EX. ENGINEER (ELECT)/Old Delhi Zone (CSPZ)
OFFICE OF THE EX. ENGINEER (ELECT)/Old Delhi Zone (CSPZ) UNDER GROUND CAR PARKING ASAF ALI ROAD, DELHI-110002
Provision of Retrofitting for 125 KVA DG set installed in GLM Hospital
2026_MCD_293917_2
44/MWEEE-I/2026-27/TC
Open Tender
Electrical Works
Percentage
90 days
Old Delhi Zone
refer special conditions
2 documents required · 2 mandatory
₹0
₹15,933
22 Oct 2026
9 Oct 2026
16 Oct 2026
9 Oct 2026
16 Oct 2026
9 Oct 2026
30 days
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | supply, installation, testing, commissioning of Retrofit Emission Control Device (RECD) for existing 125 KVA Diesel Generator (DG) sets for Phase II genset engine . The RECD shall be installed on DG exhaust system to reduce emissions and comply with CAQM Direction No. 76 and and guidelines and he system shall be type-approved by CPCB-recognized laboratory (ICAT/ARAI/IIP). RECD work should include Exhaust piping modification and supports, Supply and installation of control panel with monitoring system , Installation & integration with DG exhaust systerm etc as required .RECD shall be based on Catalytic oxidation/ particulate filtration system. System shall include Oxidation catalyst unit/ Passive particulate filter / regenerative trap .System shall operate passively (no external fuel or chemical dosing The RECD shall achieve minimum emission reduction as PM (Particulate Matter) ≥ 70% . HC (Hydrocarbons)≥ 70%. CO (Carbon Monoxide ≥ 70% .Smoke opacity ≥ 90% .Proven performance through type approval test reports Construction & Material should be Outer shell: SS 304 / SS 202 (minimum 3–5 mm thickness) . Internal filter media: Multi-layer metallic / alloy mesh/ Catalyst coated surfaces. Piping: IS 2062 / MS / SS as required and Corrosion resistant and heat resistant construction The RECD shall be supplied with a weatherproof control panel (IP65) having Digital display unit , Microcontroller / PLC-based monitoring .Monitoring Parameters should be Exhaust temperature (before RECD) ,Back pressure , System health status etc as required. The RECD system Back pressure should be withthin OEM DG permissible limits and No adverse impact on Engine performance , Fuel consumption. System shall be Maintenance-free / low maintenance and Without moving parts Minimum warranty: 12 months from commissioning and Life expectancy: 10–12 years | 1 | No | 1,41,600 | ₹1,41,600 |
| 2 | SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as
required. (Suitable for 400 Amp TP & N) | 3 | sqm | 13,027 | ₹39,081 |
| 3.1 | Providing & Fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling
the hole in cubical panel making the connection etc. as required. 250 Amp, 25KA, TPMCCB | 4 | Each | 12,984 | ₹51,936 |
| 3.2 | (b) 400 A, 35 KA,TPMCCB | 1 | Each | 22,644 | ₹22,644 |
| 4 | On Load Change Over Switch, 630 Amp, Open execution type, 2 Nos. one for DG set and one for phase sequence. | 2 | No | 33,820 | ₹67,640 |
| 5 | Supplying of PVC insulated, sheathed XLPE armoured copper cable confirming to IS: 7098 as required. (a) 4*6 sq mm | 90 | meter | 587 | ₹52,830 |
| 6 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient
sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. (a) 100 mm width X 50 mm depth X 1.6 mm thickness | 20 | meter | 623 | ₹12,460 |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required. (a) Single pole and neutral | 6 | No | 643 | ₹3,858 |
| 8 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*240 sqmm | 242 | meter | 1,401 | ₹3,39,042 |
| 9Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.84 MB
Tendernotice_2.pdf
PDF • 17.56 MB
Tendernotice_3.pdf
PDF • 0.68 MB
DNIT02_0001.pdf
Tender Documents • 9.15 MB
BOQ_342666.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .