Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H1₹2.1 LAccepted-Finance R O VILL GATROL PO DABLA TEH GHUMARWIN BILASPUR 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | H1 | Accepted-Finance H1 | |
| 2 | H2₹2.1 L−₹1,275 (0.60%)Accepted-Finance VILL JHANDUTTA SOAM P O TEH JHANDUTTA DISTT BILASPUR H P | BILASPUR | HIMACHAL PRADESH | 174001 | H2 | Accepted-Finance H2 | |
| 3 | H3₹2.1 L−₹4,485 (2.11%)Accepted-Finance | H3 | Accepted-Finance H3 |
Tender Value
₹2.1 L
EMD Value
₹4,250
Closing Date
15 Jan 2025, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Executive Officer HPAFMS
Directorate of Fisheries Matsya Bhawan Bilaspur HP
Construction of 1 No. Type-II residential quarter in Ranjeet Sagar Distt. Chamba H.P. (SH Providing E.I. therein).
2025_HAFMS_97545_1
2025_HPAFMS_1873_1
Open Tender
Civil Works
Item Rate
60 days
Ranjeet Sagar Distt. Chamba H.P.
Please refer Tender documents.
5 documents required · 5 mandatory
₹350
Chief Executive Officer HPAFMS
₹4,250
16 Jan 2025
6 Jan 2025
15 Jan 2025
6 Jan 2025
15 Jan 2025
6 Jan 2025
Amount
Construction of 1 No. Type-II residential quarter in Ranjeet Sagar Distt Chamba H.P. (SH:- Providing E.I. Therein)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductor single core cable etc as required.(a) Group-C as directed by engineer in charge
Supplying and fixing G.I. Modular box 3 Module with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of size 3 Module with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus). 5 amp switch
Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make: Legrand(Myrius),L&T(entice),Anchor(Roma Plus). 5amp Socket
Supplying and fixing following rating Modular switch /socket/Bell Push on the existing switch box / cover including connections etc. as required. (Make:-Legrand(Myrius),L&T(entice),Anchor(Roma Plus). Bell Push Modular
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x1.5 Sq. mm + 1X1.5 sq.mm
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x4 Sq. mm + 1X4 sq.mm
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 4x4 Sq. mm.+ 2X4 sq.mm
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. Make:- Finolex, KEI, Anchor, Plaza as approved by Engineer -in -charge . 2x10Sq. mm.+ 1X6 sq.mm
Providing, installation testing and commissioning of ceiling fan with regulator including wiring the down rods of standard length (up to 30cm) and 16/0.20mm twin twisted flexible cotten braided copper cable including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc as required including carriage of material within all leads and lifts. ( Usha technics,Crompten,Havells H S Velocity make or its equivalent. ) or as approved by the Engineer-in-Charge.1200 mm sweep
Providing and installation exhaust fan of300mm (Metal body) size in the existing opening,including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make:- Usha,Bajaj,Crompton or its equivalent as approved by Er-in-charge
Supplying and Fixing LED Battan 10watt (Mirror Light)High quility aluminium extruded with decorative end caps of superior quality ( Wipro Make ) as per item code LL20-111-XXX-65NE3 as required. Complete in all respect and as approved by the Engineer-in -Charge.Make-Wipro,Jaquar,Philips or its equivalent.
Supplying and fixing of fancy wall bracket containing thread type LED lamp holder (s) of all sizes and shapes, complete with all accessories but excluding LED lamp including making connections, testing etc. as required. (a) Fixed type wall bracket 150 dia, single lamp.(Category-A) MAKE PHILIPS
Supplying and fixing LED lamp 10 watt of Bajaj / Havells or its equivalent as required
Supplying and fixing of M.S.fan box (18 x 10 x 10) cm with phinolic laminated sheetcover in the front of M.S round 16 mm / 12 mm dia 60 cm long including connection complete in all respect as required or approved by the engineer incharge at site.
Supplying and fixing louvers / shutters for exhaust fan 300 mm as required or asapproved by the engineer incharge.
Supplying and fixing of following sizes medium class PVC conduit along with accessories in surface/ recess including cutting the walls and making good the same in case of recessed conduit as required . ( a) 25 mm dia
Supplying & fixing Modular blanking plate on the existing modular metal box as required.
Supplying and Fixing LED Battan 36 watt High quility aluminium extruded with decorative end caps of superior quality ( Wipro Make ) as per item code LL22-511-XXX-65-G1 as required. Complete in all respect and as approved by the Engineer-in -Charge.Make-Wipro,Jaquar,Philips or its equivalent.
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Supplying and fixing 5 amps to 32 amps , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.)Make L&T, Hager,ABB or its equivalent as per best satisfaction of Engineer-in -charge. Single pole
Supplying and erection of 40/50/63 amps, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of pole Double pole in the existing MCB DB complete with connections etc. as required:-Make L&T, Hager,ABB or its equivalent as approved by Engineer-in -charge.
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar,interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator).Make L&T ,Legrand, Hager or its equivalent as approved by Engineer-In-Charge MCBDB 16 WAY
Supplying and fixing true power make advanced earthing system having copper pipe 2 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 25 Kg compound including exvation of pit and refiling the same and making earthing pit cover 13 inch dia as required complete in all respect. make :-True power ,Earth plus,Ashloka or its equivalent as per best satisfaction of Engineer-in -charge.
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required. b) 25 liter capcity water heater (Cat-A)
Providing and installation of LED Street light 30W with bracket power coated pressure die cast aluminium high power led with heat resistant toughened glass with lens ,electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required.:Make ,wipro(LR26-371-XXX-65-XX),Panasonioc Philips or its equivalent as approved by Engineer-in -charge.( Five year warranty)
Providing and laying earth connections from earth electrode with 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing etc. as required.
AVNEESH SINGH (BID ID -470921)
RAHUL GAUTAM (BID ID -470976)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .