| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.6 LAccepted-Finance | 1 | Accepted-Finance First lowest | |
| 2 | 2₹27.8 L+₹15,638.30 (0.57%)Rejected-Finance | 2 | Rejected-Finance Second lowest | |
| 3 | 3₹30.3 L+₹2.7 L (9.62%)Rejected-Finance | 3 | Rejected-Finance Third Lowest | |
| 4 | 4₹36.9 L+₹9.2 L (33.4%)Rejected-Finance | 4 | Rejected-Finance Fourth Lowest | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹34.4 L
Closing Date
6 Apr 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, PBND, APWD, Port Blair
EE, PBND, APWD, Port Blair
Construction of 1.50 Lakhs Ltr Capacity Modular Rain Water Storage/ Harvesting System at Chief Engineer Office, APWD, Port Blair
2021_APWD_2737_1
NIT No. 90/EE/PBND/2020-21
Open Tender
Civil Works - Buildings
Item Rate
90 days
Port Blair, South Andaman
Please refer tender documents
5 documents required · 5 mandatory
₹0
Exempted
17 May 2021
20 Mar 2021
7 Apr 2021
20 Mar 2021
6 Apr 2021
29 Mar 2021
90 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manualmeans over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth leadupto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
(1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
Thermo-Mechanically Treated bars of grade Fe-500D or more
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form work for :
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
12 mm cement plaster finished with a floating coat of neat cement of mix :
1:3 (1 cement: 3 fine sand)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Single pushfit Coupler, 110 mm
Single tee with door, 110x110x110 mm
Bend 87.5°, 110 mm bend
Shoe (Plain), 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
25 mm dia nominal bore
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
25 mm nominal bore
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.
3 x 4 Sq mm
Supply & Fixing Non woven Geo textile having thickness of 400 gsm, having minimum tear strength of 250 ASTM D4533, width wise atleast 215 ASTM D4533 having puncture strength of 1550 plus as per ASTM D6241 having elongation at break % of 57 plus as per ASTM D4595 in two layers, made out of long fibres to hold the modules and project liner including cutting, sizing, head welding and needle punched for high porosity and proper percolation complete
Supplying and fixing of polymer/co-polymer based modular rainwater harvesting structure of approved make comprising of modules honey comb design/matrix made up of recycled poly propylene capable of taking light vehicular movement upto 30 tonnes/sqm with adequate backfilling (which shall be paid separately). The brand of modular rain water harvesting structure should confirm to CPWD rain water harvesting manual, specifications and to be approved by the Engineer-in-charge in complete accordance to the design and drawings of the manufacturer.
Supplying and fixing Central ground water board (CGWB)/Green rating for integrated habitate assessment (GRIHA) approved rain water filter or equivalent with minimum 700 mm dia with 110 to 150 mm dia inlet and outlet to accommodate rain water having desilting suspended solid catcher made out of FRP with stainless steel 304 grade strainers having stainless steel bucket of 600 micron capable of eliminating finer particulate matter upto 160 micron filtration made of stainless steel net with long fibre foam of 25 mm thickness, filtration capacity 20-40 kilolitres per hour complete in accordance to the manufacturer design, drawing and specification and complete and the make to be approved by the Engineer-in-charge. The total depth of filter shall be of minimum 1000mm.
Supply & Fixing HDPE liner of approved brand of 1.2mm thick for the collection of water incuding heat welding onsite and offsite as per the requirement and direction of Engineer-in-charge.
Supplying and fixing FRP based access inspection chamber of minimum, size 500x 500x 500 mm complete as per the direction of Engineer-in-charge., of approved brand.
Providing and fixing PVC joint bracket with two clamps half round 250mm all complete as per the direction of Engineer -in-charge.
Providing and fixing PVC elbow with / without outlet and two clamps half round 250mm all complete as per the direction of Engineer -in-charge.
Providing and fixing PVC short stop end half round 250mm all complete as per the direction of Engineer -in-charge.
Providing and fixing PVC stop end outlet with two clamps half round 250mm all complete as per the direction of Engineer -in-charge.
Providing and fixing PVC Running outlet with two clamps half round 250mm all complete as per the direction of Engineer -in-charge.
Providing and fixing half round PVC gutter of 250mm semi circular of approved make for rain water harvesting structure excluding supporting accessories like PVC brackets, elblow, short stop end, stop end outlet of required size. PVC brackets placed 1 mtr apart centre to centre with necessary screws, sealents etc. all complete as per the direction of Engineer -in-charge. ( supporting accessories to be paid separately) :
Supplying Installation, testing and commissioning of 1.05 HP (1.1 KW) self priming single phase, 220V having suction and delivery 25 X 25 mm dia. Water pump set as equivalent to Kirloskar Brothers Ltd Model No. MEGA 54S 1.5HP.
Supplying and lying of one number double walled corrugated on the outer wall and plain surface inner wall confirming to IS 14930 part-I complete with necessary HDPE fitting for protection of 1.1 KV grade depth of 50 cm in the existing cable trech etc as required.
Supplying and laying of one number double walled corrugated high density polythlene pipe having corrugation on the outer wall and plain surface inner wall confirming to IS 14930 Part-I complete with necessary HDPE fitting for protection of 1.1 KV grade underground cable directly on the surface or wall etc as required.
Supplying and fixing of 6 pin 5/6 & 15/16 amps sockets outlet and 15/16 amps piano type switch along with kit kat fuse unit assemble in a PVC surface box as equivalent to ANCHOR Capton 5-in-1 Combine Unit (Switch Socket Fuse & Indicator), 240 V Code No.14618 or its equivalent.
KAKOLIL TRADE AGENCIES
KML Construction
N V JOHN
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .