Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC C O VAUDE VILLE HARDWARE OPP IOC DZUVURU KOHIMA NAGALAND 797 001 | KOHIMA | KOHIMA | NAGALAND | 797001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹9.1 L+₹29,967.70 (3.39%)Rejected-Finance C O HILL HARDWARE STORE P R HILL KOHIMA NAGALAND | PHEK | NAGALAND | 797104 | L2 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹8.8 L
EMD Value
₹17,700
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Zakhama
C/o 792 FPO PIN-900792 C/O 99 APO
PROVN OF FALSE CEILING IN BLDG NO T-354, T-361, T-362 AND T-363 AND PROVN OF STATIC TANK NEAR BLDG NO T-594 AT ZAKHAMA MILITARY STATION UNDER AGE (I) ZAKHAMA
2024_MES_662156_1
8301/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Zakhama
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Zakhama
₹17,700
28 Sept 2024
28 Jun 2024
6 Sept 2024
28 Jun 2024
3 Sept 2024
12 Jul 2024
Amount
Excavation over area, n. exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as "Supply only".
Supply only integral water proofing compound complete all as specified and as directed. Note:- Dose of WPC shall be as per manufacturer instruction and the same shall be recorded in the MB.
M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile over screed bed of 15 mm thick in cement mortar (1:4) complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Hard/ Dense soil complete all as specified and as directed.
M&L for hardcore with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed.
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough, lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, etc. including necessary formwork (straight or curved) complete all as specified and as directed.
M&L for pre polished chequered cement concrete tiles in floor, area of size 20cm x 20xm x 25mm thick with white cement and pigments of approved make jointed with cement slurry and pointed with white cement mixed with colour pigment to match with the tiles over screed bed of 15 mm thick in cement mortar (1:4) complete all as specified and as directed.
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
S&F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylone sleeves and screws at 450mm centre to centre/ intermidiate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasterners with and inculding ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermidiate channel with connecting clips across the intermidiate channel at 457mm centre to centre including 4mm thick non asbestos fibre cemet building boards fixed/laid to GI frame work and applying two coats of oil bound distemper complete all as specified and as directed.
M&L for Timber framed and fixed clean sawn 2nd class hard-wood in scantling fixed complete.
M&L including preparation of new or previously untreated surface and treating with two coats of synthetic enamel paint over a coat of pink primer to new wood and wooden surface exceeding 10cm width or girth complete all as specified and as directed.
Cutting & Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) of dia 40/50 mm, complete all as directed.
M & L for 25 mm bore three layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in walls/floors/trenches. incl necessary connection from existing pipeline etc, complete all as specified and directed. (Note : Necessary earthwork shall deemed to be incusive in the quoted rate.)
S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron/PPR pipe and fixed of 25 mm dia, complete all as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed multistranded copper conductor FRLS cable of size 1.5 Sqmm nominal area 1100 volt grade drawn through and including PVC casing-capping/conduit (medium grade) of suitable size with all fittings and accessories including PVC board with cover of suitable size for housing/mounting the switches/socket etc including 1.5 Sqmm PVC insulated unsheathed single core copper conductor as earth continuty wire connected to common earth dolly for one light/exhaust fan point control by one switch.one way compleate all as specified and directed.
S&F 4 way, SPN 240V double door DB when MCB to be used with 200 Amps bus bar complete all as specified and directed.
S&F 32 Amps, miniature circuit breaker (MCB) SPN/DP rating 240V, 10KA 'C' curve, in the MCB DB complete with connection testing and commissioning complete all as directed.
S&F SP, 6-32 Amps, miniature circuit breaker (MCB) 240V, 10KA 'C' curve, in the MCB DB complete with connection testing and commissioning complete all as directed.
S&F submain wiring 2X 2.5 sq mm along with earth wire 1X 2.5 sq mm FRLS PVC insulated copper conductor, single core in surface drawn in and including casing capping with fixtures and , complete all as specified and directed. Note:- Two run of 2.5 Sqmm main wire and One run of 2.5 Sqmm earth wire measured as one unit.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.,complete all as specified and directed.
S&F switch piano flush button single pole one way 5 amps.complete all as specified and directed
thepfuralie zutso (BID ID -3069714)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .