| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 CrAccepted-AOC | ₹23.3 Cr Quoted ₹23.4 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹23.5 CrRejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹23.5 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹24.0 CrRejected-Finance | ₹24.0 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹24.1 CrRejected-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹24.1 Cr | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹24.1 CrRejected-Finance PLOT NO 65 SECTOR 18 OPP HIPA SARHAUL GURUGRAM 122 001 | ₹24.1 Cr | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹24 Cr
EMD Value
₹15 L
Closing Date
19 Apr 2023, 6:00 pmClosed
CHIEF ENGINEER CG GOA
HQ CE CG GOA BOGMALO 403806
PROVISION OF DEFICIENT MARRIED ACCOMODATION FOR OFFICERS AT DHQ-4 KOCHI
2023_MES_586587_1
82038/E8
Open Tender
Civil Works
720 days
KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE I CG KOCHI
₹15 L
Yes
23 May 2023
21 Mar 2023
21 Apr 2023
21 Mar 2023
19 Apr 2023
12 Apr 2023
Amount
SCHEDULE ‘A’ PART-I (BUILDING & STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( EXCAVATION AND EARTH WORK ) /SITE CLEARANCE Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (DEMOLITION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (ROAD/ PATH/ CULVERT/ HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (COMPOUND WALL & STEEL GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (EXTERNAL ELECTRIFICATION)) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (AVAITION OBSTRUCTION & LIFT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
PILE FOUNDATION: Boring for bored cast in situ pile 800 mm dia through any depth of any type of soil, clay, and getting out & disposal of spoil to any distance outside of MD land and depositing at a place as directed by the Engg In Charge using DMC method (Direct Mud Circulation)
Boring for bored cast in situ pile 900 mm dia through any depth of any type of soil, clay, and getting out & disposal of spoil to any distance outside of MD land and depositing at a place as directed by the Engg In Charge using DMC method (Direct Mud Circulation)
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length/any sections as shown on drg as in bored pile etc complete all as specified and directed.
Reinforced cement concrete of grade M-30 design mix (RMC) as per IS-456 with using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg (Note:- Reinforcement will be measured and paid for seperately under relavent items of this schedule)
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D).
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10mm dia and over conforming to IS-1786 as Helical/stirrups for piles cut to length, bent to shape required, and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D).
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps/ grade beams all as shown on drgs including cut to length, bend to required shape, cranking/ hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs (Fe-500D).
Providing TMT bars (CRS/HCRM/CRM) in reinforcement 5 mm dia and over up to and including 10mm dia conforming to IS-1786 as stirrups for pile caps/ grade beams cut to length, bent to shape required, and binding with mild steel wire (annealed) not less than 0.9mm dia or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs (Fe-500D).
M&L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed.
Formwork to sides of pile caps/ grade beams rough finished surface of concrete flat all as specified and as directed.
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 800 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid seperatly)
M&L for carrying out Initial (lateral load test) cast in situ piles of 800 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid seperatly)
M&L for carrying out Initial load test ( pull out test) of cast in situ piles of 800 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid seperatly)
M&L for carrying out Initial Load test (vertical load test) cast in situ piles of 900 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid seperatly)
M&L for carrying out Initial (lateral) load test cast in situ piles of 900 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid seperatly)
M&L for carrying out Initial load test ( pull out test) of cast in situ piles of 900 mm dia as per IS 2911 (Part 4) including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid seperatly)
M&L for carrying out Routine Load test (verticle load)all as per IS 2911 (Part 4) 2013 for 800 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
M&L for carrying out Routine Load (verticle load) all as per IS 2911 (Part 4) 2013 for 900 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
M&L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 800 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
M&L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 900 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.
INTERNAL WATER SUPPLY: Supply and fixing 15mm Health faucet with wall hook Make: Hindware Model No F160027 or equivalent complete all as specified & directed
Supply & fixing 15 mm dia Jaguar make 2 way bib Tap ( Fancy type) or equevlent cast copper alloy with crutch or butterfly handle screwed down screwed for Iron/ CPVC pipes complete all as specified.
INTERNAL ELECTRIC SUPPLY S & F energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. (Model : Efficiencia prime of Havells or equivalent approved make)
S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S&F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No.TRANS AIR 12" or equivalent model of Usha, Havells or BAJAJ
S & F Vertical triple pole & neutral, double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP MCCB (measured and paid seperately) as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed.
Supply, Installation, Testing and Commissioning of 1-Phase, 2-wire, 240V, Class 1.0 Smart Energy Meter, BIS marked IS-16444, at the rating of 5-30A suitable for Prepaid/Postpaid mode with Polycarbonate Meter Box. The Smart Meter shall support the following minimum basic features: Measurement of electrical energy parameters; Bidirectional Communication; Integrated Load limiting /connect/disconnect switch; Tamper event detection; recording and reporting; Power event alarms; Remote firmware upgrade; TOD features; On demand reading. Meter shall have the ability to communicate with Head End System (HES) on RF Communication technology mentioned in IS16444 Part 1 in a secure manner. Data exchange protocol from smart meter to HES shall be based on open protocol like TCP/lP or DLMS/COSEM. RF network should use 865-867 MHz frequency band as permitted by WPC complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. Make: GHWCARTWH025 of Havells or equivalent in Bajaj, Crompton, Recold complete all as specified and directed.
Supply, installing, testing & commissioning of Cloud-Hosted multiuser web-based software with 2-years defect-liability period with following modules: (i) Head End System (HES): to acquire meter data automatically from DCUs and monitor parameters acquired from meters. (ii) Meter data management Modules : The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data. (a) 30min instantaneous data from all the meters for seven parameters - cumulative energy , Power, Current , Voltage, Power factor and frequency. (b) Monthly and quarterly billing survey data for cumulative energy and max demand. iii) Billing Module : The billing module would collect the data from the meter data management module, calculate billing determinant and make energy data / billing data available to admin and end user. There should be provision for entry of change in the tariff structure by the MES staff as decided time to time. (iv) Occupation and Vacation module: The system would supportoccupation/vacation based on the unit categories. (v) Website: There would be a dedicated website for AGE/GE and BSO team to view all the data and information along with customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (Androi and iOS based) for admin use complete all as specified and directed.
Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph). It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY: Cutting bituminous road/ PCC path way/or any other indicated direction , not exceeding to a width of .5 mtr and not exceeding to a depth of 0.5 mtr, laying pipe for UG Cable protection or water supply pipe and refilling with the excavated material, watering and well ramming in layers and finishing with 1:3:6 PCC up to a thickness of 100 mm, removing the surplus material away from the site, all as specified and directed by the Engr-in-charge.
M & L for cutting / welding/ fabricating, Installation , Testing and commissioning of LT control panel indoor type having provision of extra double door openings into two with rubber beadings cubical type of suitable size, made out of 3.15 mm CRCA sheet compartmentalized with rubber beadings, angle iron 50 x 50 x 6 mm shall be used for making legs/ frame, duly powder coated internally and externally, including provn of Aluminium Busbar, Bus Bar chamber shall be provided with inspection covers, inclined louvers for air circulation, bottom cover shall have provision for fixing and including suitable cable glands of required size and as per specifications of LT Cable entry, each MCCB, Change over, Bus Bar chambers, measuring instruments, prewired shall have independent openings. Including provn of PCC Platform of suitable size PCC 1:2:4 all as directed by the Engineer-in-charge. The LT Panel comprising of the following:- Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 500 Amps for phases and 500 Amps for Neutral. Incoming:-Incommer :- MCCB 4 pole 250 Amp, 36 KA - 01 No Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. ( c)CT's - 250/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, breaking capacity 36 KA- 01 No. (b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 25 KA- 01 No. (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 18 KA- 01 No. Make of MCCB:- Havells/L&T/Indo Asian/ equivalent.
All as per item No. 15.33 but with the following accessories:- Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 250 Amps for phases and 250 Amps for Neutral. Incoming:- (a) MCCB 4 pole,415 Volts, 63 Amps, breaking capacity 25 KA- 01 No Metering Unit:- (a) R Y B Indications (LED Type) - 1 sets (b) Digital Multi function meter - 01 No. ( c) CT's - 63/5A, CL-1,15 VA - 1 set Outgoing:- (a) MCB, TPN, C curve, 32 Amps, 415 volts 10 KA- 03No. (b) MCB, SPN, C curve, 16 Amps, 240 volts 10 KA- 01 No. (c) MCB, SPN, C curve, 10 Amps, 415 volts 10 KA- 01 No.
Supply and fixing of MCCB, thermal magnetic release, 4 pole, 415 Volts, 250 Amps, breaking capacity 35 KA, Ics =100% Icu with standard sheet metal enclosure, powder coated, siemens grey colour and fixing complete with suitable clamp/fixing arrangement all as specified and directed by Engr-in-charge.
Supply and fixing ofMCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA, Ics =100% Icu with standard sheet metal enclosure, powder coated, siemens grey colour and fixing complete with suitable clamp/fixing arrangement all as specified and directed by Engr-in-charge.
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 25 x 4 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply, installing, testing and commissioning of electrically driven Centrifugal Pump set as per specification, motor TEFC type, 2900 rpm, 420 V, 50 Hz, 3 ph, class 'F' insulation, IP 55 protection, 5 HP, starting on suitable DOL starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller(as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 450 LPM at 36 mtr head inclusive of suitable rated 3 ph starter as recommented by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge. Make:- Kirloskar Brothers/ equaivalent. NOTE: (a) Materal and labour for required length of suction pipe, GI heavy duty, flanged type, suitable for the suction side of pump including valve on suction side and recommended size of foot valve with accessories complete. (b) Materal and labour for required length of delivery pipe, GI heavy duty, flanged type, suitable for the delivery side of pump including NRV with accessories complete. (c ) Pressure gauge diaphram type up to 50 kg/sq.cm- 1 No.
M & L for valve chamber and provision of new masonary valve chamber of size 1200x1200x1200mm solid block masonary 200 mm thick over concrete foundation in PCC 1:4:8 D2 100 mm thick,50 mm thick PCC 1:2:4 type B1 in coping including 15 mm thick plastering in cement motor 1:4 for internal surface 15 cm below normal ground level with MS sheet 3.15 thick hinged MS cover with locking arrangements. Lifting handle fitted to 50 X 50 X 6 mm angle iron frame and painting including necessary earth work complete all as specified and directed.
Supply and fix Cast iron Air Valves with single air outlets,confirming to IS 14845 of size 80 mm dia bore and fixing up in Cast iron water supply mains of size 80mm dia complete all as specified and directed.
FIRE FIGHTING: Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed.
Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM all as specified and directed by Engr-in-Charge. Make: SIEMENS/NOTIFIER/BOSCH
S&F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours (Cat No LSSR5W Make CG or equivalent to Bajaj/havells.
Supply, installation testing and commissioning of XLPE insulated electric cable with copper coductor of size 1.5 sq.mm, 2 core suitable for working pressure 1100 Volts to IS:7098 and drawn into PVC coduit pipe 20 mm. all as specified and directed.
Supply and install LT control panel floor mounting type fabricated from 3.15 mm thick CRCA sheet, powder coated dust and vermin proof complete with separate compartments for main and standby supplies including Al bus bar of capacity 100A, and with following accessories:- (a) MCCB TPN 63 Amps 4 pole as incoming -1 No (b) MCB TPN 32 Amps "D" curve 10 KA - 1 Nos (c) DOL starter - 01 Nos (d) Multifunction meter - 01 (e) Phase indicating lamps R, Y, B - 1 Set (LED type)
S & F fire extinguisher dry chemical powder (ABC) type (IS:15683) of capacity 4 Kg complete with installation brackets all as directed.
S & F fire extinguisher CO2 (light weight squeeze grip type) (IS:15683) of capacity 4.5 Kg complete with installation brackets all as directed.
SOLAR PV MODULES: (a)Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 10 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules shall be as per approved design parameters, with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 320/325 Wp with minimum 72 cells & efficiency not less than 17-19 %, conforming to IEC 61215, IEC 61730, IEC 61701 (b) Material and labour for Module Mounting structure (MMS) fabricted from pre-coated aluminium section of suitable size with specified tilt angle according to site requirement & Optimum angle to achieve Max benefit of solar energy and suitable to withstand 150 Kmph wind speed all as per approved design parameters and to match with the existing site conditions. Necessary roof treatment to avoid any sepage in future shall be carried out. (c) Supply, laying & Testing of DC cable minimum size 1x 4/1x6 sqmm multi stranded copper conductor (d) Supply, installation test and commissioning of junction boxes / SMBs for 10 KWp AC output all as per approved design & layout plan (e) Supply, laying & Testing of DC cable 2 runs minimum size 1x 4/1x6 sqmm (DC side) 4x16 sqmm copper unarmoured (for ac side) including suitable size of cable lugs, male & female MC4 connectors & joints etc (f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system.
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.5 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc.complete.
Supply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, LED of Bajaj cat No BGAV 302 LED , 240 V, with timer switch and one No 10 A, MCB, SPN 230 V fixed enclousre.
Soil Investigation including making necessary arrangement mobilisation and demobilisation for equipment tools and plant personnel etc required for soil investigation and their removal after satifaction completion of work in land including slushy areas etc complete comprising of following:- (a) Boring 150mm dia through all types of soil to a Depth Of 75 M (Maximum) (04 Nos bore holes)below the ground level collecting samples and conducting necessary field tests for pile foundation of dia 900mm, 800mm, 700mm, 600mm and 500mm. (b) Conducting all necessary laboratory tests on samples and submission of reports with suggestion on type of suitable foundation system including vetting by IIT/NIT/Govt Engineering college. Note : (i) Soil Investigation can be carried out only after demolition of existing building as catered in the relevant schedule. (ii) For details refer Particular specification clause Nos. 39.0
Outsourcing services for maning and operation of Lifts at Married accommodation for officers at DHQ-4 by employing 02 Nos qualified Lift Operator in two shifts (One operator in each shift i.e, two shifts in a day to operate, rescue in case of failure / emergency) including Sundays and holidays. Man power and Nos of lifts as given below for the entire system including cleaning and upkeeping of equipments and surroundings etc. complete all as specified and directed.Details of the Lifts are as follows for the 1st year:- (a) Passenger Lift of Capacity 544 KGs, 8 Passangers 9 stops and 9 landings - 01 No (at Married accommodation for officers at DHQ-4) (b) Passenger Lift of Capacity 884 KGs, 13 Passangers 9 stops and 9 landings - 01 No (at Married accommodation for officers at DHQ-4) Shift Details TRADEMAN: 01 Lift operator x 02 shift per day =02 Lift operator per day Total Shift = 02x334 =668 shift Shift Timings:- 1st Shift : 0600 Hrs to 1400 Hrs (01 Lift Operator) 2nd Shift : 1400 Hrs to 2200 Hrs (01 Lift Operator)
All as per item No 15.55 here in before but for 2nd year Note for Ser Item No.15.55 to 15.56:- (i) One qualified lift operator per each shift of 08 hrs as mentioned above shall be deployed including sundays and Holidays (with necessary releiver), accordingly the duty roaster to be submitted by the contractor before commencement of month. The rate quoted shall be deemed to be inclusive of wages of the reliever. (ii) The Contractor shall employ lift operators having recongnised qualification with adequate experience in similar nature of work. (iii) Manning & Operation of lifts shall start after completion/handing over of projects.
All as per item No.15.57 here in before but for Second year after expiry of defects liability period.
All as per item No.15.57 here in before but for Third year after expiry of defects liability period.
All as per item No.15.60 here in before but for Second year after expiry of defects liability period.
All as per item No. 15.60 here in before but for Third year after expiry of defects liability period. Note for Item No.15.57 to 15.62:- (i) Comprehensive maintenance of lifts shall be start after completion of defect liability Period of 2 years. (ii) Consumable items, cabin LED lamp of existing rating, Minor spares costing less than Rs 2000.00, etc. are deemed to be included in the over all rate quoted. (iii) Major spares required for maint of lift shall be measured and paid separately. (iv) Cleaning of Car, Shaft well, Lift Control Room, Replacement of Ground Mat, etc. shall be included in the over all rate quoted. (v) Replacement of all ceiling lights to LED lights, including replacement of Ceiling if required for fixing lights, etc. as directed by the Engineer-in-Charge shall be included in the over all rate quoted. (vi) Functioning of all emergency telephone service inside the Car and Control room including replacement of telephone if required shall be included in the over all rate quoted.
A2Z ENGINEERS AND PILE FOUNDATIONS
Rabina Enterprises Pvt Ltd
JAIN BUILDER
Varindera Constructions Limited
vijay infraprojects pvt ltd
Saru Enterprises Pvt Ltd
Komal Buildcon Pvt. Ltd.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid