Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹6.2 L+₹40,581 (6.95%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹6.7 L+₹81,793 (14.0%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹6.8 L+₹91,059 (15.6%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹6.9 L+₹1.1 L (18.3%)Rejected-Finance H NO 243 VARADARAJ NAGAR VIDYARANYAPURA POST BANGALORE 560 097 | BANGALORE | BANGALORE | KARNATAKA | 560097 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
9 May 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Budha Ram,IDSE
AGE I AF CHIMNEY HILLS, CHICKABANAVARA,BANGALORE-560090
MAINT REPAIR TO SUMMER AND COOLING APPLIANCES AT 58 SU CHIMNEY HILLS
2023_MES_590019_1
8605/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
AGE I AF CHIMNEY HILLS BANGALORE
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
Yes
AGE I AF CHIMNEY HILLS BANGALORE
₹12,000
Yes
28 Aug 2023
18 Apr 2023
10 May 2023
18 Apr 2023
9 May 2023
2 May 2023
19 Apr 2023 - 25 Apr 2023
Amount
Servicing of window/split AC 1.5/2 TR capacities any make by opening the indoor/outdoor unit, cleaning the air filter, condenser including complete body of the unit with brush and air blower, washing with cleaning detergent & fresh water, greasing fan motor, rectification of loose electric connections and replacement of unserviceable knobs of electrical items complete all as directed Note : (i)Replacement of spare parts will be measured and paid separately under relevant items of BOQ.(ii) In case of shutdown of AC,Complaints shall be attended by Mechanic with in four hrs .(iii) If Contractors fails to attend the complaints within 4 hrs ,shall be imposed panelty 100 Rs per 4 hrs .
Supply and fix Starting Capacitor 80-100 mfd all as specified and directed .
Supply and fix Running Capacitor 36 mfd all as specified and directed .
Supply and fix Starting relay all as specified and directed .
Supply and fix Over load protector all as specified and directed .
Supply and fix Thermostat all as specified and directed .
Supply and fix Air Filter all as specified and directed .
Supply and fix Wiring kit complete set all as specified and dIrected .
Supply and fix Copper tube 1/2 " with adapter/flair nuts ,insulation foam all as specified and directed .
Supply and fix Copper tube 1/4 " with adapter/flair nuts,insulation foam all as specified and directed .
Supply and fix Copper tube 3/4 " with adapter/flair nuts,insulation foam all as specified and directed .
Supply and fix Copper tube 5/8 " with adapter/flair nuts ,insulation foam all as specified and directed .
Supply and fix PC unit/electronic circuit plate of appropriate make/model of 1.5/2 TR Acs all as specified and directed .
Supply and fix Remote control with batteries of appropriate make/model for Split type AC all as specified and directed .
Gas charging with refrigerant to Acs/water cooler/Deep freezer /Refrigerator including arresting of existing leakage by brazing work complete and all as specified and directed
Removing the existing defective / short circuited hermetically sealed compressor unit from the Acs and replace with the same company rewound sealed compressor unit of appropiate make / model for 1.0 TR AC.
All as per item No.16 above but 1.5 TR capacity.
All as per item No.16 above but 2.0 TR capacity
Removing the existing defective / short circuited Fan Motor from outdoor unit / indoor unit of 1.5 / 2Ton ACs and rewinding with super enameled copper wire of appropriate gauge and quantity with insulating materials and replacement of defective bearings / bushes / fan blade etc.and re-fixing the same and testing
Replacement of Cable PVC insulated and sheathed 3 core 4 sqmm by removing burnt cable from Acs
Replacement of rusted outdoor mounting stand set with new one for outdoor unit of Split type AC including nuts, bolts & wahers etc.
Removing the outlived Insulating teflon sheets from the existing copper tubes of Split type Air conditioners, S&F the same on copper tubes from inner unit to outer unit complete all as specified and directed.
Servicing of water cooler storage capacity 80/120 ltr and cooling capacity 40/60 Ltr per hour any make by opening, cleaning of water tank, cooling coil and condensers including complete body with brush, air blower, oiling/greasing fan motor rectification of loose electric connections and replacement of unserviceable drain pipe etc complete all as directed Note : Replacement of spare parts will be measured and paid separately under relevant items of BOQ.
Replacement Starting Capacitor 60-80 mfd for WaterCoolers all as specified and directed
Replacement Running Capacitor 25 mfd for water coolers all as specified and directed .
Replacement Starting Relay for water coolers all as speciifed and directed .
Removing the existing defective / short circuited hermetically sealed compressor unit from water cooler and replacement of the same with company rewound sealed compressor unit of appropiate make / model for water cooler 40/80 ltrs.
Removing the existing defective / short circuited hermetically sealed compressor unit from water cooler and replacement of the same with company rewound sealed compressor unit of appropiate make / model for water cooler 180 ltrs.
Servicing, maintenance and repairs to Refrigerator / Deep Freezer of capacity up to 310 Ltrs of any make and model including periodical cleaning to condenser coil and compresser, Replacement of defective spares will be measured and paid separately under relevant items as under complete all as specified and directed .
Replacements Starting Relay for Refrigerator all as specified and directed .
Supply and fix Ice cube Tray plastic set of two all as specified and directed .
Hard plastic Stand suitable for Refrigerator of any make / model up to 310 ltr.
Removing the existing defective / short circuited hermetically sealed compressor unit from the Refrigerator, Replacement of the same with company rewound sealed compressor unit of appropriate make / model for Refrigerator capacity upto 310 ltrs.
Servicing, maintenance and repairs to voltage stabilizer 5/4 KVA capacity of any make and model, S&F new suitable PCB complete all as specified and directed.
Servicing, maintenance and repairs to voltage stabilizer 3/2 KVA capacity of any make and model, S&F new suitable PCB complete all as specified and directed.
Supply and fix sheet metal enclosures with socket plug top of capacity alongwith 20 Amps MCB SP all as specified and directed by engineer in charge .
M&L Submain Wiring for circuit/submain wiring alongwith earth wire with FRLS , PVC insulated copper conductor, single core cable in surface as required 2 x 4 Sqmm + 1 x 4 Sqmm earth wire with PVC Conduit 25 mm dia all as specified and directed by engineer in charge .
JM Engineering
eurekaenterprises
M/S AMRITHESH ENTERPRISES
chowdeshwariconstructionco
ANAND REFRIGERATION
SAPTHAGIRI CONSTRUCTIONS
SRI LAKSHMI VENKATESHWARA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .