Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹8.7 L
EMD Value
₹8,800
Closing Date
28 Oct 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer
Office of the Executive Engineer PWD Building C and M Division Erode
Special Repairs to Leaky Roof, Water Supply and Sanitary Arrangements for HSC Building at Chinnaveerasangili in Perundurai, Erode District
2026_PWD_713701_1
NIT.09 2026 27 BCM DIVISION ERODE Dated 13.10.2026
Open Tender
Maintenance Works
Percentage
Chinnaveerasangili
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹8,800
13 Oct 2026
13 Oct 2026
28 Oct 2026
13 Oct 2026
28 Oct 2026
13 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Chipping of concrete & roughening the surface etc., complete as per standard specification and as directed by the deparmental officers. | 39.01 | M2 | 43.2 | ₹1,685.23 |
| 2 | Dismantling and carefully stacking the materials useful for reuse of Pressed tiles & weathering course, etc., complete as per standard specification and as directed by the deparmental officers. | 42 | M2 | 49.2 | ₹2,066.4 |
| 3 | Dismantling clearing away and carefully stacking the materials useful for reuse of Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs etc., complete as per standard specification and as directed by the deparmental officers. | 4.41 | M2 | 65.56 | ₹289.12 |
| 4 | Earth work excavation for foundation by manual means (for narrow excavation) in all soils and sub soils and to full depth as may be directed except in rock requiring blasting, but inclusive of shoring, strutting and baling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of not more than 15cm thick, well rammed, consolidated and depositing the surplus earth within the compound in places shown by the departmental officers with initial lead and lift etc., complete complying with standard specifications as directed by the departmental officers (By manual means) | 60.46 | M3 | 196.95 | ₹11,907.6 |
| 5 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers | 39.01 | M2 | 330.7 | ₹12,900.61 |
| 6 | Flooring with ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) | 4.41 | M2 | 1,157.8 | ₹5,105.9 |
| 7 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). | 1 | No | 5,907 | ₹5,907 |
| 8 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). | 2 | Nos | 4,165.3 | ₹8,330.6 |
| 9 | Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level -25mm diametre UPVC PIPE.. | 30 | RM | 292.25 | ₹8,767.5 |
| 10Supplying, laying and jointing UPVC Specials (Unplasticized polyvinyl chloride) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (both in internal and external water supply arrangements)Note:Since the labour for cutting,threading/pasting,sundries have already been included under pipe line item of works,no separate provision for fixing UPVC specials needs to be allowed. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
Tencon_Chinnaveera.pdf
Tender Documents • 2.15 MB
BOQ_857427.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .