Loading…
Loading…
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
8 Jun 2026, 6:00 pm3d left
Executive Engineer (Electric)
PWD CAMPUS BHARATPUR
Electrical Utility Shifting and Street Light Pole work from Chouth Ka Barwara Bus Stand to Prem Mandir Distt Sawai Madhopur
2026_CEPWD_563841_1
NIT-03-2026-27
Open Tender
Electrical Works
90 days
Sawai Madhopur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
As per NIT
₹70,000
Yes
Bharatpur
31 May 2026
31 May 2026
9 Jun 2026
31 May 2026
8 Jun 2026
31 May 2026
3 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply and fixing of 11 KV Outdoor 4 way feeder pillar Box confirming to Discom specifications and made of 3.15 mm thick powder coated CRCA sheet enclosure confirming to IS 14772/IEC 60670 (1989) of Size 1000 mm x 1000 mm x 1500 mm, Both front and rear doors should have 3 heavy duty M.S. hinges with Brass pin inserted inside and locking arrangements.The bottom foundation frame stand should be made from 65x65x6mm MS Angle with four legs of 200mm height provided with 150x150x6mm flats grouted with C.C. of M-10 grade to achieve the height of 2.0 feet above the road level suitable for four outgoing. | 1 | Each | - | - | BI01010001010000000000000515BI0100001113 |
| 2 | Supply and fixing of LT Distribution Kiosk confirming to IS:13947/1993/ IEC 60947 Pt.3 amended up-to-date and as per DISCOM specifications made of 2 mm thick powder coated CRCA sheet of 415 volts 3 phase 4 wire triple pole and neutral type, complete in all respect as required. Including Incoming Switch Disconnector Fuse unit, Aluminium Busbar with copper one piece U contacts base, brass studs and nuts, copper busbar for main and interconnection, MS Channel frame of 75 mm x 40 mm grouted with C.C. of M-10 grade to achieve the height of 1.5 feet above the road level suitable for required no. of outgoing. | - | - | - | - | BI01010001010000000000000515BI0100001114 |
| 3 | 200 Amp. LT Distribution Kiosk for 63/100 KVA Transformer | 3 | Each | - | - | BI01010001010000000000000515BI0100001115 |
| 4 | 100 Amp. Distribution Kiosk of Size 500mm x 550 mm x 700 mm suitable for Underground cable | 3 | Each | - | - | BI01010001010000000000000515BI0100001116 |
| 5 | Labour charges for Dismantling the structure with pole mounted transformer of different capacity along with distribution boards and re- erecting the transformer on newly erected structure along with distribution boards and including testing and commissioning (as well as cabling connection complete as required) | 2 | Each | - | - | BI01010001010000000000000515BI0100001117 |
| 6 | Labour charges for dismantling of existing PCC/MS electrical Pole including MS channel, V cross arm, 11KV insulator, LT insulator, guard wires, stay wires, one span of ACSR conductors and other electric items, coming along and in the alignment of the road, then removal and re-rolling of the PCC /MS Pole as well as other materials and handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and as per the direction of Engineer Incharge, clean the site good as per the requirement and dismantle material receipt duly signed by DISCOM Engineer submit the receipt to EIC as required. | 2 | Each | - | - | BI01010001010000000000000515BI0100001118 |
| 7 | Labour charges for dismantling of existing street light electrical pole with street light fixture, underground cable, MS box and other electric items of the pole coming along and in the alignment of the road, then removal and re- rolling of MS/PCC pole of different sizes as well as other materials and handing over the same to DISCOM/UIT/MC store and as per the direction of Engineer Incharge and clean the site good as per the requirement and submit the receipt from concering authority complete as required. | 20 | Per Pole | - | - | BI01010001010000000000000515BI0100001119 |
| 8 | Labour charges for dismantling of service line connection (weather proof cable/armoured cable) for single phase /three phase supply of industrial/domestic connections from existing PCC/MS pole and handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and provide temporary supply to domestic/industrial connections to the consumer where supply is disconnected and clean the site good as per the requirement and direction of Engineer Incharge complete as required. | 30 | Job | - | - | BI01010001010000000000000515BI0100001120 |
| 9 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. | - | - | - | - | BI01010001010000000000000515BI0100001121 |
| 10 | 185.0 Sq. mm | - | - | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.63 MB
BOQ_1003570.xls
BOQ • 0.37 MB
Conditions.pdf
Tender Documents • 5.64 MB
Annexure.pdf
Other Document • 1.72 MB
UtilityShifting.pdf
Additional Documents • 6.07 MB
Download all tender documents and submit your bid