Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.5 LAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | ₹48.5 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹49.1 L+₹59,662 (1.23%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹49.1 L+₹59,662 (1.23%) | L2 | Rejected-AOC REJECTED |
| 3 | L3₹51.2 L+₹2.7 L (5.64%)Rejected-AOC | ₹51.2 L+₹2.7 L (5.64%) | L3 | Rejected-AOC REJECTED |
| 4 | L4₹53.9 L+₹5.4 L (11.2%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹53.9 L+₹5.4 L (11.2%) | L4 | Rejected-AOC REJECTED |
| 5 | L5₹54.2 L+₹5.7 L (11.7%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹54.2 L+₹5.7 L (11.7%) | L5 | Rejected-AOC REJECTED |
Tender Value
₹71 L
EMD Value
₹1.3 L
Closing Date
22 Mar 2021, 6:00 pmClosed
GE(NW) BHANDUP
GE(NW) BHANDUP, MUMBAI
SPECIAL REPAIR TO BUILDING SPDC 06 (SH32 AND RETURN STORE ) AT MO (MBI) GHATKOPAR UNDER GE(NW) BHANDUP
2021_MES_424600_2
8108/B
Open Tender
Civil Works
Item Rate
180 days
GHATKOPAR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE(NW) BHANDUP
₹1.3 L
27 Jul 2021
9 Mar 2021
23 Mar 2021
9 Mar 2021
22 Mar 2021
10 Mar 2021
Amount
Dismantling asbestos cement (corrugated semicorrugated, etc) sheets in roof covering including ridge, north light curves etc complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size & pattern) including all fitting, head shocs, bends etc complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/rigdes, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof, including necessary scaffolding etc complete all as specified and directed.
S&F 2 mm fibre glass reinforced translucent corrugated sheeting of a similar pattern as that of PPGI sheet with two corrugations side lap fixed with coach screw, GI 'J' or 'L' hooks in roof complete all as specified and directed.
S&F 160mm bore PVC rain water pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc complete all as specifed and directed.
Dismantling wrought iron or milt steel work of vallay gutter and expended metal any description not other wise provided for complete all as specified and directed..
S&F 1mm thick GI sheeting in ridges hips, valley gutters, drip etc necessary dismantling of AC sheets and refixing the same position and complete all as specified and directed.
S&F for roof trusses (framed) trussed, Purlins, crane gantries, rails and fastenings and heavy brackets framing(Beam, Angle, Channel or flat section,plain plates) including distance pieces, cleats ,welding and braceing etc,Fe-410W(Gde-E-250)quality -B, including necessary scaffolding etc complete all as specified and directed.
S & F Mild steel Angles, bars, flats ,plane angle cleats for securing to vallay gutter supports, wall ties,securing purlins J or L hook clamps with nut bolts,washers and similar small articles confirming to Fe 290 or Gde-E165 complete all as specified and directed.
Taking down chowkats or frames with shutters not exc 1.5 Sqm with shutters (without taking off shutters from the frames) complete all as specified and directed
M&L for 20 to 25mm machine cut pre polished kota stone slab as in riser of steps, skirting, window cills,dado and pillar laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 10 mm thick Rendering in CM1:4 complete all as specified and as directed.
S & F Mild steel Angles, bars, flats ,plane angle cleats for securing to vallay gutter supports, wall ties,securing purlins J or L hook clamps with nut bolts,washers and similar small articles confirming to Fe 290 or Gde-E165 complete all as specified and directed.
S&F aluminium section in doors / windows /ventilators sliding or openable or any type , powder coated in colour (Thickness of powder coating not less than 50 micron)(medium weight of series 'B') or as section directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including necessary pvc or rubber breading, track pvc or gasket for aluminium sections for fixing glass / bakelite sheet and all necessary fittings complete, screws, lock,plugs for fixing screws, etc all as specified and directed (Make : JINDAL/HINDALCO) Notes :- (a)Weight of aluminium sections shall only be measured. (b) The rate quoted shall be deemed to inclusive of necessary rubber breading, track pvc or gasket for aluminium sections for fixing glass / bakelite sheet
S&F aluminium anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed.
S&F turbine Air Ventilator, centre dia of ventilator 650mm + 5mm Height of ventilator 419 + 5mm, Dia of top plate 380 + 5mm, Dia of bottom ring 525 + 5mm, MOC of vanes made of industrial HI grade aluminium (Hindalco Make H-14, AA 1200 Grade), MOC of top plate made of 55304 (Aerodynamical), 10C of bottom ring 55304 (0.5mm), No of vanes-36 Nos rolled formed with lock washer 0.5mm thick, No of bearing 02 Nos (SKF/FAG-600122 permanently unbricated & sealed) riverts aluminium FRP base with dome, sheet size 1050 x 1800 x 2.0mm thick, exhaust capacity 1900 CFM, Weight of ventilator - 5kg and including necessary fixing arrangement, scaffolding etc complete all as specified and directed.
Taking down cement or cement lime mortar plaster, any description on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on brick walls, RCC pillars, beams, purlins etc and finishing the surface even and smooth complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats (10 + 5 mm), both coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed Note - WPC shall be measured and paid separately
Supply only integral water proofing compound.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
M&L for preparation of old decorated surfaces and applying two coat of white wash on wall, coloums, beams etc complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% anti fungal weather resistant acrylic paint over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.
M&L for complete removal of existing treatment on walls including washing down, rubbing down and applying antifungal treatement as required and applying two coats of 100% acrylic emulsion paint over a coat of primer as specified and directed by Engr-in-Charge
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide etc complete all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling carefully reinforced cement concrete work (including cutting of the reinforcement as required to facilitate dismantling) with low Impact Hammer / Breaker without dismantling the structure of any description and in any position not otherwise specifically provided for, cleaning and removing the retreived debris out side MD land, complete all as specified and directed.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for carry out application of Bi -polar migratory corrosion inhibitor (make, M/S Krishna conchem (EPCO KP -100) / BASF ( master protect 8000 CI) on RCC surfaces , complete all as spd and directed .( Note: Mode of measurment superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately).
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and disposing off the rubbish outside MD land complete all as specified and directed.
M&L for 100 mm thick Provding PCC 1:2:4 Type B-2( 40mm graded aggregate) as flooring complete all as specified and directed.
M & L for 20mm thick Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complete all as specified and directed
Supply only metallic floor hardener
Forming 12 mm thick expansion joint filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound grade A for 150mm thick concrete slab. etc complete all as spd and directed.
Forming construction joint 30mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and directed.
Dismantling of ceiling board (fibre, pulp,insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets etc complete all as specified and directed.
M & L for false ceiling of galvanised iron frame work of angle section of 15 x 15 x 28 gauge for support and main U section of 40 x 20 x 26 Gauge and supporting U clip of 32 x 18 x 26 Gauge and gypsum board of 12 mm thick in panels fixed to GI frame work including cutting, bolting, welding etc of GI frame work and joints filled and finished with POP and applying two coats of oil bound distemper over coat of alkali resistant primer with roller etc complete all as specified and directed.
M&L for filling cracks with polymer based chemical (Dr fixit cracks shrink free or equivalent) for cracks not exc 10 mm in width as per manufacturer instruction on wall surfaces on concrete or masonary including scaffolding etc complete all as specified and directed.
M&L for removal of loose and disintegrated concrete of RCC structural members viz slab, beam, column and lintel etc by low impact hammer including removal of debris outside MD land. Cleaning of exposed reinforcement bars with wire brush and apply two coats of anti-rust protective chemical at suitable intervals all as per manufacturer's instructions to resist further deteoration of reinforcement bars. Apply approved epoxy based bonding coat on concrete surfaces to achieve sound bond between existing and new concrete. M&L for profilling of structural members with polymer modified mortar 1:3 mixed with and including 15% latex polymer by weight of cement (w/c ratio 0.35) including leveling to match the surface. Application of complete treatment shall be through approved applicator all as per manufacturers instructions (Bauchemic Krishna or Sunanda) including scaffolding for following 20mm average thickness of polymer modified mortar complete all as specified and directed
Taking down carefully copper/aluminum point wiring of any type such as Concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc.
M&L for surface point wiring for light/fan controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including stove enamelled steel conduit having thickness not less than 2 mm with all fittings including steel sunk box having thickness not less than 2 mm including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)(Make of copper wire:Le Grand/Havells/Polycab and PVC conduit Make: Precision,Plaza)
All as per srl item No 44 above but for 5 pin 5 amps socket outlet on the same board with other switch all as specified.
All as per srl item No 44 above but for 5 pin 5 amps socket outlet indenpendent board of light point all as specified.
M&L for surface point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and in and including including stove enamelled steel conduit having thickness not less than 2 mm with all fittings including steel sunk box having thickness not less than 2 mm including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/standard/Havells and PVC conduit Make: Precision,Plaza)
M&L for point wiring with 4 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular sunk box having thickness not less than 2 mm including 4 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/standard/Havells and PVC conduit Make: Precision,Plaza)
Supply and fixing modular ceiling fan regulator 120 watt 2 module AC 240 volt complete all as specified and directed
Supply and fixing for switch modular one way 6/5 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
Supply and fixing for switch modular one way 15/20 amps 1 module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
Supply and fixing socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
Supply and fixing socket modular 16/20 Amp 2/3 pin combined 2 module complete all as specified and directed
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 8 module complete all as specified and directed.
M&L for submain wiring in and including PVC conduit having thickness 2 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 6 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 6 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed.Make:Legrand/Havells/polycab Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB SPN 240 Volts 16 to 40 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
Supply and fix in repairs sheet metal enclosure powder painted MCCB DB TPN 415 Volts 8 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer all as specified and directed.
Supply and fix in repairs MCCB 415 volts 16 KA TP 125 Amps complete all as specified.
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.Make : Fast Electrode or equivalent as approved by the GE.
Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates. (ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also. (iii) Necessary earth strip to connect equipment shall also provided by the contractor
Material and Labour for tube light fitting LED 20 watt with decorative end caps made out of CRCA sheet powder coated complete with housing t with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make: philips / Havells /CG, Tecnocomercially equivalent in Luccar etc Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Supply and fix in repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glass IP656,LEDs120/110 watts power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including aluminium die cast housing and aluminium heat sink on back side of fitting dismantling existing unserviceable 2x40 watts Flu. tube light fitting complete.Make: Make: Philips/Havells/CG/LUKER Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost. 2.Guarantee period of complete fixture should be minimum 3 years from the date of completion 3.Inspection by company Representative before installation at site at no extra cost.
Supply and fixing modular motor starter 25 Amp 2 module for AC complete all as specified and directed.Make:Legrand model No: 673466/Schneider/Seimens
Deduct Credit for Demolished/ Dismantled material Rs. (-) 126640.00 (Minus) as listed in Schedule of Credit Note: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum'
Parmatma Enterprises
ORIENT ELECTRIC CO
Joy builders
R J ENTERPRISES
RSG INFRASTRUCTURE
Rise and Rise Developers
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .