Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC Award of contract | |
| 2 | L2₹26.6 L+₹2.4 L (9.83%)Rejected-Finance NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹27.0 L+₹2.8 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹24.8 L
EMD Value
₹50,000
Closing Date
2 Mar 2024, 6:00 pmClosed
Garrison Engineer Haddo, Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
REPAIR/ MAINTENANCE OF COOLING APPLIANCE LIKE REFRIGERATOR, DEEP FREEZER, WATER COOLERS INCLUDING RO PLANTS AND DESALINATION PLANT UNDER GE HADDO, PORT BLAIR.
2024_MES_639726_1
8815/E8
Open Tender
Civil Works
Item Rate
270 days
GE Haddo Port Blair
Class E category b(i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹50,000
Yes
27 Mar 2024
30 Jan 2024
5 Mar 2024
30 Jan 2024
2 Mar 2024
14 Feb 2024
31 Jan 2024 - 7 Feb 2024
Amount
Taking down carefully window type AC of any capacity/any rating without any damage and install at new location including transportation, checking of gas and any leakages, brazing, pressure test all as directed.
Taking down carefully Indoor unit & outdoor unit of split type AC of any capacity/ any rating without any damage and install at new location including transportation, checking of gas and any leakages, brazing pressure test all as directed.
Taking out old unserviceable, burnt out sealed unit compressor by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically and electrically and S & Fixing new sealed unit compressor of approved make and capacity 230V, AC including transportation all as specified and directed. Note 1 : Refrigerant gas R-32 will be measured and paid separately under relevent item of this schedule 'A' Note 2 : For new compressor, contractor will produce OEM certificate and produce guarantee certificate for 5 years to the department.
Compressor for window/split type AC of capacity 1.5 TR
Compressor for window/split type AC of capacity 2/2.5 TR
Compressor for window/split type AC of capacity 3.0TR/3.5 TR (Vertical/Cassette type)
Compressor for refrigerator of capacity 165 to 180 ltr
Compressor for refrigerator of capacity 285/310 ltr
Compressor for water coller of capacity 40/80 ltr
Taking down unserviceable/damaged wall mounted copper cooling coil unit of split type AC (Inverter or reguar type) complete by means of disconnecting elecrical connection and suction and discharge pipe line and S&F new cooling coil unit of suitable capacity of existing (dismantled) model or equvialent make approved by Engineer-in-charge including remote control, proper fixing on wall, connecting to electrical system, suction and discharge pipe line, drain water pipe line all as directed, commissiong and testing complete for satisfactory performance of unit after gas charging of following capacity including transportation. Note:- Before taking down the unit the gas shall be stored in a container for refilling, additional gas (if requried) shall be measured and paid separately under respective items of this schedule
Suitable for split type AC of capacity 1.5 TR, 230 Volt AC
Suitable for Split type AC of capacity 2 TR, 230 Volt AC
Taking down unserviceable/damaged/rusted condenser unit of split type AC (Inverter/regular type) complete by means of disconnecting electrical connection, suction and discharge pipe line and S&F new condenser unit consisting of body, motor, condenser & blade suited for exisitng (dismantled) model or equivalent make approved by Engr-in-Charge, connecting to suciton and discharge pipe line to compressor after refixing compressor of existing unit all as directed, commissioning and testing complete for satisfactoroy performance of unit after Gas charging of following capacity including 14 RM suction and discharge copper pipe of adequate size with insulation. Note for Item No.4 & 5 Before taking down the unit the gas shall be stored in a container for refilling, additional gas (if required) shall be measured and paid separtely under respective items of this schedule
Suitable for 1.5 TR capacity
Suitable for 2 TR capacity
M&L Servicing of window type AC 1.5/2 TR capacity including leak testing with nitrogen gas, dehydrating/vaccumising, leak arresting, flaring, brazing and replacing of filter, cleaning and washing with causitc soda to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, painting to base tray and outer cover with two coat of synthetic enamel paint, including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
M&L Servicing of indoor & outdoor unit of split type AC 1.5/2 TR capacity including leak testing, leak arresting, brazing and replacing the filter after that cleaning/washing with caustic soda to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, painting to base tray with two coast of syntheic enamelled paint, including taking out and refixing the machine at its original location including transportaiton, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
M&L Servicing of Indoor & Outdoor unit of vertical type AC 305/3 TR capacity including leak testing between indoor and outdoor unit pipe line, leak arresting, brazing, and replacing the filter after that cleaning/washing with caustic soda to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, painting to base tray with two coast synthetic enamelled paint, including taking out and refixing the machine at its original location including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
M&L Servicing of indoor & outdoor of cassette type AC of any capacity disconnecting the indoor and outdoor unit of 3.0 TR capacity including leak testing between indoor and outdoor unit pipe line, leak arresting brazing, and replacing the filter after that cleaning/washing with caustic soda to condenser & cooling coil, cleaning of entire elements of AC, oiling/greasing to motor, painting to base tray with two coat of synthetic enamelled paint, including taking out and refixing the machine at its original localion including transportation, connecting of all electrical connections, testing & commissiong complete all as specified and directed.
M&L Servicing to water cooler of any capacity after disconnecting the water cooler from electric and water supply, cleaning/washing the condenser unit with use of Caustic Soda, cleaning the condenser coil, greasing the fan motor, checking/repairing the electric wiring thoroughly, cleaning of water storage tank, replacement of push cock washer, applying one coat of synthetic enamelled paint in basement area housing compressor & condenser and fan motor all as directed by Engineer-in charge including writing SM No with capacity in redium stickers, date of servicing and CA No. in 30 mm size letters with black paint. Note for Item No 06 to 10: 1 :The rate quoted including cutting, welding, brazing, and de-scaling refrigerant tubing. 2 : Spares will be measured and paid separately.
Taking out old/burnt blower motor and supply and fixing blower motor double shaft, single/double speed, single phase, AC, 230 V non inverter type (OEM approved) for the following capacity (as per sample) all as directed
Taking out old unserviceable fan blade and S & F new fan blade for window/split/tower type AC of any capacity.
Taking out of old/burnt blower motor, 230V and S&F new blower motor 230 V for indoor unit of split AC inverter tyoe of any capacity.
M & L for replacement of unserviceable remote control with PC board complete suitable for existing model of window type/split type/tower type of any capacity regular type (OEM approved make).
Material and labour for replacement of unserviceable PC board complete suitable for existing model of window type/split type/tower type/inverter type AC of any capacity (OEM approved make).
Material and labour for replacement of unserviceable remote control suitable for existing model of window type/split type/tower type/inverter type AC of any capacity (OEM approved make).
Material and labour for replacement fan motor capacitor of following capacities.
Material and labour for replacement of power contactor ML-3 type, heavy duty, three pole 415 Volt AC.45 Amps (AC1 rating) capacity with auxiliary contactor of (2 No + 2 NC) with coil voltage comple all as specified and as directed
Material and labour for replacement of power contactor ML-1.5 type, heavy duty, three pole 415 Volt AC.45 Amps (AC1 rating) capacity with auxiliary contactor of (2 No + 2 NC) with coil voltage comple all as specified and as directed
Material and labour for replacement of bi-metai overload relay, direct mounting type suitable for ML series contractor of range 13-21 Amps/20-32 Amps Make : L&T type, ML or equivalent make in GE/Siemens
Material and labour for replacement of electronic timer, type ET -100,230 volt AC.
Material and labour for replacement of single phase preventer model VSP - 1. Make : Minitec or equivalent model of approved make specified in appendix "B" to particular specification
Supply only Refrigerent gas in manufacturer sealed cylinder of following type:-
Supply only Refrigerent gas R-22/32 in manufactures sealed cylinder.
Supply only Refrigerent gas R-410/404/401a in manufactures sealed cylinder.
Taking down old unserviceble outdoor unit fan motor of capacity 11.5 TR air conditioner plant and supply & fix new fan motor of capacity 250 volts, 50 Hz, AC supply complete.
Material and labour for replacement of new cooling coil unit suitable for Refrigerator of capacity 165 to 180 Lts.
Material and labour for replacement of new cooling coil unit suitable for Refrigerator of capacity 285 to 310 Lts.
Material and labour for replacement of magnetic door panel gasket complete suitable for existing model of refrigerator of capacity 165 to 180 Lts including taking out of broken/unserviceable old existing one.
Material and labour for replacement of magnetic door panel gasket complete suitabel for existing model of refrigerator of capacity 285 to 310 Lts.
Taking out old unserviceable thermostat and Supply & Fix new thermostat of approved make and suitable size & model for the following.
Thermostat No 2059 with knob for window type AC
Auto 'D' themostat No 1027 with knob for refrigerator
Thermostat No 2064 with knob for water cooler
Taking out old unserviceable potential box type relay and supply & Fix new potential box relay/PTC relay of suitable model for window/split type AC capacity 1.5/2.0 TR
Taking out old unserviceable OLP - 1622 and Supply & Fix new OLP - 1622 relay for window type AC.
Taking out old/burnt starting capacitor/running capacitor and supply & Fix new starting capacitor of following capacities:-
Upto 36 MFD
40 MFD to 60 MFD
Material and labour for replacement of 3 core, 2.5 sqmm, copper conductor PVC insulated flexible cabel from main supply point to outdoor unit point as directed any specified by Engineer-in-charge.
Material and labour for replacement of 15mm bore PTMT float valve for water cooler of any capacity.
Material and labour for replacement of PVC flexible pipe 600 mm long complete for water cooler of any capacity.
Supply & fixing in repair carbon filter as per existing make & model
Supply & fixing in repair sediment filter as per existing make & model
Supply & fixing in repair RO Membrane filter as per existing make & model
Supply & Fix of Starter switch of capacity 25 amps, working on 240 volts AC supply, for air conditioner. Make : (Crabtree: Cat Part No. ACTO252504.
Supply & Fix in repair of exisiting microprocessor based ARTIC controlled board and fixed with new ARTIC board including suitabel sensor for window/split/tower/cassetter/Inverter type AC working on 415/230 volts, 50Hz all as directed.
Material and labour for insulation material of suitable size in repair to cover the indoor and outdoor unit of piping connection with suitable clamping all as directed.
Supply & Fix powder coated brakets of suitable for fixing of outdoor unit all as directed.
Material and labour for replacement of old/burnt out condenser fan motor, single shaft upto 40W capacity single phase, 230V AC for water cooler.
Material and labour for Replacement of unserviceable push cock,15 mm dia brass chromium plated for water
Supply & Fix in repair fan blade for water cooler of any capacity.
Material and labour for replacement of copper tubing, confirming to relevant IS of following sizes.
5/8" flare size.
1/2" flare size.
3/8" flare size.
1/4" flare size.
Supply & Fix in replacement of sheet metal enclosure with socket plug top & MCB single pole and Neutral enclosure with two pin and earth plug & socket complete with one single pole MCB 20 Amps complete all as specified and directed.
M&L for repairs to voltage stabilizer automatic opertion single phase of various make & capacity (0.5 to 5 KVA) by dismantling / opening the stabilizer for checking the parts/components, circuit for proper functioning, cleaning inside the stabilizer, replacement of defective minor itmes i.e screws, lugs, cut out/fuses, reset switches, rubber packing etc.re assembling the stabilizer testing on rated equipment load for automatic operation to stabilizer standard out put voltage, all as specified and directed by Engr-in-Charge Note:(i) Any spare part of stabilizer if found defective will be measured as supply and fix in repairs under respective item of this Schedule 'A' (ii) Cost of spare parts shall be included in the unit quoted rate
Supply and fix in repair electronic circuit card (PCB) suitabel for automatic single phase stabilizer 5KVA capacity of various make with high & low voltage cutout device but excluding ICS, as directed by Engr-in-Charge.
All as per item No 50 above but suitable for 4 KVA capacity stabilizer
Supply and fix in repair main transformer made from super enameled, copper wound conductor suitable for existing various make single phase stabilizer of capacity 5/4 KVA as specified & directed by Engr-in-Charge.
M&L for leak testing with nitrogen gas of window type AC 1.55/2 TR capacity including, dehydrating/vaccumising, leak arresting, flaring, brazing and taking out and refixing the machine at its original location including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
M&L for leak testing with nitrogen gas of Split type AC Upto 2.5 TR capacity including, dehydrating/vaccumising, leak arresting, flaring, brazing and taking out and refixing the machine at its original location including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
M&L for leak testing with nitrogen gas of vertical type AC Upto 4.0 TR capacity including, dehydrating/vaccumising, leak arresting, flaring, brazing and taking out and refixing the machine at its original location including transportation, connecting of all electrical connections, testing & commissioning complete all as specified and directed.
RK TRADERS
M/s Karbhagam Sales Agency
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .