Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 1ST FLOOR HYUNDAI SHOWROOM NEAR HARIAL CHOWK HISAR ROAD NARWANA JIND HARYANA 126116 UDYAM HR 08 0000499 | JIND | HARYANA | 126116 | ₹6.0 L | L1 | Accepted-AOC accepted |
| 2 | Rejected-Technical H NO 604A BLOCK A SUSHANT LOK 1 GURUGRAM HARYANA | GURUGRAM | GURUGRAM | HARYANA | - | - | Rejected-Technical rejected |
| Sl No | Description | Qty | Unit | 3S TECHNOLOGY INDIA L1 |
|---|---|---|---|---|
| 1.00HSR Items | ||||
| 1.01 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] | 1,000 | P.Metre | 53 ₹53,000 |
| 2.00 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 1,000 | P.Metre | 33 ₹33,000 |
| 3.00NS Items | ||||
| 3.01 | Supply, Installation, Testing and Commissioning of System Sensor Fire Alarm Control Panel 6 zone with the features of Support 16 x 2 Char LCD Display, Aesthetically designed Front Facia / LED`s, Individual Zone Isolation, Event Logging, Earth Fault Monitoring, Aux output facility, On board memory lock switch to prevent unauthorized panel configuration changes, Mechanical Keylock, Monitored NAC and Zone Circuit for Open / Short / Faults, Fire, Fault, Configurable Relay, Customizable text inserts, Input for remote reset/ evacuate/alert/fire, Lamp Test Facility, Fire, Fault, Configurable Relay, Certified for Safety standard. IEC 62368-1:2018, NAC Enable/Disable facility, Data/Time/Password configuration, One Man walk test facility, CE certificate, Battery Charging/Battery Internal Resistance Monitoring, Aux output facility, On board memory lock switch to prevent unauthorized panel configuration changes. Configurable delays to output, with timer to fire indication, Construction Powder coated Cold Rolled STEEL 1.2mm thick, Operating Temperature 0 to 49°C, Relative Humidity 5% to 95% Non-Condensing, Control Keys: Silence Buzzer, Silence/Resound Alarm, Reset, Evaluate, Accept delay: Indicators: Fault, NAC Fault, Earth Fault, Fire, Power, System Fault. Make: Siemens Cerberus / Honeywell Morley / Bosch FPA / GST 200 (EN) | 1 | Each | 44,300 ₹44,300 |
| 4.00 | Supply, Installation, Testing and Commissioning of Conventional Photoelectric Smoke Detector with the features of Operating Voltage Range 8 to 30VDC (Nominal 12/24VDC), Non-Polarised Typical Standby Current @ 250 C 30 µA @ 24VDC, Maximum Alarm Current (LED On) 80mA @ 24VDC (Limited by panel), Application Temperature Range -300 C to plus 700C, Humidity 5 to 95% Relative Humidity (non condensing, Max Wire Gauge for Terminals 0.75mm2 to 2.5mm2, Color White LC-FY2605, Material ABS15A1. Low profile design, Low current draw, Designed with a tamper-resistant feature, Detector base included in the detector packaging, Wide operating voltage 8 to 30VDC, Bi-colour LED detector status indicator providing 360°visibility, Automatic drift compensation, In-built magnet for sensor magnet test at the field, Tested to EN54 – 7:2000, CE Certified (EN IEC 61000-6-3:2021), (EN 50130-4:2011 plus A1)
Make: Siemens Cerberus / Honeywell Morley / Bosch FPA / GST 200 (EN) | 103 | Each | 1,790 ₹1.8 L |
| 5.00 | Supply, Installation, Testing and Commissioning of MCP Indoor Manual Call Point with the features of Unique ‘Plug and Play’ installation concept, Total ‘Flex-Ability’ in the choice of operating element, Anti-Tamper facility, Enhanced aesthetics, Fully approved to the latest standards.
Make: Siemens Cerberus / Honeywell Morley / Bosch FPA / GST 200 (EN) | 6 | Each | 2,360 ₹14,160 |
| 6.00 | Supply, Installation, Testing and Commissioning of Selectable Output Horns, Strobes with the features of 12 and 24V operation, ?High and low volume settings, ?Temporal and non-temporal tones, ?Mounts to single gang back box, ?Compatible with MDLsunc module, Mechanically and electrically compatible with PA400 series, Mini-Alert TM sounders. Easy to use rotary dials for selection of candela and horn ?settings, Built in synchronization feature keeps strobes in sync for up to ?30 minutes, ?Strobes Listed to UL1638: Horns Listed to UL464, Horn settings on the horn strobe model include high and low ?volume, continuous or temporal 3 tone, ?Round trim ring available for ceiling mount applications, ?Universal Fire symbol is language independent, Trim plate allows mini horn to mount to a variety of backboxes and fit aesthetically with the horn strobe and strobe.
Make: Siemens Cerberus / Honeywell Morley / Bosch FPA / GST 200 (EN) | 6 | Each | 4,550 ₹27,300 |
| 7.00 | Supply, Installation, Testing and Commissioning of Public Address System in Rack: consisting of the following: - i) 120W Amplifier to suitable size 01No. ii) Selector and all facility for announcement of different floor - 01Set iii) Gooseneck paging microphone for public address system = 01 No
Make: Siemens Cerberus / Honeywell Morley / Bosch FPA / GST 200 (EN) | 1 | Each | 79,000 ₹79,000 |
| 8.00 | Supply, Installation, Testing and Commissioning of minimum 1000 Mtr. Range Siren provided at the roof of the building with separate power supply, relay etc. with all accessories required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge. Make: National / Kheraj | 1 | Each | 5,900 ₹5,900 |
Tender Value
₹6.1 L
EMD Value
₹12,260
Closing Date
26 Dec 2025, 5:00 pmClosed
AMIT GOYAL
ED - Rohtak
Provision for PVC Pipe, System Sensor Fire Alarm Control Panel, Conventional Photoelectric Smoke Detector, MCP Indoor Manual Call Point, Selectable Output Horns, Range Siren, Public Address System, Ceiling Mount, 2 Core Audio Wire, Glow Type Exit Sig
2025_HRY_491526_1
20255EF9B290 3B93 410E AF05 23F5AB84D2AD667BAR
Open Tender
Electrical Works
60 days
KANONDA
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹12,260
Yes
9 Feb 2026
18 Dec 2025
29 Dec 2025
18 Dec 2025
26 Dec 2025
18 Dec 2025
Amount
HSR Items
[23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
NS Items
Supply, Installation, Testing and Commissioning of System Sensor Fire Alarm Control Panel 6 zone with the features of Support 16 x 2 Char LCD Display, Aesthetically designed Front Facia / LED`s, Individual Zone Isolation, Event Logging, Earth Fault Monitoring, Aux output facility, On board memory lock switch to prevent unauthorized panel configuration changes, Mechanical Keylock, Monitored NAC and Zone Circuit for Open / Short / Faults, Fire, Fault, Configurable Relay, Customizable text inserts, Input for remote reset/ evacuate/alert/fire, Lamp Test Facility, Fire, Fault, Configurable Relay, Certified for Safety standard. IEC 62368-1:2018, NAC Enable/Disable facility, Data/Time/Password configuration, One Man walk test facility, CE certificate, Battery Charging/Battery Internal Resistance Monitoring, Aux output facility, On board memory lock switch to prevent unauthorized panel configuration changes. Configurable delays to output, with timer to fire indication, Construction Powder coated Cold Rolled STEEL 1.2mm thick, Operating Temperature 0 to 49°C, Relative Humidity 5% to 95% Non-Condensing, Control Keys: Silence Buzzer, Silence/Resound Alarm, Reset, Evaluate, Accept delay: Indicators: Fault, NAC Fault, Earth Fault, Fire, Power, System Fault. Make: Siemens Cerberus / Honeywell Morley / Bosch FPA / GST 200 (EN)
Supply, Installation, Testing and Commissioning of Conventional Photoelectric Smoke Detector with the features of Operating Voltage Range 8 to 30VDC (Nominal 12/24VDC), Non-Polarised Typical Standby Current @ 250 C 30 µA @ 24VDC, Maximum Alarm Current (LED On) 80mA @ 24VDC (Limited by panel), Application Temperature Range -300 C to plus 700C, Humidity 5 to 95% Relative Humidity (non condensing, Max Wire Gauge for Terminals 0.75mm2 to 2.5mm2, Color White LC-FY2605, Material ABS15A1. Low profile design, Low current draw, Designed with a tamper-resistant feature, Detector base included in the detector packaging, Wide operating voltage 8 to 30VDC, Bi-colour LED detector status indicator providing 360°visibility, Automatic drift compensation, In-built magnet for sensor magnet test at the field, Tested to EN54 – 7:2000, CE Certified (EN IEC 61000-6-3:2021), (EN 50130-4:2011 plus A1) Make: Siemens Cerberus / Honeywell Morley / Bosch FPA / GST 200 (EN)
Supply, Installation, Testing and Commissioning of MCP Indoor Manual Call Point with the features of Unique ‘Plug and Play’ installation concept, Total ‘Flex-Ability’ in the choice of operating element, Anti-Tamper facility, Enhanced aesthetics, Fully approved to the latest standards. Make: Siemens Cerberus / Honeywell Morley / Bosch FPA / GST 200 (EN)
Supply, Installation, Testing and Commissioning of minimum 1000 Mtr. Range Siren provided at the roof of the building with separate power supply, relay etc. with all accessories required to complete the job in all respect upto the entire satisfaction of Engineer-in-Charge. Make: National / Kheraj
Supply, Installation, Testing and Commissioning of Celling Mount / wall mount Speaker with Plastic Mount or without mount as per site requirement for operation 6 Watts Make: Honeywell / Ahuja / Henrich
Supply Installation Testing and Commissioning of battery backup for controllers (2 KVA UPS offline with 1 hour’s backup) and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. Make APC / Liebert / Emerson / Microtek
Supply, Installation, Testing and Commissioning of 2 Core Audio Wire for Speakers complete in all respect upto the entire satisfaction of the incharge of the work. Make:- Finolex / Polycab / Havells
Supply Installation Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of work Make : Glolite / Pearl / Omex
Supply, Installation, Testing and Commissioning of 17 U Standard rack to place all AV equipment Make Valrack / Comrack / Hive Networks (HN)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
BOQ_569849.xls
BOQ • 0.29 MB
AD0140113.pdf
Additional Documents • 1.51 MB
OT0140113.pdf
Other Document • 0.79 MB
Download all tender documents and submit your bid