| 1 | Supply of 5 Star rating inverter split AC of 1.5 TR Min. ISEER 5.0 | Supply of 5 Star rating fully inverter split type Air conditioner of 1.5 TR Minimum ISEER 5.0 capacity with adjustable mode 0.7,1,1.2,1.5 different cooling capacities for different cooling needs, fitted with rotary scroll compressor of min 05 years warranty, having copper condenser coil, operating for Refrigerant R32 eco friendly green gas and indoor unit suitable for wall mounting operation with cordless LCD or LED Remote, Auto restart operation, connecting copper refrigerant pipes with suitable nitrile insulation including charging of suitable refrigerant gas, 4C x 4 Sq.mm copper cable, drain pipe up to 3Mtr. and suitable for operating on 230V plus or minus 10%, 50Hz, Single Phase, AC , control wiring, thermostat, washable synthetic air filter etc. complete as capable of performing Cooling, stablizer free operation etc. meeting the technical specifications and make as per the list of preferred make. | 8 | Each | piyushmeshram | 45 |
| 2 | Supply of 5 Star rating inverter split AC of 2.0 TR Min. ISEER 5.0 | Supply of 5 Star rating fully inverter split type Air conditioner of 2.0 TR Minimum ISEER 5.0 capacity with adjustable mode different cooling capacities for different cooling needs, fitted with rotary or scroll compressor of min 05 years warranty, having copper condenser coil, operating for Refrigerant R32 eco riendly green gas and indoor unit suitable for wall mounting operation with cordless LCD or LED Remote, Auto restart operation, connecting copper refrigerant pipes with suitable nitrile insulation including charging of suitable refrigerant gas, 4C x 4 Sq.mm copper cable, drain pipe up to 3Mtr. and suitable for operating on 230V plus or minus 10%, 50Hz, Single Phase, AC , control wiring, thermostat, washable synthetic air filter etc. complete as capable of performing Cooling, stablizer free operation etc. meeting the technical specifications and make as per the list of preferred make. | 2 | Each | piyushmeshram | 45 |
| 3 | Supply of energy efficient 3.0 TR Cassette type Air conditioner | Supply of energy efficient 3.0 TR Cassette type Air conditioner fitted with suitable compressor operating on green refrigerant gas R32 or R410A as suitable for ceiling mounting confirming to relevent IS specifications operating on 3 phase 415 V 50 Hz AC supply including standard copper piping as per manufacture design and power cables including drain pipe and suitable MS supporting stand for outdoor unit etc. as required. | 6 | Each | piyushmeshram | 45 |
| 4 | Installation, Testing and Commissioning of split type Air conditioner upto and including upto 3.0 TR | Installation, Testing and Commissioning of split type Air conditioner of upto and including upto 3.0 TR capacity and fixing of refrigerant copper piping of suitable size for both suction and discharge along with suitable nitrile or thermal Insulation and Electrical Cable 4C x 4 Sq.mm of size having suitable size of copper conductor for connection from indoor to outdoor unit including charging of suitable refrigerant gas, providing mounting stand for out door unit and all suitable necessary accessories complete as per site requirement. | 17 | Job | piyushmeshram | 45 |
| 5 | Supply of Extra Refrigerant copper piping for 1.5TR or 2.0 or 3.0 TR A.C | Supply of Extra Refrigerant copper piping for 1.5TR or 2.0 TR or 3.0 TR A.C of suitable size for both suction and discharge along with suitable thermal Insulation and Electrical Cable of suitable size copper conductor for connection from indoor to outdoor unit and suitable necessary accessories for connection complete as required. One length of suction piping , one length of discharge piping and one length of copper wire shall be measured one meter for this item. | 50 | Meter | piyushmeshram | 45 |
| 6 | Supply and fixing of hard UPVC drain pipe of 25 mm dia | Supply and fixing of hard UPVC drain pipe of 25 mm dia connection from indoor to outside of wall including bends, suitable insulation , U straps , clamps and necessary accessories for connection etc. complete as required. | 105 | Meter | piyushmeshram | 45 |
| 7 | Dismantling of existing 1.5 TR or 2.0 TR or 3.0 TR Capacity split Air Conditioning | Dismantling of existing 1.5 TR,2.0 TR,3.0 TR Capacity split Air Conditioning units indoor and outdoor with suction and discharge pipeline, stand, wires etc from different locations at Jalgaon Airport and shifting to AAI, Jalgaon Store i/c transportation charges etc. complete as required. | 17 | Job | piyushmeshram | 45 |
| 8 | Supply, Installation, Testing and Commissioning of 50LPH industrial or commercial type Reverse Osmosis water Purifier | Supply, Installation, Testing and Commissioning of 50LPH industrial or commercial type Reverse Osmosis water Purifier having filters like Particulate Filter, Membrane Life Enhance Filter, Pre Carbon Block Filter, Sediment Filter, Reverse Osmosis Membrane Filter, Post Carbon Filter With RO Membrane Auto Flushing and purified water production capacity not less than 50 LPH. ,Make. ION Exchange Zero B, Model- ECO SMART RO 50 LPH or its equivalent as approved by Engineer -In - Charge. | 1 | Job | piyushmeshram | 45 |
| 9 | Supplying and fixing 20amps , 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps C curve, SP, MCB, in sheet steel enclosure | Supplying and fixing 20amps , 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. | 5 | Job | piyushmeshram | 45 |
| 10 | Supply and fixing of 75mm dia medium class PVC pipe | Supply and fixing of 75mm dia medium class PVC pipe for covering refrigerant copper piping for both suction , discharge and Electrical Cable with suitable necessary accessories for pipe connection complete as required. | 80 | Meter | piyushmeshram | 45 |