Tender Value
₹66.9 L
EMD Value
₹1.3 L
Closing Date
28 May 2026, 12:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
WORKS
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Important Note :- For Detail Regarding Financial Eligibility Criteria, Please visit Para No 2.2 of INSTRUCTIONS TO TENDERER & CONDITIONS OF CONTRACT of Approved Tender Document.
Technical Eligibility Criteria: The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of the tender. Note:-Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. The similar work mean having experience of the following types of works. "Repair/Rehabilitation/Overhauling/ AMC/ Supply, erection, testing and commissioning of Central AC unit/ Window AC /Package AC units / Air conditioning duct / Split type AC units / Water coolers etc." Important Note:- For Detail Regarding Technical Eligibility Criteria, Please visit Para No 2.2 of INSTRUCTIONS TO TENDERER & CONDITIONS OF CONTRACT of Approved Tender Document.
10 conditions · 6 needing a document upload
As mentioned in the Tender Document No. PUNE_ELECT_G_26_08
Copy of PAN Card
Copy of GST registration certificate
Tender form (First Sheet) as per Annexure-I
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
As mentioned in the Tender Document No. PUNE_ELECT_G_26_08
Tender document with Guidelines, Special conditions & Scope of work and GCC April 2022 with all advance correction slips are attached with tender
Repair and Maintenance of Air Conditioners, Water Coolers, and Refrigerators at Various Locations in Pune Division for a Period of 3 Years.
PUNE_ELECT_G_26_08
PUNE_ELECT_G_26_08
Open
Works - General
36 Months
Pune, Maharashtra
₹0
₹1.3 L
28 May 2026
4 May 2026
14 May 2026
95 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 66,93,304.03 | ||
| — | Item Breakup for | details. | — | ||
| Cleaning of filters, condenser coil, evaporator coil, checking of electrical connection, checking of working etc. of all types and capacity of AC unit once in two months. | — | — | — | 21,70,692.18 | |
| — | Item Breakup for | details. | — | ||
| Cleaning of water tank, condenser coil, checking of electrical connection, checking of working, replacement of filter provided by Railway etc. of all types and capacity of Water cooler once in two months. | — | — | — | 2,49,766.74 | |
| — | Item Breakup for | details. | — | ||
| Cleaning of refrigerator, condenser coil, checking electrical connection, checking of working etc. of all types and capacity of Refrigerator once in Two months. | — | — | — | 6,04,331.46 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective compressor by new compressor of 1.5Tr capacity Window/Split AC with gas charging and other required accessories and activities. | — | — | — | 3,89,762.91 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective compressor by new compressor of 2/2.5Tr capacity with gas charging and other required accessories and activities. | — | — | — | 54,467.28 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective compressor by new compressor of 3/3.5/4 Tr capacity with gas charging and other required accessories and activities. | — | — | — | 1,57,416.14 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective compressor by new compressor of all type & capacity water coolers with gas charging and other required accessories and activities. | — | — | — | 2,61,985.2 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective compressor by new compressor of all type & capacity Refrigerators with gas charging and other required accessories and activities. | — | — | — | 46,604.64 | |
| — | Item Breakup for | details. | — | ||
| Nitrogen flushing, leakage testing and repairing by brazing ,vaccuminazing and refrigerant gas charging of all type & capacity AC, water coolers and refrigerator. | — | — | — | 4,35,501.92 | |
| — | Item Breakup for | details. | — | ||
| Rewinding of defective condenser fan motors of all type and capacity of AC & water cooler. | — | — | — | 43,733.8 | |
| — | Item Breakup for | details. | — | ||
| Rewinding of defective evaporator blower fan motors of all type and capacity of AC. | — | — | — | 31,762.8 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective condenser fan motors of all type and capacity of AC & water cooler. | — | — | — | 49,697.18 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective evaporator blower fan motors of all type and capacity of AC. | — | — | — | 48,358.66 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective aluminum condenser coil by new copper condenser coil for split AC units of 1.5 Tr capacity. | — | — | — | 74,753.7 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective aluminum condenser coil by new copper condenser coil for split AC units of 2/2.5 Tr capacity. | — | — | — | 27,791.22 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective aluminum condenser coil by new copper condenser coil for split AC units of 3/3.5/4 Tr capacity. | — | — | — | 25,938.4 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective capacitor P2 type 36 45 60 80 150 180 210 MFD | — | — | — | 13,687.54 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective capacitor P2 type 2.5 to 10 MFD. | — | — | — | 9,573.04 | |
| — | Item Breakup for | details. | — | ||
| Repair /replacement of control PCB all type and capacity of AC | — | — | — | 52,336.5 | |
| — | Item Breakup for | details. | — | ||
| Supply of required refrigerant gas required for AC, water cooler and refrigerator. | — | — | — | 4,59,344.96 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective swing motor by new one for all types of AC's | — | — | — | 38,115.22 | |
| — | Item Breakup for | details. | — | ||
| Replacement of thermal relay of all types of AC, water cooler and refrigerator. | — | — | — | 41,049.25 | |
| — | Item Breakup for | details. | — | ||
| Replacement of defective remote for all type of SAC | — | — | — | 53,419.12 | |
| — | Item Breakup for | details. | — | ||
| Provision of core cutting | — | — | — | 7,750.85 | |
| — | Item Breakup for | details. | — | ||
| Dismantling the existing air conditioner of all type and capacity upto 3 TR safely without any damages and making the site clear as per direction of engineer in charge | — | — | — | 21,730.68 | |
| — | Item Breakup for | details. | — | ||
| Erection of 1.5/2 Tr split AC | — | — | — | 59,917.48 | |
| — | Item Breakup for | details. | — | ||
| Erection of 3Tr split AC | — | — | — | 11,780.35 | |
| — | Item Breakup for | details. | — | ||
| Supply fabrication and erection of MS items (channel angle flat nut bolt etc.) | — | — | — | 11,734 | |
| — | Item Breakup for | details. | — | ||
| Replacement of internal wiring by new copper wiring of AC unit with proper size lug. | — | — | — | 32,583.6 | |
| — | Item Breakup for | details. | — | ||
| Brick work | — | — | — | 24,998 | |
| — | Item Breakup for | details. | — | ||
| Plastering of brick work | — | — | — | 1,195.52 | |
| — | Item Breakup for | details. | — | ||
| Replacement of both side trench flexible pipe for water cooler | — | — | — | 9,817.68 | |
| — | Item Breakup for | details. | — | ||
| Replacement of water stainless steel tap for water cooler | — | — | — | 9,471.82 | |
| — | Item Breakup for | details. | — | ||
| Replacement of float valve for water cooler of suitable size | — | — | — | 40,779 | |
| — | Item Breakup for | details. | — | ||
| Replacement of drain pipe for water cooler and AC | — | — | — | 7,096.64 | |
| — | Item Breakup for | details. | — | ||
| Replacement of flayer nut for all type of AC units | — | — | — | 626.25 | |
| — | Item Breakup for | details. | — | ||
| Replacement of dead cap for all type of AC units | — | — | — | 1,200.6 | |
| — | Item Breakup for | details. | — | ||
| Replacement of NRV for all type of AC units | — | — | — | 459.36 | |
| — | Item Breakup for | details. | — | ||
| Replacement of inlet outlet brass valve for AC | — | — | — | 4,384.38 | |
| — | Item Breakup for | details. | — | ||
| Replacement of electric power contactor | — | — | — | 10,619.4 | |
| — | Item Breakup for | details. | — | ||
| Replacement of unserviceable PCB for indoor type inverter A/C unit upto 2 TR capacity | — | — | — | 1,55,470.8 | |
| — | Item Breakup for | details. | — | ||
| Replacement of unserviceable PCB for outdoor type inverter A/C unit upto 2 TR capacity | — | — | — | 2,60,615.76 | |
| — | Item Breakup for | details. | — | ||
| Replacement of water filter of water purifier | — | — | — | 22,186.4 | |
| — | Item Breakup for | details. | — | ||
| Replacement of carbon filter of water purifier | — | — | — | 13,222.2 | |
| — | Item Breakup for | details. | — | ||
| Supply and erection of 2.5 sqmm 3 core cable | — | — | — | 1,40,130 | |
| — | Item Breakup for | details. | — | ||
| Supply and erection of Refrigerant Piping for airconditioning" Supply & Installation of interconnecting suitable sizes of one end expanded refrigerant copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) & 19mm thick (pipe size above 19.1mm dia) closed cell electrometric nitrile rubber tubular insulation with alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification at Tech Spec-I. 9.5 mm dia with 13mm thick nitrile rubber insulation: 18G | — | — | — | 2,93,480 | |
| — | Item Breakup for | details. | — | ||
| Supply and erection of Refrigerant Piping for airconditioning" Supply& Installation of interconnecting suitable sizes of oneend expanded refrigerant copper copper pipe work, insulated with 13mm thick (pipe size upto 19.1mm dia) &19mm thick (pipe size above 19.1mm dia) closed alluminium foil between each set of indoor & outdoor units with outer mechanical protection for all exposed pipes as per specification. All piping inside the room shall properly run in MS/GI supports and hangers etc. as reqd. and perforated cable tray as mentioned below for exposed pipes and in the shaft and confirming to specification at Tech Spec-I. 12.7 mm dia with 13mm thick nitrile rubber insulation: 18 G | — | — | — | 2,11,963.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ApprovedTenderDocumentPUNE_ELECT_G_26_08.pdf Approved TB PUNE ELECT G 26 08
ATTACHMENT
ANNEXURE-I.pdf
ATTACHMENT
ANNEXUREVVA.pdf
ATTACHMENT
ANNEXURE-VIA.pdf
ATTACHMENT
ANNEXURE-VIB.pdf
ATTACHMENT
GCCApril2022withCorrectionslips1to11.pdf
ATTACHMENT
ApprovedTenderDocumentPUNE_ELECT_G_26_08.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .