Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC 45 58 5 15A AKSHAYA NARASIMHANAGAR VISAKHAPATNAM 530 024 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530024 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹38.6 L+₹57,110 (1.50%)Rejected-Finance H NO 9 9 1 1 DOCTOR S COLONY SHIVAJIPALEM VISAKHAPATNAM 530 017 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530017 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹39.4 L+₹1.4 L (3.58%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹40.1 L+₹2.1 L (5.44%)Rejected-Finance HARINAGAR BEHIND MAHESHWARY MARKET PO TATISILWAI DIST RANCHI PIN 835103 | RANCHI | JHARKHAND | 835103 | L4 | Rejected-Finance Being other than L1 | |
| 5 | Rejected-Technical H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | - | Rejected-Technical NOT QUALIFIED |
| Sl No | Description | Qty | Unit | Velox Engineering Solutions Pvt Ltd L1 | SATYAM ENGINEERS L3 | SERVO-TECH ENTERPRISES L2 | UNIVERSAL ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance and repairs of electrically operated lifts of 8 passenger/544 Kgs capacity - 10 Nos of Lifts, service G+5/G+4 upper floors with full collective / selective controal by carrying out periodical checks, repairs, attending to breakdowns and testing as specified to ensure smooth/ safe and efficient operation, including provision of consumables, renewal/ replacement of defective spares and fixing of spares given in spares list. Make of lift : IES (Industrial Engineering Systems).
Notes :
(i) The lifts shall be maintained and repaired through OEM or by their authorized / accredated agencies only.
(ii) Spares parts required to be replaced shall be measured and paid separately as supply only items. The unit rate quoted shall be deemed to inlcude the cost of Labour, T&P etc., for fixing spares. | 80 | JOB PER LIFT PER MONTH | 22,700 ₹18,16,000 Lowest | 23,583 ₹18,86,640 | 23,000 ₹18,40,000 | 24,000 ₹19,20,000 |
| 2.00 | Comprehensive maintenance and repairs of electrically operated lifts of 13 passenger/884 Kgs capacity - 10 Nos of Lifts, service G+5/G+4 upper floors with full collective / selective controal by carrying out periodical checks, repairs, attending to breakdowns and testing as specified to ensure smooth/ safe and efficient operation, including provision of consumables, renewal/ replacement of defective spares and fixing of spares given in spares list.
Make of lift : IES (Industrial Engineering Systems).
Notes :
(i) The lifts shall be maintained and repaired through OEM or by their authorized / accredated agencies only.
(ii) Spares parts required to be replaced shall be measured and paid separately as supply only items. The unit rate quoted shall be deemed to inlcude the cost of Labour, T&P etc., for fixing spares. | 80 | JOB PER LIFT PER MONTH | 23,300 ₹18,64,000 Lowest | 24,230 ₹19,38,400 | 23,500 ₹18,80,000 | 24,500 ₹19,60,000 |
| 2.01NOTE FOR ITEMS NO.1.00 & 2.00: FORTNIGHTLY MAINTENANCE/CHECKS (a) Check the alignment and operation of the Door operating mechanism at all landings (b) Check the action of the brake with lift in Operation (c) Check shoes, pulleys and lubricate (d) Check oil level and oil leakage in the gear | |||||||
| 2.02MONTHLY MAINTENANCE/CHECKS (a) Check the position of the operating cum in relation to the landing door and door locks (b) Clean lubricate pivot point and wherever requires (c) Lubricate the brake pin (d) Check suspension of ropes and anchorage and lubricate (e) Check over speed of governor and lubricate the required part (f) Make full ascent and decent to assess the quality of theride at all points | |||||||
| 2.03QUARTERLY MAINTENANCE/CHECKS (a) CAR (i) Clean light fixtures (ii) Check retiring cam device chain, dash pots, commutator brush cams, divots, fastenings. (iii) Check emergency switch/battery & Alarm bell (iv) Check safety points, set, screws, switches (b) Check trailing cables for evidence of chaffing orother constructions in the lift well check anchorages. (c) Inspect at every landing, landing doors, tracks,guidesand locks, fasteners and clean and lubricate them.4. Check function box for loose connections and also check mainline switch fuses for heating. (d) Check car and counter weight guides and shoes. (e) Check whether guide rail surface is smooth and clean. Also check the guide shoes for excessive wear & tear (f) Check and lubricate all bearings & gear box (g) Motor, Generators, Evictor : Clean all commentators and renew or reset brushes if necessary. (h) Ropes : Check all fastening inspect all rope for wear and lubricants (j) Leveling : Check leveling operation and switches | |||||||
| 2.04HALF YEARLY MAINTENANCE/CHECKS (a) Check door & gate operation, check shaft bearing alignment observation of cams rollers and check for the sign of wear (b) Check selector, signals and communications (c) Check sill channel for bends or cracks (d) Check contacts, switches clean and lubricate. (e) Check door contacts (f) Check shoes and pulleys for worn groves and check that all ropes tie at the same depth and check slippage of rope and condition. | |||||||
| 2.05(g) Run the machine in both direction and check sign of excessive play or back lash in gear. Check the overheatingor excessive bearing noise (h) Check oil level and oil leakage in the gear (j) In DC motors and MG sets check commutation for fitting or wear and for signs of undue sparking or brush chatter keeps them clean (k) Check brushes and ensure that spring for adjusting Brush pressure is adjusted to give enough pressure on the brushes. (l) Check the conditions of linings and couplings (m) Check the tightness of the coupling keys | |||||||
| 2.06ANNUAL MAINTENANCE/CHECKS (a) MACHINE ROOM (i) Examine all main switches for positive make and break of contacts. Check for loose connections (ii) Clean machine room and ensure proper earthing of motors, controllers, bed plates. | |||||||
| 2.07(b) CONTROL BOARD (i) Keeps the controller clean and free from dust (ii) Lubricate all moving parts and check for loose connection if any (iii) Check gap between armature and housing plate (iv) Check and clean all contact (v) Check transformer connections are tight or not (vi) Check resistors, capacitors and rectifiers. (vii) Check fuse ratings etc | |||||||
| 2.08(c) MACHINE UNIT (i) Check for any abnormality such as vibrations noisetemperature, alignment and check all grease cups and refill if required (ii) Check all bed plate and ensure that all bolts are tight and of the diverting pulley plates and rigid. (iii) Check motor/MG set/DC motor & Techno generatorfor oil levels up to the given marking in case of oil leakage change the oil seal and check the axial play rigidly and belt tension. (iv) GEAR UNIT : Overheating and leaking to be checked for gear box and must be filled with oil (ENKLO-320) (v) BREAK DRUM & COUPLINGS : Check that bolt, nuts, rubberbushes are in appropriate position(if the rubber bushesare found replace them) (vi) Check the running sound, if any unusual running sound develops rectify. (vii) Check that the diverter pulley and shaft (viii) Shift of fruition sleeve on shaft should be checked andrectified immediately. | |||||||
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
21 Feb 2026, 6:00 pmClosed
Garrison Engineer (I) (CG) Chennai
Garrison Engineer (I) (CG), P-16, CGRA Meenambakkam 4th Street NGO Colony, Nanganallur, Chennai 600 061
COMPREHENSIVE MAINTENANCE AND REPAIR/ REPLACEMENT OF SPARES OF LIFTS INSTALLED AT CGRA PHASE-II, MEENAMBAKKAM AREA UNDER GE (I) (CG) CHENNAI
2025_MES_745774_2
8265/E8
Open Tender
Civil Works
Item Rate
244 days
CHENNAI
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer (I) (CG)
₹76,000
Yes
8 Apr 2026
9 Feb 2026
23 Feb 2026
9 Feb 2026
21 Feb 2026
16 Feb 2026
NOTE FOR ITEMS NO.1.00 & 2.00: FORTNIGHTLY MAINTENANCE/CHECKS (a) Check the alignment and operation of the Door operating mechanism at all landings (b) Check the action of the brake with lift in Operation (c) Check shoes, pulleys and lubricate (d) Check oil level and oil leakage in the gear
MONTHLY MAINTENANCE/CHECKS (a) Check the position of the operating cum in relation to the landing door and door locks (b) Clean lubricate pivot point and wherever requires (c) Lubricate the brake pin (d) Check suspension of ropes and anchorage and lubricate (e) Check over speed of governor and lubricate the required part (f) Make full ascent and decent to assess the quality of theride at all points
QUARTERLY MAINTENANCE/CHECKS (a) CAR (i) Clean light fixtures (ii) Check retiring cam device chain, dash pots, commutator brush cams, divots, fastenings. (iii) Check emergency switch/battery & Alarm bell (iv) Check safety points, set, screws, switches (b) Check trailing cables for evidence of chaffing orother constructions in the lift well check anchorages. (c) Inspect at every landing, landing doors, tracks,guidesand locks, fasteners and clean and lubricate them.4. Check function box for loose connections and also check mainline switch fuses for heating. (d) Check car and counter weight guides and shoes. (e) Check whether guide rail surface is smooth and clean. Also check the guide shoes for excessive wear & tear (f) Check and lubricate all bearings & gear box (g) Motor, Generators, Evictor : Clean all commentators and renew or reset brushes if necessary. (h) Ropes : Check all fastening inspect all rope for wear and lubricants (j) Leveling : Check leveling operation and switches
(g) Run the machine in both direction and check sign of excessive play or back lash in gear. Check the overheatingor excessive bearing noise (h) Check oil level and oil leakage in the gear (j) In DC motors and MG sets check commutation for fitting or wear and for signs of undue sparking or brush chatter keeps them clean (k) Check brushes and ensure that spring for adjusting Brush pressure is adjusted to give enough pressure on the brushes. (l) Check the conditions of linings and couplings (m) Check the tightness of the coupling keys
ANNUAL MAINTENANCE/CHECKS (a) MACHINE ROOM (i) Examine all main switches for positive make and break of contacts. Check for loose connections (ii) Clean machine room and ensure proper earthing of motors, controllers, bed plates.
(b) CONTROL BOARD (i) Keeps the controller clean and free from dust (ii) Lubricate all moving parts and check for loose connection if any (iii) Check gap between armature and housing plate (iv) Check and clean all contact (v) Check transformer connections are tight or not (vi) Check resistors, capacitors and rectifiers. (vii) Check fuse ratings etc
(c) MACHINE UNIT (i) Check for any abnormality such as vibrations noisetemperature, alignment and check all grease cups and refill if required (ii) Check all bed plate and ensure that all bolts are tight and of the diverting pulley plates and rigid. (iii) Check motor/MG set/DC motor & Techno generatorfor oil levels up to the given marking in case of oil leakage change the oil seal and check the axial play rigidly and belt tension. (iv) GEAR UNIT : Overheating and leaking to be checked for gear box and must be filled with oil (ENKLO-320) (v) BREAK DRUM & COUPLINGS : Check that bolt, nuts, rubberbushes are in appropriate position(if the rubber bushesare found replace them) (vi) Check the running sound, if any unusual running sound develops rectify. (vii) Check that the diverter pulley and shaft (viii) Shift of fruition sleeve on shaft should be checked andrectified immediately.
(d) BRAKE (i) Ensure that the brake liners are not worn out (ii) Adjust the jaws such that it will not rest on the brake drum while the lift is running. Ensure that both the jaws have same clearances from brake drum. (iii) Adjust the brake tension to compromise betweenthe jerk and lift levels. (iv) Check the electrical connections are firm or not (e) MAIN LIMIT SWITCH (i) Set the top and bottom striker plate (ii) Apply the petroleum jelly on the knife edge contacts
Additional Note for item No 1.00 & 2.00 : (i) The contractor shall mandatorily to submit valid Letter of Authorization/Accreditation issued by the OEM for manitenance and repairs of the above work at site. (ii) The spares/electrical items as listed in Sch 'A' Part II will be used whenever required only and measured and paid separately under respective items. (iii) The rate is inclusive of all items as required at site except those items as given in Sch 'A' Part II to keep the lift operational round the clock including cleaning and greasing all moving parts on monthly basis complete all as specified and as directed by Engineer-in-Charge. (iv) If spare parts of original make is not available in market necessary suitable spare equivalent to existing lift part as approved by Engr-in-charge shall be used in the work so that to run the lift with smooth functioning. (v) Cost of renewal of lift license from Lift inspector, Govt. of Tamil Nadu is demed to be included in the qruoted rate against Sl No 1 to 2.
(vi) Quoted rate includes the testing of all the lifts by licensed Lift Inspector of Tamil Nadu twice in contract period for safety if required / asked by GE. Certificate issued by the licensed lift inspector shall be submitted to Engineer-in-charge. (vii) In case of any of the lift/lifts is/are not working for more than 24 hours but less than 10 days, Recovery will be affected at the rate of Rs.2,000/- per lift per day and Rs.3,000/- per lift per day after 10 days. (viii) The above lifts shall be repaired through OEM (Original Equipment manufacturer) or through their nearest authorised/ accredited agency service personel only. The bidder shall submit and uploading MoU from the OEM of lift or their authorised/ accredited agency at time of uploading of tender. (ix) Contractor should submit all valid docucments before the opneing of tehcnicial bid. (x) Testing cerfificte of each lift duly tested by Electrical Lift Inspector shall be provided by the contractor.
SPARE PARTS OF LIFTS
Supply only Main controller transformer primary 415V AC secondary - 24/110/130/230/270v AC. Make:SSPM or equivalent
Supply only Floor oscillator relay optical type working on 12/24 Volt DC.
Supply only Main contactor with coil, 60 Amp, Power contactor with 2 NO + 2NC aux. Contacts and with 230 V AC/DC Coil . Make : C&S, ABB.
Supply only Power contactor 32 Amps with 24/48 V AC / DC coil. Power contactor, 32 Amps with 02 No + 2 NC. Aux contacts with 230 V AC/110VDC complete all as directed. Make : C&S, ABB.
Supply only Digital lift cabin position indicator 1 digit vertical one segment card. Make: IES
Supply only Lift cabin coaxial fan 300 mm 1000 RPM.
Supply only Nylon roller for lift car door and landing door 35X40 mm. Make IES
Supply only COP digital position indicator with FL/OL card for lift cabin. Make IES
Supply only Lift cabin / Landing illuminated push button working
Supply only Six relay card for lift control panel. Make : IES
Supply only Two relay card for lift control panel. Make : IES
Supply only Three changeover relay 24V DC. Make : PLA
Supply only Two changeover relay 24V DC. Make : PLA
Supply only Trailing cable 10 core x 0.75 Sqmm, 100meter Coil.
Supply only Full length Infrared sensor 04 beams for car door including transmitter, receiver and control unit.
Supply only Maintenance free sealed battery 12V 7AH. Make : Exide/ Amaron/Amco
Supply only Lift landing door rope for 800mm center opening door mechanism. Make : IES.
Supply only car door operator belt for 800mm center opening door mechanism. Make : IES.
stage.html
html • 0.06 MB
technical_842246.pdf
techsummary_842246.pdf
finance_842246.pdf
BOQ Comparative Chart
xlsx
finsummary_842246.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
8265TENDER.pdf
Tender Documents • 0.69 MB
BOQ_842246.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .