Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.4 LAccepted-AOC B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | 1 | Accepted-AOC Lowest Bidder | |
| 2 | 2₹22.8 L+₹4.9 L (27.6%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | 2 | Rejected-Finance Not Lowest the Bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT FULFILL ELIGIBILITY CRITERIA | |
| 4 | Rejected-Technical G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | - | Rejected-Technical NOT FULFILL ELIGIBILITY CRITERIA |
Tender Value
₹23.0 L
EMD Value
₹45,960
Closing Date
15 Oct 2021, 6:00 pmClosed
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT-10
GENP-50/2021-22 REPAIR/MAINTENANCE OF FIRE FIGHTING, DG SET AND OTHER CONNECTED ITEMS AT AF STATION PALAM UNDER GE (AF) PALAM, DELHI CANTT-10
2021_MES_475775_1
GENP-50/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹45,960
Yes
10 Nov 2021
16 Sept 2021
16 Oct 2021
16 Sept 2021
15 Oct 2021
1 Oct 2021
Amount
Supply and fixing fire hydrant landing valve type 'A' (single head outlet) gun metal valve of 80mm dia landing valve with 63mm dia female outlet complete suitable and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with coupling conforming to IS : 903 including taking down the existing one complete all as specified and directed by Engr-in-charge.
Supply and fixing of weather proof standard fire hose box made of 16SWG Mild sheet 800mmX600mmX250mm with double door with 4mm thick glass and door frame including locking arrangement by allen key stove enamelled fire red finish with "fire hose" marked on front and brilliant white inside yard, suitable for housing of and consisting of two length RRL15 mtr hose pipe conforming to IS 636-1979 (type-II) of 63mm dia Gun metal instantaneous male and female (IS:903) and branch pipe and nozel 15 mm dia (for external hydrant) including taking down the existing one complete all as specified and directed by Engr-in-charge.
M&L for maintenance and servicing of standby DG Set complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleaner , change air cleaner elements, Check coolant level & make up the same , drain the Fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unserviceable brass Connectors for batteries , Cleaning of Battery terminals & applying petroleum jelly to battery terminal posts & brass connectors , changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, Checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM , oil pressure, oil temp,Coolant temp, Voltage, frequency , load current , battery charging , fuel consumption etc. as directed by the Engr in charge for 125 KVA DG Set. Make – Kirloskar installed at Tech Pump house ,Pinto park pump house and RV Pump house. (Note :- 1. Engine oil for refilling will be measured and paid separately under respective items. 2. Coolant for make up will be measured & paid separately under respective items. 3. DHPP will be issued by dept for testing only)
All as per item No. 03 above but for 70 KVA DG Set installed at Old and new domestic pump house Camp area.
All as per item No. 03 above but for 50 kVA DG Set installed at CPRU pump house,Map pump house and old pinto park
All as per item No. 03 above but for 40 KVA Make: Cumins at STP pinto park and new STP
All as per item No. 03 above but for 35 KVA installed at MT Astha pump house and Map pump house camp area.
All as per item No. 03 above but for 15 kVA DG Set installed at 1AFSR and Maude line borewell
All as per item No. 03 above but for 200 KVA DG Set installed at CPRU,colour lab and UGBO .
Supply and filling lubricating oil for DG Sets as per manufacturer's recommendation. Make : IOC, Castrol, Hindustan Petroleum.
Supply and filling coolant for Radiator as per manufacturer's recommendations.
M&L for Overhauling of radiator assembly by removing from engine, transporting to the workshop and removing the sediments and scales, corrosion etc by means of acid cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality material for stopping the leakage etc, re-assembling the same with new gaskets and transporting to the site, fixing to the engine with new hoses, clips complete as required for DG Set of capacity 125 KVA.
All as per item No. 12 above but for 70 KVA .
All as per item No. 03 above but for 50 KVA.
All as per item No. 03 above but for 40KVA.
All as per item No. 03 above but for 35 KVA.
All as per item No. 03 above but for DG Set 15 KVA .
All as per item No. 03 above but for DG Set 200 KVA.
Suppply & fixing in replacement of RPM Meter on DG Set complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of Battery lead 1.25mtr long made of 25Sqmm single core copper conductor (Positive & Negetive) including fixing of both end brass terminal (ring type & screw type) complete all as specified and as directed by Engr-in-charge.
Supply only distilled water in one litre container.
Supply only sulphuric acid for lead acid battary in one litre container.
M&L for servicing of self starter assembly of DG Set up to 200 kVA capacity 24 volts by disconnecting the self starter from the engine and transport to workshop for carryout overhauling by replacing all unserviceable spare parts including pinion, coabon brushes , bushes, contacts, copper plates, jumping leads ets and replacing the filled coil and varnishing all as directed.
Supply & fixing in replacement of inter connected Battery lead to connect two nos battiers of capacity 12Volt 150/180AH made of 25 Sqmm single core copper conductor including fixing of both end brass terminal (screw type) complete all as specified and as directed by Engr-in-charge.
Draining out existing radiator water, cleaning thoroughly the radiator fins by air blower, recharging the chemically treated coolant including replacement of all water hose pipe suitable for 15 kVA to 200 kVA DG Sets.
Supply and fixing in replacement of radiator ' V' ' belt suitable for 125 KVA DG set all as specified and directed by Engr-in-charge.
All as per item No. 26 above but for 70 KVA DG set
All as per item No. 26 above but for 50 KVA DG set
All as per item No. 26 above but for 40 KVA DG set
All as per item No. 26 above but for 35KVA DG set
All as per item No. 26 above but for 15 KVA DG set
All as per item No. 26 above but for 200 KVA DG set
M&L for preparation of old painted surface of fuel tank by scrapping / removing old paint , dirt etc and painting with two coats of blue synthetic enamel paint over a coat of red oxide primer including calibration of capacity of tank and marking the level of capacity all as specified and directed by Engineer-in-charge suitable for:- (a) Fuel tank in respect of 125KVA DG set capacity -03 Nos. (b) Fuel tank in respect of 70KVA DG set capacity -02 Nos. (c) Fuel tank in respect of 50KVA DG set capacity -01No. (d) Fuel tank in respect of 40KVA DG set capacity -02 Nos. (e) Fuel tank in respect of 35KVA DG set capacity -02 Nos. (f) Fuel tank in respect of 15KVA DG set capacity -02 Nos. (g) Fuel tank in respect of 200KVA DG set capacity -03 Nos.
Dismantling existing fuel injection pump of DG set 200 KVA , transporting to work shop and overhauling complete including calibrating and re-fixing the same and testing the DG Sets installed at CPRU ,Colour lab and UGBO to the entire satisfaction of Engineer-in-charge.
All as per item No. 34 above but for 125 KVA DG set installed at Tech pump ,pinto park pump house& RV Pump house.
All as per item No. 34 above but for 70 KVA DG set installed at Old domestic pump house.
All as per item No. 34 above but for 70 KVA DG set installed at New domestic pump house.
All as per item No. 34 above but for 50 KVA DG set installed at Map pump house and old pinto park.
All as per item No. 34 above but for 50 KVA DG set installed at CPRU pump house.
All as per item No. 34 above but for 40 KVA DG set installed at STP pinto park and new STP.
All as per item No. 34 above but for 35 KVA DG set installed at MT astha pump house.
All as per item No. 34 above but for 35 KVA DG set installed at Map pump house camp areae.
All as per item No. 34 above but for 15 KVA DG set installed at 1AFSR BOREWELL.
All as per item No. 34 above but for 15 KVA DG set installed at Maude line borewell.
Dismantling rubber coupling of DG set and supply and fixing rubber coupling for following DG sets including testing and commissioning complete:- a) CPRU ,colour lab and UGBO -200 KVA b) Tech pump ,pinto park pump house RV Pump house-125 KVA c) Old domestic pump house-70 KVA d) New domestic pump house-70 KVA e) Map pump house and old pinto park -50 KVA f) CPRU pump house -50 KVA g) STP pinto parkand new STP -40 KVA h) MT astha pump house -35 KVA j) Map pump house camp areae -35 KVA k) 1 AFSR BOREWELL -15 KVA
Supply and fixing in replacement of flexible fuel hose pipe suitable for 200 KVA DG set at CPRU ,colour lab and UGBO.
All as per item No. 46 above but for 125 KVA DG set installed at Tech pump ,pinto park pump house & RV Pump house.
All as per item No. 46 above but for 70 KVA DG set installed at Old domestic pump house.
All as per item No. 46 above but for 70 KVA DG set installed at New domestic pump house.
All as per item No. 46 above but for 50 KVA DG set installed at Map pump house and old pinto park.
All as per item No. 46 above but for 50 KVA DG set installed at CPRU pump house.
All as per item No. 46 above but for 40 KVA DG set installed at STP pinto park and new STP.
All as per item No. 46 above but for 35 KVA DG set installed at MT astha pump house.
All as per item No. 46 above but for 35 KVA DG set installed at Map pump house camp area.
All as per item No. 46 above but for 15 KVA DG set installed at 1 AFSR BOREWELL.
All as per item No. 46 above but for 15 KVA DG set installed at Maude line borewel.
Supply and fixing in replacement of water temperature gauge of DG set and testing complete.
Supply and fixing in replacement of Oil Pressure gauge of DG set and testing complete.
Supply and fixing in replacement of self starter of capacity 24 volts DC suitable for 70 KVA DG Set at New domestic pump house.
Supply and fixing in replacement of self starter of capacity 24 volts DC suitable for 200 KVA DG Set at UGBO.
Disconnecting existing defective voltage stabilizer at different location of 3 X 15 KVA capacity 3 phase 415 volts from electric mains, Isolating the naked connections , removing from foundations by unscrewing the nuts bolts etc carrying to the factory /workshop for repair by draining out the transformer oil through the drain plug , dismantling both nut and bolt and lifting the top portion to carry out through inspection and clean the bottom portion of the voltage stabiliser tank by removing the mud and slurry and deposited material for prevention of short circuit and re-fixing in Original position after repair and testing complete all as specified and as directed by Engineer -in - charge .(NOTE:- Replacement of defective parts shall be measured and paid separately )
Disconnecting existing defective voltage stabilizer of 50 KVA capacity 3 phase 415 volts from electric mains, Isolating the naked connections , removing from foundations by unscrewing the nuts bolts etc carrying to the factory /workshop for repair by draining out the transformer oil through the drain plug , dismantling both nut and bolt and lifting the top portion to carry out through inspection and clean the bottom portion of the voltage stabiliser tank by removing the mud and slurry and deposited material for prevention of short circuit and re-fixing in Original position after repair and testing complete all as specified and as directed by Engineer -in - charge . (NOTE:- Replacement of defective parts shall be measured and paid separately )
S&F in replacement of Electronic circuit card (PCB) suitable for Existing Make - Volina voltage stabilizer.
S&F in replacement of PCB Holder suitable for Existing Make - Volina voltage stabilizer.
S&F in replacement of rotary switch 5 Amps for RYB Phase .
S&F in replacement of Micro processor based control card for Each phase ( Set of Three ).Suitable for Existing Make - Volina
S&F in replacement of Dimmer state unit 10 Amps suitable for Existing Make - Volina voltage stabilizer.
S&F in replacement of Dimmer state unit 60 Amps suitable for Existing Make - Volina voltage stabilizer
S&F in replacement of Digital Amp Meter with CTs suitable for Existing Make - Volina voltage stabilizer
S&F in replacement of Voltmeter 0-500 Volts digital type suitable for Existing Make - Volina/ABB voltage stabilizer.
S&F in replacement of Panel lamp as per Existing ( set of three ).
Supply & fixing in replacement of Main Transformers suitable for servo voltage stabilizers of capacity 15 KVA complete. M
Supply & fixing in replacement of Main Transformers suitable for servo voltage stabilizers of capacity 50 KVA complete.
S&F in replacement of MCCB 3 pole 415 volts 125 Amps of breaking capacity 35 KA frame LS .
Supply and filling Transformer Oil at adequte temperature (without moisture) for top up as required suitable for voltage stabilizer all as specified and directed .
Supply &fixing in replacement of lead acid battery 12Volts 180 AH of existing type & size suitable for Gen sets 15 to 125 KVA.Make EXIDE/AMRON inculding initial charging complete.
M&L for preparation of old painted surface of Servo Voltage stabiliser by scrapping / removing old paint , dirt etc, and spray painting with two coats of blue synthetic enamel paint over a coat of primer including writing of MES / SM No of capacity 15 KVA all as specified and directed by Engineer-in-charge .
Supply,installation and testing for maintenance free grounding(earthing) system complete burried directly in ground vertically (earth pit not less than ten feet below ground level) by making bore hole of 100 mm dia for inserting one number 17 mm dia molecular copper bonded high tensile low carbon steel circurlar earth electrode of 3 meter length with average copper thickness of 100 microns alongwith environmental friendly grounding enhancing compound and heavy duty (HDPE) PVC pipe cap all in below ground level and connected to copper strip 25mm x 3 mm flat by means of brass metal bolts , nuts and washers etc including protection pipe of GI 15 mm bore Medium grade upto 7.5 meter length and connection of earth lead to maintain distribution/LT panel board/DG set with copper lugs complete all as specified and directed by engineer in charge.(Note : Rate for necessary earth work ,PVC pipe,copper strip and all materials supplied by the contractor is deemed to be included in quoted rate of item).
Supply, laying and testing in replacement of ( FRLS) XLPE insulated PVC sheathing (heavy duty) armoured cable with aluminium conductor for working pressure up to and including 1100 volts to IS -7098 (Part-I) of size 70Sqmm x 3.5 Core.
All as per item No. 79 but of size 95Sqmm X 3.5 Core.
All as per item No. 79 but of size120 Sqmm X 3.5 Core.
M&L for cutting of hardstanding /road by mannual method upto.45 m width 15 Cm deep for inserting GI pipe 50 mm dia Medium grade for cable protection complete including making good surface with 1:2:4 mix Cement concreate all as specified and as directed by Engr-in-Charge.( Note : Rate of GI pipe is demed to be included in the quoted rate of item).
Supply,installation, commissioning and testing in replacement of factory made cubical type floor mounted out door panel weather proof fabricated out of with MS Sheet 16 SWG and angle iron frame ( 50x50x6mm) provn of front and rear door shutter with locking arrangment complete duly painted with powder coated paint over one coat of primer, provn of PCC foundation as directed by Engineer-in-charge complete comprising of following:- (a) Bus bar chamber of 3 phase 4 strip 415 volts with 250 Amps copper strip 1 set (b) MCCB 4 pole in coming 200 Amp 35 KA with earth fault reley -02 Nos (c) MCCB 4 pole out going 100 Amp 25 KA = 04 Nos (d) MCB SPN 63 Amp - 01 No (e) Voltmeter 0-500W volt - 01No (f) Amp meter 0 -200 Amp - 01No (g) Indicator lamp yellow , Red , blue (h) Complete wiring
Supply and install commissioning and testing in replacement of factory made cubical type floor mounted out door panel weather proof fabricated out of with Mild steel Sheet 16 SWG and angle iron frame ( 50x50x6mm) provn of front and rear door shutter with locking arrangment complete duly painted with powder coated paint over one coat of primer, provn of PCC foundation as directed by Engineer-in-charge complete comprising of following: (a) Bus bar chamber of 3 phase 4 strip 415 volts with 400Amps copper strip 1 set (b) MCCB 4 pole in coming 400 Amp 35 KA with earth fault reley -01 No (c) MCCB 4 pole out going 100 Amp 25 KA = 04 Nos (d) MCB SPN 63 Amp = 01 No (e) Voltmeter 0-500W volt = 01 No (f) Amp meter 0 -200 Amp = 01 No (g) Indicator lamp yellow , Red , blue (h) Complete wiring
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr depth and n.exc 1.5 mtr wide for laying of pipes/cables etc and getting out all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed by the Engineer-In-Charge.
M&L for sand cushioning (dry sand) to underground cable for cable protection laid in trenches / in existing cable ducts complete all as specified and as directed by the Engineer-In-Charge
M&L for brick, Sub class 'B' well burnt, laid dry flat in trenches for protection of cable over HT cable complete all as specified and as directed by the Engineer-In-Charge.
Supply & fixing in replacement of cable jointing kit and testing complete for 1.1 kv grade cable for Indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm.
Supply & fixing in replacement of cable jointing kit and testing complete for 1.1 kv grade cable for Indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm.
Supply and fixing and connecting in replacement of on load change over switch TPN 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material complere all as specified and directed.
S&F for flexible fuel hose pipe suitable for 200KVA DG set installed at CPRU, colour lab and UGBO including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 125KVA DG set installed at tech pump house, old pinto park pump house and RV area pump house including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 70KVA DG set installed at old domestic pump house including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 70KVA DG set installed at new domestic pump house including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 50KVA DG set installed at MAP pump house and old pinto park including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 50KVA DG set installed at CPRU pump house including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 40KVA DG set installed at STP pinto park and new STP including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 35KVA DG set installed at MT Astha pump house including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 35KVA DG set installed at MAP pump house Camp area including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 15KVA DG set installed at 1AFSR borewell including dismantling of existing pipe.
S&F for flexible fuel hose pipe suitable for 15KVA DG set installed at Maude line borewell including dismantling of existing pipe.
J.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .