Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹36.9 L+₹5.8 L (18.8%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹37.2 L+₹6.1 L (19.6%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹37.2 L+₹6.1 L (19.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹39.7 L+₹8.6 L (27.7%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹40 L
Closing Date
16 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim 737102
Repair maint of external LT electric supply at certain unit under GE Gangtok
2021_MES_468866_2
8962
Open Tender
Miscellaneous Works
Item Rate
182 days
Gangtok
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
Yes
29 Oct 2021
29 Sept 2021
18 Oct 2021
29 Sept 2021
16 Oct 2021
7 Oct 2021
60 days
Amount
Taking out of old Unsv LT cable from any location complete all as specified and directed by Engr in Charge.
Dismantling of old ACSR conductor from the disturbed span including line spacer and unserviceable material removing from site of work to shifting MES store complete all as directed.
Dismantling of old unserviceable/defective (Pin type, Shackle type) insulators of any size/type and removing materials from site of work to shifting MES store complete all as directed
Dismantling of old cross-arms of mild steel channel or angle sections, etc, including mild steel bolts, nuts, washers, etc. and removing from site of work complete all as directed.
Supply and laying light grade GI pipe (ISI Marked) as cable protection to be fixed on wall / pole with necessary clamps as per existing or in road crossing as ordered of size 80 mm complete all as directed. ( Note :- Unit rate quoted is deemed to be inclusive of MS clamps required to be fixed on pole).
Supply and laying light grade GI pipe (ISI Marked) as cable protection to be fixed on wall / pole with necessary clamps as per existing or in road crossing as ordered of size 50 mm complete all as directed. ( Note :- Unit rate quoted is deemed to be inclusive of MS clamps required to be fixed on pole).
Supply and laying light grade GI pipe (ISI Marked) as cable protection to be fixed on wall / pole with necessary clamps as per existing or in road crossing as ordered of size 40 mm complete all as directed. ( Note :- Unit rate quoted is deemed to be inclusive of MS clamps required to be fixed on pole).
Supply, Laying, jointing & testing 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables conforming to IS 7098(Part-I)-1988, heavy duty with aluminium stranded conductor laid in trenches or passing through pipe of cross sectional area 95 sqmm 3.50 core with all fixing & connecting accessories complete all as specified & as directed. Note:- (i) Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule. (ii) The rate quoted by the bidder shall deemed to be inclusive of the cost of aluminium thimbles/lugs glands, terminal of suitable sizes."
All as per Srl item No 8.00 here-in- before but for 70 Sqmm 3.5 Core complete all as specified and as directed.
All as per Srl item No 8.00 here-in- before but for 50 Sqmm 3.5 Core complete all as specified and as directed.
All as per Srl item No 8.00 here-in- before but for 35 Sqmm 4 Core complete all as specified and as directed.
All as per Srl item No 8.00 here-in- before but for 25 Sqmm 4 Core complete all as specified and as directed.
All as per Srl item No 8.00 here-in- before but for 16 Sqmm 4 Core complete all as specified and as directed.
All as per Srl item No 8.00 here-in- before but for 10 Sqmm 2 Core complete all as specified and as directed.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for laying of cable and getting out in hard /dense soil complete all as directed.
Returning filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed
Removal of surplus excavated (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. of size 50 mm outer dia complete all as specified and as directed by the Engr-in-Charge.
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. of 75 mm outer dia complete all as specified and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning factory made LT feeder pillar box (KIOSK) in repairs outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces of panel. The TPN aluminium bus bar not less than the 1.5 times the rated capacity of the incommer MCCB including 50x50x6mm thick angle iron frame work upto height of 0.9mtr above ground level (duly painted with synthetic enamel paint over a coat of red oxide primer on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing feeder pillar box complete all as specified and as directed. (Sirwani Bldg T-4 to 10) (a) Main incoming MCCB FP 125 Amps, 415 volts, 25 KA- 01 Each (Legrand CAT No. 4200 02) (b) MCCB FP 40 Amps 415 volts 16 KA-03 Each (Legrand Cat No. 4200 46) (c) MCB TPN 32 Amps-415 Volt 10 KA- 01 Each (Legrand Cat No. 4087 91) (d) MCB TPN 40 Amps - 415 volt 10 KA - 02 Each (Legrand Cat No. 4087 92) (e) MCB TPN 06 Amps 415 volt 10 KA -01 Each (Legrand Cat No. 4087 83) (f) MCB SPN 06 Amps 240 volt 10 KA - 01 Each (Legrand Cat No. 4087 38) (g) Digital Ammeter - 01 Each with suitable CTs (h) Digital voltmeter - 01 Each (j) RYB Indicators- 01 Set (k) Insulated cable glands for entry of cable to panel - 9 Each Note : Panel maker be CPRI approved. Flooring and mounting of panel to a newly constructed plateform of suitable size shall be measured and paid for separately.
Supply, installation, testing and commissioning factory made LT feeder pillar box (KIOSK) in repairs outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces of panel. The TPN aluminium bus bar not less than the 1.5 times the rated capacity of the incommer MCCB including 50x50x6mm thick angle iron frame work upto height of 0.9mtr above ground level (duly painted with synthetic enamel paint over a coat of red oxide primer on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing feeder pillar box complete all as specified and as directed. (Sirwani Bldg T-11) (a) Main incoming MCCB FP 125 Amps, 415 volts, 25 KA- 01 Each (Legrand CAT No. 4200 02) (b) MCCB FP 40 Amps 415 volts 16 KA-03 Each (Legrand Cat No. 4200 46) (c) MCB TPN 32 Amps-415 Volt 10 KA- 01 Each (Legrand Cat No. 4087 91) (d) MCB TPN 40 Amps - 415 volt 10 KA - 02 Each (Legrand Cat No. 4087 92) (e) MCB TPN 06 Amps 415 volt 10 KA -01 Each (Legrand Cat No. 4087 83) (f) MCB SPN 06 Amps 240 volt 10 KA - 01 Each (Legrand Cat No. 4087 38) (g) Digital Ammeter - 01 Each with suitable CTs (h) Digital voltmeter - 01 Each (j) RYB Indicators- 01 Set (k) Insulated cable glands for entry of cable to panel - 9 Each Note : Panel maker be CPRI approved. Flooring and mounting of panel to a newly constructed plateform of suitable size shall be measured and paid for separately.
Supply, installation, testing and commissioning factory made LT feeder pillar box (KIOSK) in repairs outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces of panel. The TPN aluminium bus bar not less than the 1.5 times the rated capacity of the incommer MCCB including 50x50x6mm thick angle iron frame work upto height of 0.9mtr above ground level (duly painted with synthetic enamel paint over a coat of red oxide primer on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing feeder pillar box complete all as specified and as directed. (Sirwani Bldg T-22 & 23) (a) Main incoming MCCB FP 125 Amps, 415 volts, 25 KA- 01 Each (Legrand CAT No. 4200 02) (b) MCCB FP 40 Amps 415 volts 16 KA-03 Each (Legrand Cat No. 4200 46) (c) MCB TPN 32 Amps-415 Volt 10 KA- 01 Each (Legrand Cat No. 4087 91) (d) MCB SPN 06 Amps 240 volt 10 KA - 01 Each (Legrand Cat No. 4087 38) (e) Digital Ammeter - 01 Each with suitable CTs (f) Digital voltmeter - 01 Each (g) RYB Indicators- 01 Set (h) Insulated cable glands for entry of cable to panel - 9 Each Note : Panel maker be CPRI approved. Flooring and mounting of panel to a newly constructed plateform of suitable size shall be measured and paid for separately.
Supply, installation, testing and commissioning factory made LT feeder pillar box (KIOSK) in repairs outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces of panel. The TPN aluminium bus bar not less than the 1.5 times the rated capacity of the incommer MCCB including 50x50x6mm thick angle iron frame work upto height of 0.9mtr above ground level (duly painted with synthetic enamel paint over a coat of red oxide primer on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing feeder pillar box complete all as specified and as directed. (Sirwani Bldg CHDH) (a) Main incoming MCCB FP 125 Amps, 415 volts, 25 KA- 01 Each (Legrand CAT No. 4200 02) (b) MCCB FP 40 Amps 415 volts 16 KA-03 Each (Legrand Cat No. 4200 46) (c) MCB TPN 32 Amps-415 Volt 10 KA- 01 Each (Legrand Cat No. 4087 91) (d) MCB SPN 06 Amps 240 volt 10 KA - 01 Each (Legrand Cat No. 4087 38) (e) Digital Ammeter - 01 Each with suitable CTs (f) Digital voltmeter - 01 Each (g) RYB Indicators- 01 Set (h) Insulated cable glands for entry of cable to panel - 7 Each Note : Panel maker be CPRI approved. Flooring and mounting of panel to a newly constructed plateform of suitable size shall be measured and paid for separately.
Supply, installation, testing and commissioning factory made LT feeder pillar box (KIOSK) in repairs outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces of panel. The TPN aluminium bus bar not less than the 1.5 times the rated capacity of the incommer MCCB including 50x50x6mm thick angle iron frame work upto height of 0.9mtr above ground level (duly painted with synthetic enamel paint over a coat of red oxide primer on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing feeder pillar box complete all as specified and as directed. (Sirwani Bldg CHDH) (a) Main incoming MCCB FP 125 Amps, 415 volts, 25 KA- 01 Each (Legrand CAT No. 4200 02) (b) MCCB FP 40 Amps 415 volts 16 KA-02 Each (Legrand Cat No. 4200 46) (c) MCB TPN 32 Amps-415 Volt 10 KA- 01 Each (Legrand Cat No. 4087 91) (d) MCB SPN 06 Amps 240 volt 10 KA - 01 Each (Legrand Cat No. 4087 38) (e) Digital Ammeter - 01 Each with suitable CTs (f) Digital voltmeter - 01 Each (g) RYB Indicators- 01 Set (h) Insulated cable glands for entry of cable to panel - 5 Each Note : Panel maker be CPRI approved. Flooring and mounting of panel to a newly constructed plateform of suitable size shall be measured and paid for separately.
Supply, installation, testing and commissioning factory made LT feeder pillar box (KIOSK) in repairs outdoor type platform mounted, CPRI approved suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having busbar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 CRCA steel sheet with double door shutter and locking arrangement, openable from front & back both including powder coated on both outer and inner surfaces of panel. The TPN aluminium bus bar not less than the 1.5 times the rated capacity of the incommer MCCB including 50x50x6mm thick angle iron frame work upto height of 0.9mtr above ground level (duly painted with synthetic enamel paint over a coat of red oxide primer on exposed surfaces) with and including following spares and including dismantling of old unserviceable existing feeder pillar box complete all as specified and as directed. (a) MCCB 4 pole, 16 KA 100 Amp -01 No. (Incommer) (Legrand Cat No. 4200 05) (b) MCCB 4 pole, 16 KA 63 Amp-03 Nos (Outgooing) (Legrand Cat No. 4200 03) (c) Phase indicating lamps (R-Y-B) - 01 Set (e) Digital Ammeter - 01 Each with suitable CTs (f) Digital voltmeter - 01 Each (g) RYB Indicators- 01 Set (h) Insulated cable glands for entry of cable to panel - 5 Each Note : Panel maker be CPRI approved. Flooring and mounting of panel to a newly constructed plateform of suitable size shall be measured and paid for separately.
S&F loop in-loop junction box of internal dimension 155x210x92mm made out of polycarbonate and locking arrangement incl 6 amps MB-1 No, 20 Amps rated 4 way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on steel tubular poles including necessary clamps, suitable glands, lugs and GI nut and bolts inlcuidng taking down old unserviceable junction box complete all as specified and as directed. Make : Hensel Cat No. : KF 1616 G or Sintex/OBO.
S&F MCCB 125 Amps, 4 Pole, 18 KA, Ics = 100% (Icu), 415 Volts 50 Hz, AC, suitable for existing LT panel/feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. (Make: Cat Part No: Havells cat No IHLANF0125 or or equivalent approved make)
S&F MCCB 100 Amps, 4 Pole, 18 KA, Ics = 100% (Icu), 415 Volts 50 Hz, AC, suitable for existing LT panel/feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. (Make: Cat Part No: Havells cat No IHLANF0100 or eor equivalent approved make)
S&F MCCB 63 Amps, 4 Pole, 18 KA, Ics = 100% (Icu), 415 Volts 50 Hz, AC, suitable for existing LT panel/feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. (Make: Cat Part No: Havells cat No IHLANF0063 or or equivalent approved make.)
M&L for Earthing complete in repairs with Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED (80-100) microns with pure Zinc(99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3043.The outer and inner pipe should be 48.3mm &26.4mm 2mtrs Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed inthe pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity ,The job includes digging the pits and refilling the same by BARONS Electrodite OR Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS Certification from NABL accredited lab. The earth pit should be provided with a FRP OR EPCC earth pit cover for protection and safe guard of terminals. In areas where soil condition is bad, GOOD EARTH ie BLACK COTTON OR MOISTUROUS NORMAL SOIL is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2 TO 4 bags ELECTRODITE 0R 2-4 BAGS CONDUCTILITE BFC FOR INSTALLATION OF EARTH ELECTRODE. The electrode should be of galvinised (80-100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm, 7.5 m. including excavation earthwork etc connected to electrical eqpts/panels and testing on completion all as specified and directed by Engineer in charge.
Supply & fixing 1.5 Sq.mm 3 core, 240volts Copper Conductor cable heavy duty PVC insulated, round sheathed ISI marked in PVC conduit all as specified and directed by Engr In charge
M&L for painting to steel tubular pole 9/11 Mtr long any type with applying two coats of aluminium paint over a coat of primer after preparation of surface of the pole including numbering of pole complete all as specified and as directed.
M&L for cable end termination kit indoor/outdoor, heat shrinkable type suitable for XLPE/PVC cables of size 25 Sqmm to 50 Sqmm 3 1/2 core with working voltage 1100 volts complete all as specified and as directed.
M&L for cable end termination kit indoor/outdoor, heat shrinkable type suitable for XLPE/PVC cables of size 70 Sqmm to 150 Sqmm 3 1/2 core with working voltage 1100 volts complete all as specified and as directed.
M&L for cable jointing kit indoor/outdoor, heat shrinkable type suitable for XLPE/PVC cables of size 25 to 70 Sqmm 3 1/2 core with working voltage 1100 volts complete all as specified and as directed.
M&L for cable jointing kit indoor/outdoor, heat shrinkable type suitable for XLPE/PVC cables of size 70 to 150 Sqmm 3 1/2 core with working voltage 1100 volts complete all as specified and as directed.
M&L for Plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregates as finishing road/concrete surface / coping of poles including finishing to exposed concrete surfaces even and fair complete all as specified.
Supply and install AC three phase LT CT operated TRIVECTOR METER of accuracy class 0.5 as per IS 14697 : 99, 3 x 240 volt, 50 Hz with optical & RS232 port, Backlit LCD display, measures & displays trivector energy, load survey, TOD, Tamper detection & logging, Power ON/Off events, instaneous parameters of rating 5 A with display in absence of power complete all as specified and as directed. Make- L&T(WR300BC52RS)/CG/ Schnieder/ABB. Note :- (a) CT of different ratio will be measured and paid separately. (b) Connecting wire from CT to Trivector Meter through superior quality and suitable size deed to be included in the item rate.
Supply and install following AC LT-CT of accuracy class 0.5 into the existing supply system after dismantaling the main cable terminals or busbar as directed of following rating 200A/5A
Supply and install following AC LT-CT of accuracy class 0.5 into the existing supply system after dismantaling the main cable terminals or busbar as directed of following rating 400A/5A
Supply & install three phase meter box size not less than 700x450x250mm made out of UV stabilized transparent polycarbonate/flame retardant high grade engineering plastic hinge type suitable for AC three phase LT-CT Trivector Meter, including fixing CTs. Make :- Sintex or other equivalent make as approved by GE. Note:- Fixing clamp/arrangement for meter box deemed to be included in the item rate.
S&F in repairs busbar chambers 4 way 100 Amps outdoor type (IP-65/66) pole/wall mounted including provision of fixing on pole by means of suitable size of clamps with nuts and bolts including necessary connection including taking down old unserviceable one complete all as specified and as directed.
M/S S. S CHETTRI AND SONS
M/S ANIL KUMAR THAKUR
NISHA CONSTRUCTIONS
DHARMINDER SINGH
KAMLESH ENTERPRISE
KARMA SHERPA
M/S MANOJ VERMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .