Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹16.0 L+₹26,215.45 (1.66%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹22.1 L+₹6.4 L (40.5%)Rejected-Finance B 12 BASEMENT PLOT NO 19 RETAIL BUSINESS CENTRE ADITYA COMPLEX NANGAL RAYA SOUTH WEST NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
10 Mar 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
WELCOME MAINTENANCE OF B/R AND E/M WORKS IN H TYPE MD OFFRS ACCN AT SHANKAR VIHAR UNDER AGE BR II (S) OF GE (SOUTH) DELHI CANTT 10
2020_MES_312527_2
GE/DS-84/2019-20
Open Tender
Civil Works
Item Rate
330 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹56,000
Yes
24 Jun 2020
14 Feb 2020
12 Mar 2020
14 Feb 2020
10 Mar 2020
25 Feb 2020
15 Feb 2020 - 22 Feb 2020
Amount
Taking down cement or cement lime plaster on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for 5 mm thick rendering in CM 1:4 in ceiling on concrete surface finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on brick or concrete surfaces finished even and smooth without using extra cement) complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over a coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment , from wall through electrically operated grinder,/ Sand paper/ steel patti complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of surface as filling of holes with filler material and applying 3mm thick wall care putty in two layers inlcuding grinding with sand paper & levelling of surface complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of distemper oil emulsion, white or tinted over existing prepared putty base surface complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of surface as filling of holes with filler material etc and applying three coats of white wash on walls complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment , from ceiling through electrically operated grinder,/ Sand paper/ steel patti complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surface by filling of holes with filler material etc and applying three coats of white wash as in ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke, soot moulds, moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered or unplastered old decorated surfaces of ceiling by brooming down or steel wire brushing scraping down smoke, soot moulds, moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying one coat of white wash as in ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke, soot moulds, moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying one coat of oil bound distemper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke, soot moulds, moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying one coat cement base paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old Steel surfaces of any description not otherwise described over 10 cms width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cms width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated surface of walls/ceiling and applying one coat of exterior emulsion pain (weatherproof /Apex) including scaffolding arrangements upto two/three storey, trestles, ladders etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair , 20/25 mm dia Drappery Rod of MS tube powder coated type , including brackets powder coated any type, & , side PVC knobs for curtain any colour complete, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC side bulbs,/ holders any colour finish for drapery rods ends complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass of any thickness, size, quality or description n exc. 0.50 sqm in each pane from metal frame glazed with oil putty or fixed with beads including punching or out old glazing pins, spring clips, complete all as specified and directed by Engineer-in-Charge.
S&F, Sheet glass 4 mm thick , ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 sqm in each pan complete all as specified and directed by Engineer-in-Charge.
S&F 4 mm thick Figured glass , pin headed type in squares not exceeding 0.50 sqm each pane complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperature 1.40mm, fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
Dismantling boarding, any description, fixed in any position with nail complete all as specified and directed by Engineer-in-Charge.
M&L for 18/19 mm thick Prelaminated particle board,exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, as in cupboard and other wood work complete all as specified and directed by Engineer-in-Charge.
M&L for welding in repairs exe 9 mm but n exc 20 mm (Thickness of metal to be welded) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for switch piano flush type 6 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for switch piano flush type 6 Amps SP two way complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for bell push, flush type 6 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for socket outlet 2-in-1, 6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for switch piano type 16 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for universal socket outlet 2-in-1 (multipurpose) 3 pin 6/16Amps flush mounted type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for switch socket combination 4-in-1, 6 Amps flush type with indicator complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for switch socket combination 3-in-1, 6 & 16 Amps flush type with indicator complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for bell electric Ding Dong type 230 volts single phase complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for ceiling rose surface Bakelite of size 65 x 25 mm three terminals complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for old unserviceable plug top 15/16 Amps, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for electronic fan regulator minimum 4 Stepped Socket type, suitable for ceiling fan 1200/ 1400mm sweep as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for fan condenser 2.5 MFD as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for fan condenser 3.15 MFD as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Integrated Batten T5 20 watt (4 Ft) any type complete with new fliexble wire as required on site and including taking down of old unsv existing tube light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for LED Integrated Batten T5 10 watt (2Ft) any type complete with new fliexble wire as required on site and including taking down of old unsv existing tube light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for surface mounting round shaped LED down lighter with durable housing with aluminium heat shink with diffuser to give glare free light with removable driver 6 watt LED 6000K lamp type complete with and including, internally pre wired with all accessories, and including connecting up to fitting, complete all as specified and directed by Engineer-in-Charge. Make-C&S Cat Part No CORONA-RND/6W/W or equivalent in Havells/Philips/Benlo
S&F in repairs for PVC casing caping of size 20 x 12mm of ISI Mark or as per manufacturer design with all accessories for surface wiring and complete all as specified and directed by Engineer-in-Charge. (Make : Kalinga/AKG/Plaza as approved).
S&F in repairs Circuler Hylem Sheet upto 10 Cm dia of 3 mm thick (for using as Junction box Cover) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for plastic laminated sheet top cover 3mm thick of upto size 5"x8" fitted with MS galvanised screws and cup washer including shifting of all fixtures from the old switch board and connection complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for plastic laminated sheet top cover 3mm thick of upto size 9"x11" fotted with MS galvanised screws and cup washer including shifting of all fixtures from the old switch board and connection complete all as specified and directed by Engineer-in-Charge. Make :- Anchor/Hylum/Mayur.
Taking down hanging laminated sheet cover of any size and re-fixing the same after repairs by replacing rusted screws and cup wahers etc. complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for sheet metal enclosures with One No. 6/16A shuttered socket outlet, space for providing one No. MCB SP/MCB DP/Isolator as per site requirement of existing type complete all as specified and directed by Engineer-in-Charge.
S&F in repairs rigid non-metallic PVC surface plastic boxes (white) 4 module of size 85 x 145mm or as per manufacturer designed size and suitable for 15/16 Amps Switch socket combination outlet complete all as specified and directed by Engineer-in-Charge. (Make : Anchor/Cona/SSK as approved)
S&F in repairs rigid non-metallic PVC surface plastic boxes (white) 3 module of size 73 x 115mm or as per manufacturer designed size and suitable for 5/6 Amps Switch socket combination outlet complete all as specified and directed by Engineer-in-Charge. (Make : Anchor/Cona/SSK as approved)
M&L in repairs of PVC insulated FRLS single core with stranded copper cable of size 1.5 Sqmm single core for any type of wiring as per site requirement complete all as specified and directed by Engineer-in-Charge.
All as per item No. 53 here-in-before but cable of size 2.5 Sqmm.
All as per item No. 53 here-in-before but cable of size 4 Sqmm.
All as per item No. 53 here-in-before but cable of size 6 Sqmm.
All as per item No. 53 here-in-before but cable of size 10 Sqmm.
S&F in replacement for concealed sheet metal enclosures DB's with socket plug top and for incorporating MCBs single pole and neutral (DP) 2 way 20 amps MCB IP 30-double door 240 volts for geyser complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for SPN DB 8 way double door type with metal door and IP 43 protetions flush mounting for MCBs & connecting complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for VTPN DB 4 way double door type for fixing MCCB upto 200 Amps as incomer and MCB as out goinging with metal door and IP 43 protetions & connecting complete all as specified and directed by Engineer-in-Charge. Make Legrand/ABB/Crabtree.
S&F in replacement for MCCB 160 Amps 3 pole 415 volts fixed type with breaking capacity 36 KA 415 volts, including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB TPN of 63 Amps 415 volts, 'C' Series 10 KA or of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB TPN of 32/40 Amps 415 volts, 'C' Series 10 KA or of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB SPN/DP of 16 Amps 240 volts, 'C' Series 10 KA or of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB SPN/DP of 40 Amps 240 volts, 'C' Series 10 KA or of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB SPN/DP of 63 Amps 240 volts, 'C' Series 10 KA or of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB SP of 6 to 32 Amps 240 volts, 'C' Series 10 KA or of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for switch Piano modular type, 1 way 6A, 1module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for switch Piano, Modular switch 2 way 6A, 1module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Modular Bell push 6A, 1module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for switch Piano modular type 1 way 16A, 1module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Modular Socket, 6A - 5 pin combined 2module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for Socket 6/16A - 3/5 pin combined 2module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for stepped electronic fan regulator high speed modular type (minimum 4 Stepped), 120W - 2 module complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for white cover plate with frame, 2 module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for white cover plate with frame, 3 module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for white cover plate with frame, 4 module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for white cover plate with frame, 6 module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F for white cover plate with frame, 8 module as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Metra clad plug top 240 V, 20 A, 2P + E, upto of 20Amps capacity of Ivory or gray colour complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Metra clad Socket 240 V, 20 A, 2P + E, upto of 20Amps capacity of Ivory or blue cap colour complete all as specified and directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) complete all as specified and directed by Engineer-in-Charge.
All as per item No 83 above but One 3 pin socket outlet, 5/6 Amps, independent, with cables 1.5 sq. mm size with through existing concealed PVC/MS conduit complete all as specified and directed by Engineer-in-Charge.
All as per item No 83 above but 5 Amp socket outlet on same board with through existing concealed PVC/MS conduit complete all as specified and directed by Engineer-in-Charge.
All as Item No 83 above but for one socket outlet 5/15 Amps on Independent board with cables 4.0 sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit complete all as specified and directed by Engineer-in-Charge.
All as Item No 83 above but for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing with through existing concealed PVC/MS conduit complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of lamp holder Angle/Batten Type bakelite insulated body with back plate all as per site requirement complete all as specified and directed by Engineer-in-Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Chaudhary Constructions
S D Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .