Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC 17 23 K P ROY LANE KOLKATA 700 031 | KOLKATA | KOLKATA | WEST BENGAL | 700031 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹14.3 L+₹2.0 L (16.1%)Rejected-Finance | L2 | Rejected-Finance Quoting higher rate | |
| 3 | L3₹14.5 L+₹2.2 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Quoting higher rate | |
| 4 | L4₹16.7 L+₹4.4 L (35.9%)Rejected-Finance 1 C NEPAL BHATTACHARJEE STREET KALIGHAT KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L4 | Rejected-Finance Quoting higher rate | |
| 5 | L5₹17.1 L+₹4.8 L (38.7%)Rejected-Finance 13 11 MOTILAL GUPTA ROAD KOLKATA 700 008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | L5 | Rejected-Finance Quoting higher rate |
Tender Value
Refer Docs
EMD Value
₹31,700
Closing Date
16 Jul 2025, 1:00 pmClosed
The Executive Engineer PWD,ECD
New office Complex Building(5th Floor) Bhabani Bhawan Alipore, Kolkata 700027
Temporary EI Work incl hiring of DG Sets for Stadium Flood Lights and broadcasting in connection with the upcoming 134th Durand Cup Tournament 2025 at Kishore Bharati Krirangan, Jadavpur,Kolkata.
2025_WBPWD_871126_1
WBPWD/EE-ECD/e-NIQ-15/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
13 days
Jadavpur
please refer tender documents
5 documents required · 5 mandatory
₹31,700
O/O The Executive Engineer PWD ECD
22 Aug 2025
26 Jun 2025
18 Jul 2025
26 Jun 2025
16 Jul 2025
3 Jul 2025
26 Jun 2025 - 2 Jul 2025
2 Jul 2025
Amount
Supply & drawing on hire basis 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire of following size in polythene pipe incl. making necy. connection as required for circuit wiring and branch wiring and dismantling the same after the function/programme as per direction of E.I.C
2 x4 + 1x2.5 sqmm ( Up to 3 days).
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty = 235 Mtr. X10 No of Days = 2350 mtr)l
Supply & drawing on hire basis 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire of following size in polythene pipe incl. making necy. connection as required for circuit wiring and branch wiring and dismantling the same after the function/programme as per direction of E.I.C
2 x2.5 + 1x1.5 sqmm (Up to 3 days.)
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty =350 Mtr. X 10 No of Days = 3500 mtr)
Providing on hire basis 200 W/150 W LED flood light to be fixed properly with clamping arranegent & other fixing accessories as required alongwith earthing attachment and dismantling the same after the function/programme as per direction of E.I.C. ( Up to 3 days.)
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty =30 Set. X10 No of Days = 300 Sets)
Providing on hire basis 600mm. Sweep Air-Circulator fan of metal body with earthing attachment and dismantling the same after the function/programme as per direction of E.I.C (Up to 3 days)
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty =20 Set. X 10 No of Days = 200 Sets)
Providing on hire basis 5/15A combined multi plug socket (5 nos) with necy connection & earthing attachment and dismantling the same after the function/programme as per direction of E.I.C (Up to 3 days)
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty =30 Set. X 10 No of Days = 300 Sets)
Providing on hire basis of following switches and DBs(make as approved by E.I.C) on wooden plank board with suitable angle iron frame including inter-connection with suitable size of copper wire with proper socketing, earthing, attachment etc. and dismantling the same at the end of the programme as per direction of EIC
(a) 415 volts upto 6 way MCB PBDB with 6-32 Amp. Per way as outgoings and 1no.-63 Amp. 4- Pole MCB isolator as incoming (Up to 3 days)
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty =2 Set. X 10 No of Days = 20 nos)
(b) 240 volts upto 2+12 way SPN MCB DB with 6-32 Amp. Per way as outgoings and 1no.-63/40 Amp. DP MCB isolator (Up to 3 days)
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty =4 Set. X 10 No of Days = 40 nos)l
(c) Providing on hire basis 125 A Change over switch with necy connection and dismentling the same (Up to 3 days)
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty =1 Set. X 10 No of Days = 10 nos)l
Providing on hire basis 1.1 KV grade 4 core 25/35 & 2 core 10 sqmm cable Aluminium Conductor PVC / XLPE armoured cable with necy connection including dismantling the same after function/programme and mending good the damages (Up to 3 days)
[Next 10 Days after 3 Days. (@ 2% of the rate of first 3 days per day.) (Qty = 200 Mtr. X 10 No of Days = 2000 mtr)l
Supply and Providing on hire basis 415V 500 KVA 3-phase 50Hz silent type DG Set (not more than 7 years old) of suitable generator of reputed make for Flood lighting system including providing of 1.1kV grade of 3run 4/3.5 core 240sq mm Al/A cable or equivalent of similar current carrying capacity cable (maximum length -250mtr. in each run) (From DG set to LT panel) with 4 nos proper earthing for neutral and body and dismantling the same after completion of event including proper socketing, gland, etc with suitable interconnection and provide sufficient manpower with tools and tackles for maintenance and operation arrangement for each DG setand the installation round the clock. (4 nos DG Set X 5 match days + 4 nos DG set X 5 Testing days before match days= 40set)
Supply and Providing on hire basis 415V 62.5 KVA 3-phase 50Hz silent type DG Set (not more than 7 years old) of suitable generator of reputed make for Broadcasting including providing of 1.1kV grade of 3run 4/3.5 core 50sq mm Al/A cable or equivalent of similar current carrying capacity cable (maximum length -250mtr. in each run) (From DG set to LT panel) with 4 nos proper earthing for neutral and body and dismantling the same after completion of event including proper socketing, gland, etc with suitable interconnection and provide sufficient manpower with tools and tackles for maintenance and operation arrangement for each DG setand the installation round the clock.(1 nos DG Set X 5 match days + 1 nos DG set X 5 Testing days before match days= 10 set)
Hiring charge for supply, installation, testing & commissioning 4.5 TR Tower type Air conditioners(reputed make/brand make as approved by E.I.C including on temporary basis incl. placement of outdoor & indoor unit in proper way & safe position with all interconnection of refrigeration copper piping, arrangement of water drainage piping pipe including all necessary electrical inter-connection and earthing attachment as per direction of E.I.C (4 noss Machines X 5 match days = 20 nos.)
Hiring charge for supply, installation, testing & commissioning 3.5 TR Tower type Air conditioners(reputed make/brand make as approved by E.I.C including on temporary basis incl. placement of outdoor & indoor unit in proper way & safe position with all interconnection of refrigeration copper piping, arrangement of water drainage piping pipe including all necessary electrical inter-connection and earthing attachment as per direction of E.I.C (1 no. Machine X 5 match days = 5 nos.)
Transportation charges incl. loading & unloading of the above-said materials for Electrical Installation from agency's godown to Kishore Bharati Krirangan & back to go-down after the end of the program.
Charges for providing/engagement of manpower in one shift on matchdays for looking after the afore-said temporary Electrical installation with all requisite tools & plants, material and ladder to attend any fault immediately and for all kind of E.I maintenance as per direction of EIC.
1nos. skilled Electrician
1 no unskilled labour
Cost of running Diesel cum Fuel consumption of the above-said DG sets during period of power cut-off/loadshedding as per Log book & TD sheet
M/S SAMRIDDHI ELECTRO & CO. (BID ID -6713604)
SINHA ELECTRIC (BID ID -6711015)
SHREE GANESH ENTERPRISE (BID ID -6721599)
S. K. CHATTERJEE ELECTRICALS PVT LTD (BID ID -6729587)
GHANASHYAM ELECTRIC STORES (BID ID -6730423)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .