connection as per approved /desired by the engineer in charge of work at site
Supply Installation Testing and Commissioning of 10 port 10/100 PoE switch, 8*10/100 PoE port + 2 10/100 uplink, power budget 120W, IEEE 802.3af/at extended range 250 mtr complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, installation, testing & commissioning of Category 6 UTP , 4 Pair This cable well exceeds the requirements of TIA/EIA-568-C.2 and IEC/ISO 11801. Construction: 4 twisted pairs separated by cross separator, 4 channel, polymer spine / full separator. Half shall not be accepted. Cable should be Armoured. Operates at bandwidth of 250 MHz, Conductor Solid Bare Electronic Grade Copper. Inner jacket should be PVC and outer should be PE, suitable for direct burial. Insulation: Polyethylene, Attenuation (< 36 db/100m), Pair – to – pair and PS NEXT, ELFEXT and PSELFEXT, Return Loss, ACR and PS ACR., Nominal Outer Diameter of Cable should be 9.70 mm and Conductor Diameter 0.56 mm (23 AWG), Cable should support operating Temperature from -20° to +60°C, Cable should come with printed sequential Length Counter on each meter, Cable support Conductor Resistance 93.5 OHMS/1000MTR@20 Degree, Mutual Capacitance of cable should be < 5.6nF/100m, Max Resistance Unbalance of cable should be 5% Max, Capacitance Unbalance of cable should max 330pF/100m, Cable support Delay Skew: < 45nS, Operating Voltage: 72V and NVP: 69%, Shall Supports Gigabit Ethernet (1000 base-T) standard and Operates at bandwidth of 250MHz complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
Supply, installation, testing & commissioning of 1 KVA UPS with Input power factor - 0.99, Output power factor - 0.8, OVCD inbuilt , DC V 36v, Efficiency : Above 90%. .complete in all respects as approved and desired by the Engineer-in-charge at site
S/I/T/C of intercom facility 1+1 Basic Plan Phone Ringer volume control switch Tone/ Pulse Switchable Redial Mute Flash Pause Intercom facility Call T, Holding the line / Music on Hold during call transfer Line use LED Indication, Secrecy during conversation between both phones, including connecting cables complete in all respect as approved and desired by the Engineer in-charges at site
S/I/T/C of Token Calling Display System having screen size 4 inches, Voice calling/ Bell System, complete key pad Etc, calling display up to 60 meter cable (5 meter length included), serial communication design, Text Color Red Display Shape Rectangle,Power 5 W,Sound Type Mono Display Technology 7 Segment Voltage 220-240 V AC Suitable for Clinic, Hospital,Cash counter etc, Warranty 1 Year,220 VAC Operating Voltage Character Capacity 3 Character, Power Consumption,Rectangular Metal body ,complete in all respect as approved and desired by the Engineer in-charges at site
Supply and erection of Wall Mounted 6U Rack with power point and fan. complete in all respect as approved and desired by the Engineer in-charges at site
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
Supply ,erection,testing & commissioning of Invertor 2 KVA ,200 amp Battery ( 2 no. ) connections and testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
BOQ_323441.xls
BOQ • 0.39 MB
AACS.pdf
Tender Documents • 2.59 MB
Download all tender documents and submit your bid