| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹49.1 LAccepted-AOC 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹61.1 L+₹7.2 L (13.3%)Rejected-Finance | 2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | 3₹64.6 L+₹10.7 L (19.8%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | 3 | Rejected-Finance NOT L1 BIDDER | |
| 4 | 4₹66.8 L+₹12.8 L (23.8%)Rejected-Finance P 21 MANAS BAG KOLKATA 700 056 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | 4 | Rejected-Finance NOT L1 BIDDER | |
| 5 | 5₹66.9 L+₹12.9 L (24.0%)Rejected-Finance 35 P C MUKHERJEE STREET PO KONNAGAR DIST HOOGHLY PIN 712235 | KONNAGAR | HOOGHLY | WEST BENGAL | 712235 | 5 | Rejected-Finance NOT L1 BIDDER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
28 Sept 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
MISC E AND M REPAIRS AND AUGMENTATION OF E AND M SERVICES AT KANKINARA UNDER GE N KOLKATA
2022_MES_545884_2
8191/22-23/E8/GE(N)/KOL/ OF 2022-23
Open Tender
Miscellaneous Works
Item Rate
270 days
KANKINARA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹1 L
Yes
8 Oct 2022
20 Sept 2022
29 Sept 2022
21 Sept 2022
28 Sept 2022
21 Sept 2022
60 days
Amount
Excavation in trenches not exceeding 1.5 m width or n exc 10 sqm on plan and n.exe 1.5 m in depth for taking out/laying of cable,foundation etc and getting out in soft/loose soil complete all as specified and as directed.
All as per Item No-1 above, but depth exceeding 1.5 m and not exceeding 3.0 m
Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft / loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtrs and depositing where directed including spreading, leveling at a level not exceeding 1.5 mtr from the starting point complete all as specified and as directed
Cutting hard standing/ road for laying of cable and filling with PCC 1:3:6 of size not less than 30 cm X 30 cm complete all as specified and directed.
Taking up or down worn out/ damaged/partly serviceable / unserviceable PVC insulated cable, armoured, heavy duty with aluminium conductors of any size, 1100 volt grade from pole / wall / pipes / roof tops etc,testing,segregating and kepping in safe castody the serviceable portion for reuse and depositing remaining to the stores complete all as specified and directed.
Taking up or down worn out/ damaged/partly serviceable / unserviceable PVC insulated underground cable, armoured, heavy duty with aluminium conductors any size, 1100 volt grade from trench ,testing,segregating and kepping in safe castody the serviceable portion for reuse incl bricks, stacking serviceale bricks for reuse complete all as specified and directed. (NOTE :-Excavation wherever required will be measured and paid separately)
Supply and fixing, commissioning, testing XLPE insulated PVC sheathed armoured heavy duty electric cable with aluminium conductor for working voltage upto and including 1100 volts, in duct / trenches, fixed to pole, wall/roof and make good including cable glands required size of aluminium thimble for making connection complete of size 500 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
All as per item No. 8 but of size 400 sq mm, 3.5 core.
All as per item No. 8 but of size 300 sq mm, 3.5 core.
All as per item No. 8 but of size 240 sq mm, 3.5 core.
All as per item No. 8 but of size 120 sq mm, 3.5 core.
All as per Item No. 8 above, but 95 sq mm, 3.5 core.
All as per Item No. 8 above, but 70 sq mm, 3.5 core.
All as per item No. 8 but of size 50 sq mm, 3.5 core.
All as per Item No. 8 above, but 35 sq mm, 3.5 core.
All as per Item No. 8 above, but 25 sq mm, 3.5 core.
All as per item No. 8 but of size 16 sq mm, 4.0 core.
All as per item No. 8 but of size 10 sq mm, 4.0 core.
All as per item No. 8 but of size 16 sq mm, 2.0 core.
All as per item No. 8 but of size 10 sq mm, 2 core.
Material and labour for sand cushioning with clean dry sand laid in trenches for cable protection complete all as specified and directed.
Supply and lay sub class 'B' bricks, laid dry in trenches for cable protection laid with its longitudinal axis perpendicular to the cable axis complete all as specified and directed
All as Item No. 17 above but laying only (serviceable Bricks, obtained from above item no 7 shall be reused)
Supply and fix galvanised iron pipe in 40 mm bore, light grade for protection of UG cable laid in trenches / fixed to pole with MS clamp,nut, bolt etc complete with all fitting such as socket or any other item required for fixing of pipe including taking down old unserviceable one complete all as directed. (Note :- MS clamp, nut,bolt etc required for fixing the pipe with pole shall be deemed to be included in the quoted rate).
All as per Item No. 25 here in before but for size 50 mm bore.
All as per Item No. 25 here in before but for size 80 mm bore.
Material and labour for PCC (1:4:8) type D-2, (using 40 mm graded stone aggregate) as in foundation , filling and mass concrete for pole , etc complete all as specified and directed
Material and labour for PCC (1:3:6) type C-1, (using 20 mm graded stone aggregate) as in coping of poles, repair of platform for Panels / Feeder Pillar Boxes, foundations etc including necessary form work complete all as specified and directed.
Supply and Errection steel tubular swaged welded poles 9.0 metr long conforming to IS-2317/1980 type 410 SP-31 complete with cast iron base plate final taper plug, bolts, nuts and screws etc including two coats of aluminium paint over a coat of red oxide primer, zebra painting upto 1.5 mtr height in yellow and black colour strips in alternate layers of 150mm width complete including taking out damaged steel tubular pole and PCC work all as specified and directed. (NOTE : Earth work and PCC work for base and coping shall be measured and paid separately)
Supply and fix LED STREET light 90 Watt die cast aluminium housing with IP-65 protection and surface mounting device LED 90 Watt with lens including all fixing arrangement required to fixed with pole/ wall on existing bracket or wall including suitable size of fixing items such as clamps, nut bolts and washer of suitable size and connecting with existing electric supply with three run single core 1.5 sqmm copper conductor cable with flexible PVC conduit and making connections complete including taking down old light fitting any type complete all as specified and directed by Engr-in-Charge.
Material and labour for street light fitting bracket, made out of 40 mm bore GI pipe, light grade of length not less than 1.20 mtr, 45 degree bend to shape and fixed on pole with 2nos FI clamps of 40x5mm of suitable length made shape of pole , bolts, nuts & washers including taking out old unsv bracket complete all as specified & directed.
Supply and fix cable junction box of inside dimension 205 x 255 x 112 with provision of 4 Nos aluminium bus bar of size 25x5mm/ connector for cable of suitable size to be fixed on pole/ wall/ angle with suitable size of clamp, nut bolts and washer, angle etc required at site for fixing of junction box including taking down old unserviceable junction box with mild steel work complete all as specified and as directed. Make - Hensel/ Syntex/ National
Supply and fix and connected in replacement of busbar chamber 4 strip, electrolytic copper busbar capacity 100 Amps ,suitable length for 4 way out going to be fixed/ mounted on pole /post / wall/ angle with suitable size of clamp, nut bolt, washer, angle of suitable size, etc required at site for fixing of bus bar complete including taking out the old unserviceable busbar unit complete all as directed Make : Havells/ C&S / Indoasian
Supply and fix and connected in replacement of busbar chamber 4 strip, electrolytic copper busbar capacity 200 Amps ,suitable length for 4 way out going to be fixed/ mounted on pole /post / wall/ angle with suitable size of clamp, nut bolt, washer, angle of suitable size, etc required at site for fixing of bus bar complete including taking out the old unserviceable busbar unit complete all as directed Make : Havells/ C&S / Indoasian
Supply and fix and connected in replacement of busbar chamber 4 strip, electrolytic copper busbar capacity 250 Amps ,suitable length for 4 way out going to be fixed/ mounted on pole /post / wall/ angle with suitable size of clamp, nut bolt, washer, angle of suitable size, etc required at site for fixing of bus bar complete including taking out the old unserviceable busbar unit complete all as directed Make : Havells/ C&S / Indoasian
Supply and fix and connected in replacement of busbar chamber 4 strip, electrolytic copper busbar capacity 315 Amps ,suitable length for 4 way out going to be fixed/ mounted on pole /post / wall/ angle with suitable size of clamp, nut bolt, washer, angle of suitable size, etc required at site for fixing of bus bar complete including taking out the old unserviceable busbar unit complete all as directed Make : Havells/ C&S / Indoasian
Supply and fix and connected in replacement of busbar chamber 4 strip, electrolytic copper busbar capacity 400 Amps ,suitable length for 4 way out going to be fixed/ mounted on pole /post / wall/ angle with suitable size of clamp, nut bolt, washer, angle of suitable size, etc required at site for fixing of bus bar complete including taking out the old unserviceable busbar unit complete all as directed Make : Havells/ C&S / Indoasian
Material and labour for heat shrinkable straight through joint outdoor termination for PVC/ XLPE insulated armoured cable of 240 to 400 sqmm 3.5 core including taking out cable and fixing joint complete all as specified and directed. Make - Raychem / Mseal / Denson
Material and labour for heat shrinkable straight through joint outdoor termination for PVC/ XLPE insulated armoured cable of 70 to 185 sqmm 3.5 core including taking out cable and fixing joint complete all as specified and directed. Make - Raychem / Mseal / Denson
Supply and fix in replacement of MCCB 4 Pole, 800 Amps,AC, 415Volt , rapturing capacity 50 kA with adjustable thermal setting and adjustable magnetic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. Make : Indoasian/ Havells/ C&S
Supply and fix in replacement MCCB 4 Pole, 630 Amps,AC, 415Volt , rapturing capacity 50 kA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. Make - Indoasian/ Havells/ C&S
Supply and fix in replacement MCCB 4 Pole, 400 Amps,AC, 415Volt , rapturing capacity 36 kA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. Make - Indoasian/ Havells/ C&S
Supply and fix in replacement MCCB 4 Pole, 315 Amps,AC, 415Volt , rapturing capacity 36 kA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. Make - Indoasian/ Havells/ C&S
Supply and fix in replacement MCCB 4 Pole, 200 Amps,AC, 415Volt , rapturing capacity 25 KA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. Make - Indoasian/ Havells/ C&S
Supply and fix in replacement of MCCB 4 Pole, 100 Amps,AC, 415Volt , rapturing capacity 16 KA with adjustable thermal setting and adjustable magnatic setting as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. Make - Indoasian/ Havells/ C&S
Supply and fix in replacement MCCB 63 Amps, four pole, 415 volts,16 KA as per site including suitable size of connector and fixing materials such as thimble, nut bolts, etc of suitable size complete all as specified and directed. Make - Indoasian/ Havells/ C&S
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron earth lead wire 4.0 mm dia length upto 7.5 mtr by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (light grade) not exc 7.5 mtr, alternate layers of charcoal and salt, including 20 mm bore GI tubing for watering to earth electrode, earth lead connected to test point/ distribution panel /feeder pillar etc as directed including necessary earth work, concrete pit with PCC (1:3:6) type C1, pre cast RCC(1:1:5:3) type A1 cover slab duly reinforced with 8 mm dia TMT bar 150mm c/c both way and two numbers lifting handle made of TMT bar and set in cement mortar (1:4), funnel, wire mesh, all as shown in electrical plate No 3 of SSR part-1 and testing on completion including taking out old earthing complete all as specified and directed by Engr-in-charge.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire including taking out old wire complete all as specified and directed.
S&F GI pipe 15 mm bore 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking out old pipe complete all as specified and directed.
Matetial and labour for sub-main wiring in repairs with two run of FRLS PVC insulated unshethed single core multi-stranded copper conductor of size 2.5 sqmm and one run of 1.5 sqmm copper conductor as continuity earth wire drawn in and including PVC conduit of suitable size but not less than 20 mm dia fix to pole with FI clamps 20x3mm thick of suitable length made to size of pole at a height of 1mtr each to be fixed on pole including PVC fittings such as bends Tee and boxes including taking down old unserviceable pole wiring of any size in steel/ PVC rigid conduit complete all as specified and directed (Note : (i) Two run of 2.5 sqmm cable one run of 1.5 sqmm cable alongwith PVC conduit shall be measured and paid as one unit. (ii) Cost of fixing material such as GI wire and FI clamps 20x3mm thick of suitable size / any item, if any, required for housing of PVC casing conduit etc on pole and also making good the disturbed surfaces are deemed to be included in unit rate.)
NANDYENTERPRISES
Tirupati Buildcon Pvt. Ltd.
The Planters Engineering Corporation
M/S MAHENDRALALL DUTTA
BHASKAR SUPPLY AGENCY
RUNJEN CONSTRUCTION
RBS Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .