Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC | ₹44.8 L Quoted ₹45.5 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹47.6 LRejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | ₹47.6 L | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹48.0 LRejected-Finance | ₹48.0 L | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹48.0 LRejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 UDYAM WB 08 0026730 19BFZPJ6726D1ZW R M MSME STATUS AS NOT VERIFIED | HOWRAH | WEST BENGAL | 711202 | ₹48.0 L | L4 | Rejected-Finance Not lowest bidder |
| 5 | L5₹48.6 LRejected-Finance PO BANARHAT DIST JALPAIGURI WB PIN 735202 | JALPAIGURI | WEST BENGAL | 735202 | ₹48.6 L | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | Shree Ram Construction L1 | M/S SUPARNA ELECTRICALS L3 | SHRI SANJAY KUMAR GUPTA L5 | SARKAR ENGINEERING CO. L6 | M/S BENGAL ENGINEERING ENTERPRISES L7 | MS ORIENT ENGINEERING WORKS L2 | Janata Enterprises L8 | M/S R. K. INDUSTRIES L4 | BEEPEE AND COMPANY L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for following repair, serviceing and replacement of unserviceable accessories of LT Panel any make type/size including welding, brazing and drilling work:-
(a) Tightening of all loose conectiont of cable inside the panel and welding the broken door of the panel.(b) Clean all the rusted busbar through hemry paper and fixing insulation heat shrink sleeves through out the busbar including strip connected with out going MCCB. (c) Cut the damage insulation portion end of cable inside the panel and reconnecting its into positions after fixing the end termintion/Sleeves complete with suitable size of aluminium lugs and stainless steel nut bolts. (d) Repair/Replacement of burn/unserviceable voltmeter, ammeter,indication lamp contactor including control wiring of the panel between voltmeter, Ammeter and their selector switch and CTs . (e) Repair/Replacement of all burn lugs inside the panel.(f) Replaced all the GI rusted nut, bolts,and washers with made of stainless steel nuts, bolts and washers.(g) Clean the dust inside the panel by air blower/vaccum cleaner complete.
Note : (a) The cost of nut bolts, washers, insulation tape, lugs, etc essentially required to make the panel serviceable shall be deemed to be included in the quoted rate.
(b) Other spare parts/accessories shall measured and paid separately under relevant items of schedule.
(c) Excavation of loop shall be measured and paid separatly. | 16 | Each Job | 6,900 ₹1.1 L | 7,422 ₹1.2 L | 7,350 ₹1.2 L | 7,580 ₹1.2 L | 7,500 ₹1.2 L | 7,500 ₹1.2 L | 7,450 ₹1.2 L | 7,350 ₹1.2 L | 7,100 ₹1.1 L |
| 2.00 | Supply only epoxy type insulator for support of busbar grade 1100 volt as per existing size. | 20 | Each | 95 ₹1,900 | 96 ₹1,920 | 93 ₹1,860 | 98 ₹1,960 | 118 ₹2,360 | 105 ₹2,100 | 100 ₹2,000 | 102 ₹2,040 | 105 ₹2,100 |
| 3.00 | Material only for control wiring of the panel with 1.5 sq mm multistranded, PVC insulated copper conductor 1100 Volt grade FRLS cable. | 100 | RM | 55 ₹5,500 | 58 ₹5,800 | 58 ₹5,800 | 59 ₹5,900 | 65 ₹6,500 | 58 ₹5,800 | 60 ₹6,000 | 57 ₹5,700 | 62 ₹6,200 |
| 4.00 | Supply only LED phase indicator lamp colour RED/YELLOW/GREEN AC 220 Volt 50 Hz. | 20 | Set of Three | 284 ₹5,680 | 302 ₹6,040 | 300 ₹6,000 | 317 ₹6,340 | 282 ₹5,640 | 322 ₹6,440 | 300 ₹6,000 | 289 ₹5,780 | 300 ₹6,000 |
| 5.00 | Supply only LED phase indicator lamp colour BLUE 220 Volt 50 Hz. | 20 | Each | 385 ₹7,700 | 404 ₹8,080 | 418 ₹8,360 | 406 ₹8,120 | 435 ₹8,700 | 415 ₹8,300 | 450 ₹9,000 | 396 ₹7,920 | 415 ₹8,300 |
| 6.00 | Supply only LED phase indicator lamp colour WHITE AC 220 Volt 50 Hz. | 20 | Each | 385 ₹7,700 | 405 ₹8,100 | 418 ₹8,360 | 407 ₹8,140 | 435 ₹8,700 | 415 ₹8,300 | 450 ₹9,000 | 397 ₹7,940 | 415 ₹8,300 |
| 7.00 | Supply only LED phase indicator lamp colour AMBER AC 220 Volt 50 Hz. | 5 | Each | 385 ₹1,925 | 405 ₹2,025 | 418 ₹2,090 | 407 ₹2,035 | 435 ₹2,175 | 415 ₹2,075 | 450 ₹2,250 | 397 ₹1,985 | 415 ₹2,075 |
| 8.00 | Supply only cast resin insulated type CT, Ratio 300/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 1second. | 2 | Set of three | 3,287 ₹6,574 | 3,510 ₹7,020 | 3,500 ₹7,000 | 3,777 ₹7,554 | 3,280 ₹6,560 | 3,600 ₹7,200 | 3,500 ₹7,000 | 3,820 ₹7,640 | 3,500 ₹7,000 |
| 9.00 | Supply only cast resin insulated type CT, Ratio 400/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 1second. | 2 | Set of three | 3,287 ₹6,574 | 3,490 ₹6,980 | 3,500 ₹7,000 | 3,690 ₹7,380 | 3,280 ₹6,560 | 3,600 ₹7,200 | 3,500 ₹7,000 | 3,790 ₹7,580 | 3,500 ₹7,000 |
| 10.00 | Supply only copper bus bar any size (5x20, 10x20, 10x25, 10x40, 10x50,10x80) mm duly insulated with heat shrink busbar insulation sleeves. | 15 | Kg | 1,250 ₹18,750 | 1,380 ₹20,700 | 1,355 ₹20,325 | 1,320 ₹19,800 | 1,400 ₹21,000 | 1,245 ₹18,675 | 1,300 ₹19,500 | 1,255 ₹18,825 | 1,340 ₹20,100 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Feb 2026, 6:00 pmClosed
GARRISON ENGINEER
Bengdubi Military Station PO-Bengdubi, Dist-Darjeeling, Pin 734424
REPAIR REPLACEMENT MAITENANCE AND SERVICING OF LT PANELS ACBs UPDATION OF SOFTWARE OF SYNCHRONATION PANELS CABLES APFC PANELS AND ALLIED WORKS OF BASE HOSPITAL UNDER AGE EM OF GE BENGDUBI
2026_MES_750738_1
8779/E8
Open Tender
Civil Works
180 days
GARRISON ENGINEER BENGDUBI
Please refer NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER
₹90,000
Yes
5 Mar 2026
31 Jan 2026
23 Feb 2026
31 Jan 2026
21 Feb 2026
14 Feb 2026
1 Feb 2026 - 7 Feb 2026
Supply only epoxy type insulator for support of busbar grade 1100 volt as per existing size.
Material only for control wiring of the panel with 1.5 sq mm multistranded, PVC insulated copper conductor 1100 Volt grade FRLS cable.
Supply only LED phase indicator lamp colour RED/YELLOW/GREEN AC 220 Volt 50 Hz.
Supply only LED phase indicator lamp colour BLUE 220 Volt 50 Hz.
Supply only LED phase indicator lamp colour WHITE AC 220 Volt 50 Hz.
Supply only LED phase indicator lamp colour AMBER AC 220 Volt 50 Hz.
Supply only cast resin insulated type CT, Ratio 300/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 1second.
Supply only cast resin insulated type CT, Ratio 400/5A with capable of withstanding momentary short circuit and symmetrical short circuit for 1second.
Supply only copper bus bar any size (5x20, 10x20, 10x25, 10x40, 10x50,10x80) mm duly insulated with heat shrink busbar insulation sleeves.
M&L for spray painting in existing steel surface of Panel/FPB/JB etc with two coats of synthetic enamel including one coat red oxide in rusted area after proper cleaning and prepration of old painted surfaces steel / Iron of any description with spray machine complete all as specified and directed. (Note:- Painting of panels / feeder filler boxes shall be carried out in different colour of paints as required at site and as directed.
M & L for repair, serviceing, release testing and comprehensive maintenance of fully automatic Air Circuit Breaker (ACB) of all LT panel and capacitor panel . Repair/maintenance work comprisr the followings:- (a) Disconnecting the ACB from existing position and opening, cleaning the dust of all contact points , servicing by using CRC and throughly cheking to detect the any fault then rectified the same by supplying and replacing the defect parts and after rectified the fault refitted the ACB in its position and commossioning and testing the panel . (b) Opening the panel and cleaning dust of the panel through vaccum cleaner, blower should not be used for cleaning. (c) After cleaning , checking the all cable connection, Busbar joint and tightening the loose connection and oiling all the nut Bolt of the same.(d) Cleaning and checking the servicibity condition of all the relays, contactor, fuse, Indicator switch, push buttom, control wiring, connector and replacing all the burn out parts assembled the panel i.e contactor, relay with new one.
Supply only aux contactor MX0 31E (3NO +1NC) operating voltage 240 Volt AC
Supply only aux contactor MX0 31E (3NO +1NC) operating voltage 110 Volt DC
Supply only aux contactor MX0 22E (2NO +2NC) operating voltage 240 Volt AC
Supply only aux contactor MX0 22E (2NO +2NC) operating voltage 110 Volt DC
Supply only aux contactor MXO 40E (4NO) operating voltage 240 Volt AC
Supply only Panel control switch (TNC 02 NO + 02 NC) operating voltage 240 Volt AC
Supply only XT series HMI size 4.5 inch with colour TFT display option with ethernet model, touch screep higher brightness level upto 440cd/m2 long backlight life upto 50000 hours for display, shock and vibration protection as per IEC standard, RAM 32 Mb and ROM 128 MB all as per specified and directed by Engr-in charge. complete all as specified and directed.
Supply only Instantaneousdifferential protection relay CAG Type CT Sec 1 amp Model No CAG34AF71A
Supply only push buttons red, green, yellow and black with aux contacts 1 NO and 1 NC all as specified and directed.
Supply only flush type micro processor based alarm annunciator with P.B window 08 and aux voltage 110 Volt DC as per sample in site in complete all as specified and directed.
Supply only Hooter flush type 96 x 96 mm aux voltage 110 Volt DC as per sample in site in complete all as specified and directed.
Supply only shunt release for ACB supply voltage 110 VDC as per sample in existing size all as specified and directed.
Supply only Closing release for ACB supply voltag 240 Volt AC as per sample of existing in site all as specified and directed by Engr-in-charge.
Supply only under voltage trip device for ACB supply voltage 415 Volt AC as per sample of existing in site all as specified and directed by Engr-in-charge.
Supply only automatic spring charge motor operating voltage 220 Volt AC for ACB as per sample of existing in site all as specified and directed by Engr-in-charge.
Supply only Door interlock of ACB as per sample of existing in site all as specified and directed.
Supply and fixing repair of Microprocessor SP-UW MTX3.5EC Release suitable for Omega ACB as per sample at existing site all as specified and directed .
Supply only automatic power factor controller EPCOS BR 6000 12 stage operating voltage 240 VAC all as specified and directed
Supply only Power contactor 3phase AC3 ratin 110A and AC1 rating 160 amp Type MNX 110 with 2 NO + 2NC all as specified and directed.
Supply only Power contactor 3phase AC3 rating 80A and AC1 rating 1100 amp Type MNX 80 with 2 NO + 2NC all as specified and directed.
Supply only PVC cable 6 sq mm 4 core copper conductor FRLS multidtranded with rope insulation complete all as specified and as directed.
Supply and fixing Copper lugs 10 sq mm all as specified and directed.
Supply and fixing Copper lugs 16 sq mm all as specified and directed.
Supply and fixing Copper lugs 25 sq mm all as specified and directed.
supply and fixing in repair LT APP box type capacitor bank capacity 25 KVAr 440 V AC 3 Ph 50 Hz all as specified and directed.
supply and fixing in repair LT APP box type capacitor bank capacity 50 KVAr 440 V AC 3 Ph 50 Hz all as specified and directed.
Supply and fixing Under Voltage and Over Voltage Minilec Relay 415 Volt AC as per sample at existing site all as specified and directed.
Supply and fixing Bridge rectifire Input Voltage 240 Volt Ac all as specified and directed.
Supply only of CS7-12 chloride safepower , SMF type sealed Lead acid Battery capacity 12 Volt 7 Ah used for UPS backup alll as specified and directed.
Supply only Eaton Bussman series 170M1565D high speed square body fuse 690 V (IEC) 63A 700 Volt AC , Combination fuse indication indicator blade end all as specified and directed.
Supply and fixing in repair of PLC (Programmable Logic Controller) Series SIMATIC S7 200 SMART for DG Synchronisation Panel/Main power supply synchronisation panel all as specified and directed.
M&L for PLC programming and updation of software of DG Synchronisation Panel and Main power supply synchronisation panel all as specified and directed.
Supply and fixing in repair of Battery charger Mahamai 24 VDC 16 Amp all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron 25x4mm earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 15mm bore light grade GI pipe for protection of earth lead including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing all as specified & directed.
S&F in repairs MCCB 160 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA, Ics=100 % ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
S&F in repairs MCCB 200 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA,Ics=100 % ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
S&F in repairs MCCB 250 Amps, 4 Pole, 415 V, Adjustable type, with breaking capacity 36 KA, 100 % ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
S&F in repairs MCCB 320 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 36 KA, Ics=100% ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
S&F in repairs MCCB 600 Amps, 4 Pole, 415 V, adjustable type, with breaking capacity 50 KA, Ics=100% ICU including spreader terminals & connected accessories both ends complete all as specified and directed.
Taking out old unserviceable under ground cable of any size and any position from trenches, floors and wall and segrate the serviceable portion cable for reuse complete all as specified and directed.
Supply and laying XLPE insulated armoured (under ground) heavy duty electic cable with stranded aluminim conductor 1100 volts grade of crossectional area 150 Sqmm 3.5 core laid in trenches/ducts/through pipes/in floor road/along the pole etc all as specified & directed by Engr-in-charge. Note : (a) Excavation earth work, brick protection and cushioning shall be measured & paid separately.
Excavation in trenches in soft loose soil including cutting road surfaces n.exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for poles, stay, cable, pipe etc getting out all as specified.
Returning, filling in, including spreading, leveling,watering and well ramming in layers each n.exc 25 cm thick in soft loose soil all as specified.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay brick common burnt sub class "B" old size (compressive strength not less than 75 kg per sqcm) for protection of cable laid in trenches for under ground cable all as specified.
M & L for Sand cushioning trenches using fine sand to under ground cable, laid in two layers 15cm before laying the cable & 8cm after laying the cable complete all as specified and directed.
Labour for drilling hole under the road with the help of bocki / by manual or by machine for crossing GI tubing of size 100 mm pipe for cable protection all as specified and directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 53,050.00 The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TENDER8779.pdf
Tender Documents • 0.88 MB
BOQ_840818.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid