Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC | ₹39.3 L Quoted ₹40.0 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹41.2 L+₹1.2 L (3.12%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | ₹41.2 L+₹1.2 L (3.12%) | L2 | Rejected-Finance NOT THE LOWEST BIDDER |
| 3 | L3₹41.6 L+₹1.6 L (4.00%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | ₹41.6 L+₹1.6 L (4.00%) | L3 | Rejected-Finance NOT THE LOWEST BIDDER |
| 4 | Rejected-Technical GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | - | - | Rejected-Technical REJECT DUE TO NOT HAVE A PROPER CATEGORY |
| 5 | Rejected-Technical | - | - | Rejected-Technical REJECT DUE TO ESIC NOT SUBMITTED |
| Sl No | Description | Qty | Unit | Shree Trilok Electric Corporation L3 | STANDARD ELECTRIC WINDERS L2 | FREEZCON L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing of service for Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for floor mounted Package type water cooled AC plant of capacity 3 x5 TR by cleaning of airfilters,cleaning of all air control equipment for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of minor control wiring, greasing of blower motor,checking of all safety measures, topping of required refrigerant gas and compressor oil as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results, in presence of Engineer-in-Charge complete all as specified and directed.[Package type air cooled AC plant of capacity 3 x 5 TR, Make - M/s Batliboy Ltd installed at 162 MH]. | 11 | Each Job per month | 21,230 ₹2,33,530 | 20,970 ₹2,30,670 | 20,500 ₹2,25,500 Lowest |
| 2.00 | Providing of service for Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Central air cooled AC plant of capacity 3x28TR, by cleaning of airfilters, cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring,greasing of blower motor, checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results,in presence of Engineer-in-Charge, complete all as specified and directed. [Central AC plant of capacity 3x28 TR,Make- M/s Batliboy Ltd (installed at 162 MH) | 11 | Each Job per month | 35,100 ₹3,86,100 | 34,675 ₹3,81,425 | 33,900 ₹3,72,900 Lowest |
| 3.00 | M & L for servicing of weatherproof FRP type crossflow cooling tower of Paharpur Make for 56 TR Central AC plant having three phase 415 volts belt drive fan motor assembly by dismentaling of fan and suction guard, drift eliminnator & louvres, draing of existing water from basins , removing of scales and proper cleaning of Nozzle, louvers assembly set, basins tray and outgoing filter by suitable chemical, toping up of bearing oil, checking and tightning/adjustment of belt drive as per OEM recomendation, including replacing of waer and tear nut bolts and minor parts all as specified and as directed by Engr in charge. | 11 | Each Job | 17,700 ₹1,94,700 | 17,490 ₹1,92,390 | 17,100 ₹1,88,100 Lowest |
| 4.00 | Same as above item but for 10 TR package type AC plant & motor power rating three phase 415 volts as specified and as directed by Engr in charge. | 11 | Each Job | 14,100 ₹1,55,100 Lowest | 14,480 ₹1,59,280 | 14,150 ₹1,55,650 |
| 5.00 | De-scaling of water cooled condenser unit of 28 TR capacity by non-chemical approved water treatment system after opening end covers and removing scales using nylon brush and re-assembling the same by replacing rubber gasket and washing by circulating fresh water complete all as specified and directed. | 11 | Each Job | 19,680 ₹2,16,480 | 19,440 ₹2,13,840 | 19,000 ₹2,09,000 Lowest |
| 6.00 | De-scaling of water cooled condenser unit of 5 TR capacity by non-chemical approved water treatment system after opening end covers and removing scales using nylon brush and re-assembling the same by replacing rubber gasket and washing by circulating fresh water complete all as specified and directed. | 11 | Each Job | 9,740 ₹1,07,140 | 9,620 ₹1,05,820 | 9,400 ₹1,03,400 Lowest |
| 7.00 | Cleaning of cooling coil of AHU, capacity 56 TR including flushing with suitable high pressure gas and chemicals as approved/recommended by the manufacturer complete all as directed. | 11 | Each Job | 12,500 ₹1,37,500 | 12,280 ₹1,35,080 Lowest | 12,300 ₹1,35,300 |
| 8.00 | Cleaning of cooling coil of AHU, capacity 5 TR including flushing with suitable high pressure gas and chemicals as approved/recommended by the manufacturer complete all as directed. | 11 | Each Job | 7,300 ₹80,300 | 7,200 ₹79,200 | 7,000 ₹77,000 Lowest |
| 9.00 | Supply only "Carbon brush for 40 HP" for induction motor. | 18 | Each | 920 ₹16,560 | 905 ₹16,290 Lowest | 910 ₹16,380 |
| 10.00 | M & L for rewinding of burnt out 5 TR blower motor, model SV-505 M complete all as specified and directed. | 1 | Each | 12,950 ₹12,950 | 12,790 ₹12,790 | 12,500 ₹12,500 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Apr 2026, 6:00 pmClosed
CWE DINJAN
COMMANDER WORKS ENGINEER DINJAN
REPAIR MAINT OF CENTRAL AC PLANT AND PACKAGE AC PLANT WITH ITS ALLIED WORKS AND REPAIR MAINT OF VRF ACs OTHER VOLTAGE STABLIZER INSTALLED AT SIGNAL CENTRE UNDER GE DINJAN
2026_MES_756636_1
84547/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE DINJAN
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
GE DINJAN
₹80,000
Yes
18 May 2026
17 Mar 2026
13 Apr 2026
17 Mar 2026
6 Apr 2026
31 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing of service for Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations for floor mounted Package type water cooled AC plant of capacity 3 x5 TR by cleaning of airfilters,cleaning of all air control equipment for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of minor control wiring, greasing of blower motor,checking of all safety measures, topping of required refrigerant gas and compressor oil as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results, in presence of Engineer-in-Charge complete all as specified and directed.[Package type air cooled AC plant of capacity 3 x 5 TR, Make - M/s Batliboy Ltd installed at 162 MH]. | 11 | Each Job per month | - | - |
| 2 | Providing of service for Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Central air cooled AC plant of capacity 3x28TR, by cleaning of airfilters, cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring,greasing of blower motor, checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results,in presence of Engineer-in-Charge, complete all as specified and directed. [Central AC plant of capacity 3x28 TR,Make- M/s Batliboy Ltd (installed at 162 MH) | 11 | Each Job per month | - | - |
| 3 | M & L for servicing of weatherproof FRP type crossflow cooling tower of Paharpur Make for 56 TR Central AC plant having three phase 415 volts belt drive fan motor assembly by dismentaling of fan and suction guard, drift eliminnator & louvres, draing of existing water from basins , removing of scales and proper cleaning of Nozzle, louvers assembly set, basins tray and outgoing filter by suitable chemical, toping up of bearing oil, checking and tightning/adjustment of belt drive as per OEM recomendation, including replacing of waer and tear nut bolts and minor parts all as specified and as directed by Engr in charge. | 11 | Each Job | - | - |
| 4 | Same as above item but for 10 TR package type AC plant & motor power rating three phase 415 volts as specified and as directed by Engr in charge. | 11 | Each Job | - | - |
| 5 | De-scaling of water cooled condenser unit of 28 TR capacity by non-chemical approved water treatment system after opening end covers and removing scales using nylon brush and re-assembling the same by replacing rubber gasket and washing by circulating fresh water complete all as specified and directed. | 11 | Each Job | - | - |
| 6 | De-scaling of water cooled condenser unit of 5 TR capacity by non-chemical approved water treatment system after opening end covers and removing scales using nylon brush and re-assembling the same by replacing rubber gasket and washing by circulating fresh water complete all as specified and directed. | 11 | Each Job | - | - |
| 7 | Cleaning of cooling coil of AHU, capacity 56 TR including flushing with suitable high pressure gas and chemicals as approved/recommended by the manufacturer complete all as directed. | 11 | Each Job | - | - |
| 8 | Cleaning of cooling coil of AHU, capacity 5 TR including flushing with suitable high pressure gas and chemicals as approved/recommended by the manufacturer complete all as directed. | 11 | Each Job | - | - |
| 9 | Supply only "Carbon brush for 40 HP" for induction motor. | 18 | Each | - | - |
| 10 | M & L for rewinding of burnt out 5 TR blower motor, model SV-505 M complete all as specified and directed. | 1 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderDocuments.pdf
Tender Documents • 1.05 MB
BOQ_847552.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .