Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.2 L+₹1.3 L (8.07%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹19.5 L+₹3.6 L (22.3%)Rejected-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹21.1 L+₹5.2 L (32.5%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
29 Sept 2021, 6:00 pmClosed
SHUBHAM PRAKASH
GE NORTH UDHAMPUR
GE U(N) 52 2021 22 REPAIR MAINTENANCE OVERHAULING OF CEILING FANS EXHAUST FANS BRACKET WALL FANS AND GEYSER OF ANY DESCRIPTION INCLUDING REWINDING OF THE SAME FITTED IN THE BLDG IN THE AREA UNDER GE (NORTH) UDHAMPUR
2021_MES_471834_1
GE/U(N)-52/2021-22
Open Tender
Civil Works
Item Rate
330 days
GE NORTH UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NORTH UDHAMPUR
₹40,000
Yes
28 Oct 2021
31 Aug 2021
1 Oct 2021
31 Aug 2021
29 Sept 2021
14 Sept 2021
Amount
Opening cutting and taking out old burned/damaged winding of following fans and rewinding of fans with super enameled copper wire of existing gauge and capacity including all insulating materials refilling of metal in shaft, oiling with fresh oil, greasing with best quality grease, varnishing with best quality air dry varnish, cleaning of serviceable ball bearing/bush, re-assembling of fans and testing to the entire satisfaction of Engineer-in-Charge complete. (Ball bearing/bush if required new will be measured and paid separately as supply only). Note : (i) One electrician and one helper will report daily to JE E/M for repair to Ceiling/exhaust fan except sunday/holiday for entire contract period. (ii) The contractor should repair/replace if any spares damaged with in its warranty period (6 months) with out any extra cost. (a) Ceiling fan 1200 mm sweep any make to the entire satisfaction of Engineer-in-Charge
(b) All as per Si No 1 above but ceiling fan 1400 mm sweep any make to the entire satisfaction of Engineer-in-Charge
(c ) All as per Si No 1 above but exhaust fan 350/400 mm sweep any make to the entire satisfaction of Engineer-in-Charge
(d) All as per Si No 1 above but exhaust fan 250/300 mm sweep any make to the entire satisfaction of Engineer-in-Charge
(e) All as per Si No 1 above but wall mounting fan any type ,capacityand any Make to the entire satisfaction of Engineer-in-Charge
Supply only following new parts for fans & air circulators to the entire satisfaction of Engineer-in-Charge Ball bearing for ceiling fan 1200/1400 mm sweep to the entire satisfaction of Engineer-in-Charge
Ball bearing for exhaust fan 350/400 mm sweep to the entire satisfaction of Engineer-in-Charge
Ball bearing for exhaust fan250/300 mm sweep to the entire satisfaction of Engineer-in-Charge
Ball bearing for wall mounting fan any type to the entire satisfaction of Engineer-in-Charge
Mild steel Nut bolts off sizes to the entire satisfaction of Engineer-in-Charge
Rubber real with suitable size of clamps, nuts, bolts & split pin to the entire satisfaction of Engineer-in-Charge
Condenser/Capacitor clip any size to the entire satisfaction of Engineer-in-Charge
S&F ceiling fan regulator electronic step type including taking down old/unsv item to the entire satisfaction of Engineer-in-Charge
Taking out unserviceable condenser/capacitor from the fans and new capacitor 230 volts, 50 HZs, 2.5 MFD (dry type) suitable for ceiling fan and connect the same in circuit and testing complete to the entire satisfaction of Engineer-in-Charge
All as per item No14 above but new capacitor 3.15 MFD to the entire satisfaction of Engineer-in-Charge
All as per item No 14 above but new capacitor 4 MFD suitable for exhaust fan to the entire satisfaction of Engineer-in-Charge
All as per item No 14 above but new capacitor 6 MFD to the entire satisfaction of Engineer-in-Charge
M&L for carrying out remetalling in worn out shaft, cutting and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the satifaction engineer in charge to ensure smooth and noise free operation to the entire satisfaction of Engineer-in-Charge (bearing shall be measured and paid seperately )
Taking down carefully exhaust fan any sweep and make, dismantling of blades, frame and opening and examining fan motor, cleaning of dust/.dirt of fan, cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively, including applying synthetic enamel paint to achieve glossy finish white/coloured as directed by Engineer-in-Charge and marking MES No with black paint and reassembling of complete fan and re-fixing in its original location making connection and testing to the entire satisfaction of Engineer-in-Charge complete. Note:Ball bearing, bush and PVC insulated cable if required will be measured and paid separately as supply only
Supply only PVC insulated copper wire size 23/0.0076 to the entire satisfaction of Engineer-in-Charge
Taking down carefully ceiling fan any type, sweep and make for overhauling incl dismantling of blade frame and opening and examining motor cleaning of dust/dirt of fan cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively and reassembling of complete fan after re-fixing parts in its original location and hanging connecting and testing ceiling fan for smooth functioning incl replacement of rubber real insulator and painting with one coat of synthetic enamel paint with spray painting machine & marking MES No. with black paint complete to the entire satisfaction of Engineer-in-Charge .Note : Bearing, bush, condenser and insulated cable if required will be measured and paid separately
Supply only Down rod for ceiling fan made out of 15mm bore medium grade G.I. Pipe including cutting, threading, drilling holes and making grooves,and spraying paint with two coats of synthetic white paint fixed in repairs complete of following lengths:- (a). 24" long/ 60cm long
(b) 48" long/ 120cm long
Fixing only exhaust fans after repair/rewinding and connectig up including provision of cable from ceiling rose/connector to fan to the entire satisfaction of Engineer-in-Charge
Fixing only ceiling fans after repair/rewinding in repair and connectig up including provision of cable from ceiling rose/connector to fan to the entire satisfaction of Engineer-in-Charge (Fans repair under si no 1 to 5)
S&F in repair/replacement of ceilling fan blade of 1200/1400 mm sweep as per sample complete all as specified and directed.
Supply and fixing 'S' type hook made of 12 mm dia MS round bar/MS flat strip 40x4 mm of appropriate size after taking out old rusted wornout hook to the entire satisfaction of Engineer-in-Charge
Disconnecting all water and electric connections of geysers and taking down carefully installed storage type electric geysers of any capacity of any make/type/size (horizontal/vertical) lowering and setting aside opening geysers examining and checking thoroughly for requisite repair/ replacement of defective/worn-out/ unserviceable components/parts materials including preparing inventory for each geyser separately in presence of Engineer-in-Charge and removing all scale and dirt de-scaling of deposited in inner copper tank and outer tank and heating elements by HCL or aqua clear pedilite solution, thermostat, indicator lamp, assemble checking electrical connection, stopping of minor leaking by soldering/brazing of the inner copper tank and replacement of defective worn out unserviceable components/parts (new components/parts shall be measured and paid separately as supply only herein after) & re-fixing geyser in its original location including hoisting, connecting to water & electric connection and testing for proper functioning of geysers including earthing to the entire satisfaction of the Engineer-in-Charge.Note:The replacement of heating element, fusible plug, indicator lamp, thermostat, CP connection and inner tank and outer tank will be done only when it will be found unserviceable/un-repairable after de-scaling the same to the entire satisfaction of Engineer-in-Charge /after approval of engineer in charge
Supply only following parts/components of geysers of suitable capacity size, shape as per existing make conforming to IS complete. (a) Base cover plate suitable for any capacity geyser complete all as specified and directed
(b) GI fastner bolts including nuts washers off sizes suitable forfixing of any capacity geyser as required at site to the entire satisfaction of Engineer-in-Charge
(c ) Stain less steel Inner tank suitable for geyser of 25 ltr capacity corrosion resistance as per existing make to the entire satisfaction of Engineer-in-Charge
(d) Stain less steel Inner tank suitable for geyser of 50 ltr capacity as per existing make to the entire satisfaction of Engineer-in-Charge
(e) Glass wool superior quality suitable for any capacity geysers all as specified and directed.
(f)Rubber ring gasket superior/made out rubber having holes to suit the hole of base plate suitable for any capacity geysers to the entire satisfaction of Engineer-in-Charge
(g)PVC copper cable flexible 3 core round heavy duty size 40/0.0076 suitable for geyser any capacity to the entire satisfaction of Engineer-in-Charge
(h)Fiber reinforced PVC nylon pipe heavy duty size 450 mm long 15mm bore with brass coupling chromium plated with rubber washers at both ends as per IS.
(j)Heating element 2 KW any type for geyser any capacity to the entire satisfaction of Engineer-in-Charge
(k)Heating element 1.5 KW any type for geyser any capacity to the entire satisfaction of Engineer-in-Charge
(l) Indicator lamp round/square suitable for any capacity geysers to the entire satisfaction of Engineer-in-Charge
(m)Thermostat switch 230 volts, 50 cycles AC suitable for geysers of capacity any capacity geyser as per existing make to the entire satisfaction of Engineer-in-Charge
(n) Metallic fuse able plug of existing make suitable for geyser any capacity to the entire satisfaction of Engineer-in-Charge
(o) Flexible chromium plated connection pipe size 450 mm long 15 mm bore with brass chromium plates coupling suitable for geyser any capacity to the entire satisfaction of Engineer-in-Charge
(p) Fixing outer cover suitable for 25 ltrs capacity geyser asper existing make to the entire satisfaction of Engineer-in-Charge
(q) Fixing outer cover suitable for 50 ltrs capacity geyser asper existing make to the entire satisfaction of Engineer-in-Charge
Preparing existing painted surface of geyser by washing and rubbing with ammery paper and applying white duco paint by spray painting machine to achieve glossy finish and colouring with red blue duco paint as ordered and rewriting of existing MES No.in letters and fgures 2 cm high with black paint complete to the entire satisfaction of Engineer-in-Charge
S&F brass/Gun metal non return valve 15mm dia including all fittings as per IS complete to the entire satisfaction of Engineer-in-Charge
S&F single pole & neutral enclosure with a two pin and earth plug and socket with one single pole 25 Amps 240 volts MCB fixed in repair to the entire satisfaction of Engineer-in-Charge
Supply & Fix 3 pin plug top 15 Amp to the entire satisfaction of Engineer-in-Charge
S&F switch socket combination 2 in 1 3 pin 5 Amp and 3 pin 15 Amps flush type universal to the entire satisfaction of Engineer-in-Charge
S&F Metallic top & socket 3 pin 20 Amps to the entire satisfaction of Engineer-in-Charge
Fixing only storage type electric heater(Geyser) any capacity including grouting 04 Nos fastner bolts of suitable size on wall and making good the exising surface and tightening with nut and washer and connecting electrically and to water supply and testing to the entire satisfaction of Engr In charge complete. Note: Geyser will be issued after repair for fixing only.
S&F stop valves, cast copper alloy, screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions 20mm bore fixed in repairs to the entire satisfaction of Engineer-in-Charge
S&F bib tap cast copper alloy chromium plated with crutch handle screwed down,screwed for Iron pipe or brass ferrule 15 mm bore fixed in repair complete to the entire satisfaction of Engineer-in-Charge
Taking up or down steel tubing and connections 15mm boreto the entire satisfaction of Engineer-in-Charge
Taking up or down steel tubing and connections 20mm bore to the entire satisfaction of Engineer-in-Charge
M&L for Steel water tubes,medium grade, ISI marked,galvanised,15mm bore with all fittings,fixed to walls and ceiling or laid in floorsto the entire satisfaction of Engineer-in-Charge
M&L for Steel water tubes,medium grade, ISI marked,galvanised,20mm bore with all fittings,fixed to walls and ceiling or laid in floors to the entire satisfaction of Engineer-in-Charge
S&F MCB,SP 20 Amp 240Volts,ISI marked,breaking capacity 10 KA, fixed in repairs including taking down old/unservicebleto the entire satisfaction of Engineer-in-Charge
M&L for repairing to head assy(appratus plate) by brazing,fixing wornout element holding studs, thermostat pipe of geyser of capacity 25/50 ltrs of existing maketo the entire satisfaction of Engineer-in-Charge
ARNABH ASSOCIATES
m/s shanti trading company
M/S BHARAT LIGHT ELECRIC.CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .