Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC STANDS L1 | |
| 2 | L2₹6.3 L+₹27,365.05 (4.55%)Rejected-Finance | L2 | Rejected-Finance L2 BIDDER | |
| 3 | Rejected-Technical | - | Rejected-Technical PQC not qualified |
Tender Value
₹5.7 L
EMD Value
₹11,400
Closing Date
10 Jul 2019, 6:00 pmClosed
SE OMCIII BTPS OBRA SONEBHADRA
OFFICE OF SE OMCIII BTPS OBRA SONEBHADRA
Annual Maintenance of Battery Battery Chargers DC Lub Oil DC Seal DC Scanner Fan Panels Cranes etc of 5 into200MW Units BTPS Obra
2019_RVUNL_345569_2
T 2/O MC III/EMD III/BTPS/2019 20
Open Tender
Electrical Works
Lump-sum
365 days
BTPS OBRA SONEBHADRA
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Dy CAO CFA and BO BTPS OBRA SONEBHADRA
₹11,400
31 Mar 2020
3 Jul 2019
12 Jul 2019
3 Jul 2019
10 Jul 2019
3 Jul 2019
3 Jul 2019 - 10 Jul 2019
Amount
SECTION A___Overhauling, cleaning & reconditioning of 220VDC 1000Ah unit/ station batteries
Overhauling, cleaning & reconditioning of 220VDC 400Ah switchyard batteries
Overhauling, cleaning & reconditioning of 50VDC 300Ah annuncition batteries
Overhauling, cleaning & reconditioning of 48VDC 500Ah carrier communication batteries
Load test of 220VDC 1000Ah unit/ station batteries
load test of 220VDC 400Ah switchyard batteries
Load test of 50VDC 300Ah annuncition batteries
load test of 48VDC 500Ah carrier communication batteries)
Complete overhauling, Fault rectification, cleaning and reconditioning of Battery Chargers for Annunciation/ Carrier/ Switchyard of 5x200MW
Complete Overhauling, Fault rectification, cleaning and reconditioning of 220V DC distribution board of Units/Station of 5x200MW).
Overhauling, cleaning and reconditioning of DC Lube Oil / DC Seal Oil/DC Scanner Fan Panels of Units of 5x200MW
Overhauling, cleaning and reconditioning of 50V DC annunciation distribution board panels of two units of 5x200MW
Complete overhauling, Fault rectification, cleaning and reconditioning of rectifier based Battery Chargers for Unit/Station of 5x200MW
Checking and Filling of Demineralised water in Unit ,Station, Switchyard ,Annunciation, UPS, Carrier Communication Batteries IN 5x200 MW UNITS as per direction of AE/JE (Once in three months)
Repairing ,testing, calibration work of KW/MW/PF/Ammeter/Voltmeter/frequency meters of battery chargers, Dg sets &compressors
Repairing ,testing, calibration work of Power supply modules AC/DC 220VAC/48VDC/24VDC of battery chargers, Dg sets &compressors
SECTION B____Complete overhauling, cleaning and reconditioning of LT Modules of unit cranes-03 nos. (2Nos.-120/20T, 1No.- 75/15T) - main hoist
Complete overhauling, cleaning and reconditioning of LT Modules of unit cranes-03 nos. (2Nos.-120/20T, 1No.- 75/15T) - Auxiliary hoist.
Complete overhauling, cleaning and reconditioning of LT Modules of unit cranes-03 nos. (2Nos.-120/20T, 1No.- 75/15T) - cross travel
Complete overhauling, cleaning and reconditioning of LT Modules of unit cranes-03 nos. (2Nos.-120/20T, 1No.- 75/15T) - long hoist
Complete overhauling, cleaning and reconditioning of LT Modules of unit cranes-03 nos. (2Nos.-120/20T, 1No.- 75/15T) - protective panel
Complete overhauling, cleaning and reconditioning of LT Modules of CW Pump House Crane-02 nos. (15T each) - main hoist
Complete overhauling, cleaning and reconditioning of LT Modules of CW Pump House Crane-02 nos. (15T each) - cross travel
Complete overhauling, cleaning and reconditioning of LT Modules of CW Pump House Crane-02 nos. (15T each) - long travel
Complete overhauling, cleaning and reconditioning of LT Modules of CW Pump House Crane-02 nos. (15T each) - protective panel
Cleaning , Repairing and O/H of 0.4kv Busbar and replacement of faulty insulators of 0.4 KV unit Bus
Cleaning , Repairing and O/H of 0.4kv Busbar and replacement of faulty insulators of 0.4 KV cw pump house Bus(inside)
Cleaning , Repairing and O/H of 0.4kv Busbar and replacement of faulty insulators of 0.4 KV cw pump house Bus(outside)
Alignment of 0.4KV main supply bus bar of E.O.T. Crane of unit/cw pump house in case of emergency fault
Cleaning , Repairing and O/H of Aux. bus bar -unit
Cleaning , Repairing and O/H of Aux. bus bar -cw pump house
Replacing the damaged/broken backelite plates & flexible current collectors lead of motor circuit of unit/cw pump house
Dismantling, replacement of faulty/ damaged flexible cable of size upto 35 Sq. mm of Unit crane/CW pump house crane (01 no. )- making end joint and connecting to panel as per the directive of AE/JE
Fault rectification/Cleaning & Servicing of Local panels of Instrument Air Compressor=9 nos , New Compressor-04 nos., auto panels=2 Nos. & Air Drier-03 nos.
Cleaning & Servicing of Auto load sharing panel-01 no. & Local panel of DG Set No. 1,2,3& 4, Total-05 nos, twice in a year
Complete rewinding & repairing of self starters Lucas make of DG sets &Diesel fire pumps
M/S ACCURATE ENGINEERING
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .