Superintending Engineer, EDC, Hapur
Superintending Engineer, EDC, Hapur
Various line works in Business Plain in area of EDD-Garh
2020_PVVNL_492425_1
09(W)/EDCH/2020-21
Open Tender
Electrical Works
Lump-sum
Hapur
Various line works in Business Plain in area of EDD-Garh
3 documents required · 3 mandatory
₹1,180
SE, EDC, Hapur
₹3,500
30 Jul 2020
13 Jul 2020
27 Jul 2020
13 Jul 2020
27 Jul 2020
13 Jul 2020
13 Jul 2020 - 27 Jul 2020
180 days
Amount
¼1½ 33@11 ds0oh0 midsUnz miSMk ls iksf”kr xzke jlwyiqj esa Jh v’kksd iq= Jh xaxkizlkn ds uydwi ij j[ks 25 ds0oh0 ifjorZd yxkus dk dk;Z ¼2½ 33@11 ds0oh0 midsUnz miSMk ls iksf”kr xzke miSMk esa Jh egkohj flag ds futh uydwi ij LFkkfir 63 ds0oh0,0 dh 100 ds0oh0,0 ls {kerko`f) djus dk dk;Z ¼3½ 33@11 ds0oh0 midsUnz miSMk ls iksf”kr xzke dfu;k esa 59 ,l0ch0th0 ij LFkkfir 25 ds0oh0,0 ifjorZd dh 63 ds0oh0,0 ls {kerko`f) djus dk dk;Z ¼4½ xzke >Mhuk esa orZeku esa LFkkfir 160 ds0oh0,0 ifjorZd vfrHkkfjr gksus ds dkj.k 100 ds0oh0,0 dk vfrfjDr ifjorZd LFkkfir djus dk dk;Z ¼5½ 33@11 ds0oh0 midsUnz flEHkkoyh ls iksf”kr xzke fl[kSMk esa rkykc ij LFkkfir 100 ds0oh0,0 ifjorZd dh vfrHkkfjrk ds dkj.k 100 ds0oh0,0 vfrfjDr tksMk cukus dk dk;Z ¼6½ 33@11 ds0oh0 fo|qr midsUnz miSMk esa 50ug ds tksMs ij LFkkfir 63 ds0oh0,0 ifjorZd dh vfrHkkfjr gksus ds dkj.k {kerk o`f) 100 ds0oh0,0 ifjorZd LFkkfir djus dk dk;Z ¼7½ 33@11 ds0oh0 midsUnz x< izFke ls iksf”kr xzke nkSrkbZ esa dfczLrku ds ikl LFkkfir 63$100 ds0oh0,0 dk ifjorZd vfrHkkfjr gksus ds dkj.k {kerko`f) dj 250 ds0oh0,0 djus dk dk;Z ¼8½ 33@11 ds0oh0 midsUnz nfRRk;kuk ls iksf”kr 11 ds0oh0 eqckjhdiqj QhMj esa xzke eqckfjdiqj ds taxy esa xaxklju ds [ksr esa lkfo=h nsoh ds [ksr rd 11 ds0oh0 ykbZu esa ttZj ohty rkj dks u;s ohty rkj ls cnyus dk dk;Z ¼9½ 33 ds0oh0 midsUnz jeiqjk ls iksf”kr xzke uyh gqlSu esa Jh uhVw ‘kekZ ds [ksr ls xqtj jgh ttZj ,y0Vh0 ykbZu cnyus ,oa yEcs LiSuksa ds chp esa iksy yxkus dk dk;Z ¼10½ 33@11 ds0oh0 fo|qr midsUnz yksnhiqj ls iksf”kr 11 ds0oh0 <kuk QhMj esa xzke <kuk ds taxy esa xqjuke dkSj o xqMMw ds tksMs rd ttZj th0 vkbZ0 rkj dks ohty rkj ls cnyus ds dk;Z ¼11½ 33@11 ds0oh0 fo|qr midsUnz eqjknuxj QhMj dk Hkkj 33@11 ds0oh0 fo|qr midsUnz jeiqjk ls iksf”kr 11 ds0oh0 gkthiqj QhMj ij LFkkukUrfjr djus dk dk;Z ¼12½ 33@11 ds0oh0 midsUnz x<+ izFke ls iksf”kr xzke vYYkkc[‘kiqj esa 23 ds0Vh0ch0 ds ikl LFkkfir 100 ds0oh0,0 ifjorZd dh vfrHkkfjrk de djus gsrq vfrfjDr 100 ds0oh0,0 tksMk cukus dk dk;Z ¼13½ 33@11 ds0oh0 midsUnz x<+ izFke ls iksf”kr xzke vYYkkc[‘kiqj esa ckxMiqj jksM ij LFkkfir 100 ds0oh0,0 ifjorZd dh vfrHkkfjrk de djus gsrq vfrfjDr 100 ds0oh0,0 tksMk cukus dk dk;ZA (All works will be completed as per sanctioned estimate concerned).
Carriage of line material (Like-Cross Arm, All type Clamps, Nuts & Bolts, ACSR Conductor, Jointing Kit, XLPE Cable etc.), from Electricity Store Center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road.
Carriage of PCC Pole 8.5mtrs long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road.
Carriage of following from Electricity store center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road.
Erection & Fixing of PCC Pole 8.5 mtr. long in 11 KV line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts.
Erection & fixing of PCC pole 8.5 mtr. in L.T. Line after digging of suitable pits including fixing of all accessories by providing L.T. Pin Clamp made of M.S. Flat of size 50x6mm & Shackle Insulator of size 90x75 mm & proper size nuts and bolts as per RESPO Drawing/Norms.
Fabrication, erection and fixing of double pole on PCC Pole 8.5 mtr. long with fixing of M.S. Top & Dropper Channel, M.S. S/S Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting as per RESPO Drawing/Norms by providing top and dropper clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts.
Mounting, Placing and connecting from LT/HT side of 11KV, following T/F as per RESPO Norms.
Fabrication & Fixing of T-Channel on pole by providing Holding Clamps, F-Clamps & Proper size nuts & bolts, as per RESPO/Norms.
Laying , Stringing and final sagging of ACSR weasel conductor after binding from Insulator as per RESPO/Drawing Norms.
Laying , Stringing and final sagging of ACSR Rabbit conductor after binding from Insulator as per RESPO/Drawing Norms.
Laying , Stringing and final sagging of ACSR Dog conductor after binding from Insulator as per RESPO/Drawing Norms.
Laying of ABC Conductor (3x120+1x95+1x16) Sqmm and completion work properly as per RESPO/Norms
Laying of LT PVC Cable and completion work properly as per RESPO/Norms.
Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops.
Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts.
Grouting of following supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials.
Erection & Fixing of Distribution Box on pole by provding 02 Nos. D/B Clamps & proper size nut & bolts.
Providing & Fixing of Peircing Clamps.
Providing & Fixing of Suspension Clamps with Eye-Hook.
Providing & Fixing of Eye-Hook.
Providing & Fixing of Dead End Clamps with Eye-Hook.
Safely Dismantling & Removal of following T/F at old D/P and opening of all accessories.
Removal of Old & used/Scrap Acsr weasel Conductor from insulator and opening of all accessories and bundling the same.
Removal of Old & used/Scrap G.I. Wire from insulator and opening of all accessories and bundling the same.
Carriage of old & used/scrap ACSR weasel Conductor and G.I. Wire (780+1378 mtrs and as per sanctiond estimate), from site of work to Electricity Store Center, Hapur/JE Store with loading and unloading at both ends on Kachha Packka road.
Carriage of old & used 25KVA T/F from site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road.
Jumpering work properly as per RESPO/Norms.
S.K Electricals
A.A.ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .