Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-Finance | L1 | Accepted-Finance LOWER AMOUNT QUOTED | |
| 2 | L2₹7.1 L+₹42,000 (6.27%)Rejected-Finance | L2 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 3 | L3₹7.2 L+₹45,550 (6.80%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L3 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 4 | L4₹7.6 L+₹86,400 (12.9%)Rejected-Finance 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance HIGHER AMOUNT QUOTED | |
| 5 | L5₹9.8 L+₹3.1 L (46.3%)Rejected-Finance 2645 SAYAROLI BAZAR NASIRABAD RAJ 305601 | NASIRABAD | AJMER | RAJASTHAN | 305601 | L5 | Rejected-Finance HIGHER AMOUNT QUOTED |
Tender Value
Refer Docs
EMD Value
₹19,800
Closing Date
16 Feb 2021, 6:00 pmClosed
AGE I UDAIPUR
ASST. GARRISON ENGINEER (I) EKLINGGARH CANTT, UDAIPUR (RAJ.) - 313001
REPAIR/MAINT OF DESERT COOLER, AIR CONDITIONER, DEEP FREEZER AND WATER COOLER
2021_MES_417026_1
8591/E8/AGE I UDAIPUR
Open Tender
Civil Works
Item Rate
120 days
ARMY AREA MOUNT ABU
AS PER TENDER DOCUMENTS
5 documents required · 5 mandatory
₹500
AGE I UDAIPUR
₹19,800
Yes
18 Feb 2021
29 Jan 2021
18 Feb 2021
29 Jan 2021
16 Feb 2021
2 Feb 2021
Amount
Supply and replace three pin metal top for AC box .
Material & Labour for welding / brazing steel / copper vessel ( storage water tank of cap 25 / 50 ltrs ) including pressurising and leakage testing complete all as directed.
Material & Labour for Repairs to hot water tank capacity 750 Ltrs with properly sealing the joint complete with removing and replacement of the insulation i.e glass wool, chicken mesh, aluminium sheet, reconnect with solar panel and testing all as specified and directed by Engr-in-Charge.
Material & Labour for Repairs to hot water tank capacity 1000 Ltrs with properly sealing the joint complete with removing and replacement of the insulation i.e glass wool, chicken mesh, aluminium sheet, reconnect with solar panel and testing all as specified and directed by Engr-in-Charge.
Taking down old unsv GI pipe and supply and laying new GI pipe med grade incl all GI pipe fittings, on wall/floor of following sizes :-
(a) 15 mm dia
(b) 20 mm dia
(c) 25 mm dia
Supply & Fixing in repair for providing 50mm thick insulation with glass wool, chicken mesh & aluminium sheet (26 guage) thick on existing GI pipe for solar heating system of following sizes of GI pipe :-
(a) 20 mm dia
(b) 25 mm dia
Taking out old unserviceable valve and Supply & Fixing Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe (Make-Zoloto/Leader/Techno) and fixed of following sizes :-
(a) 20 mm dia
(b) 25 mm dia
Taking down & Supply and fixing of Copper Absorber of following specification : No. of Fins & Tubes: 09 Nos. Absorber Area : 2 Sq Mtr Copper Riser : Dia. 12.7 mm x 0.45 mm thk Copper Absorber sheet : 0.10 thk 2 No. Copper Header : Dia. 25.4 mm x 0.60 mm thk Header Inlet / Outlet : Brass Flange With necessary asbestos gasket & rubber grommet
Taking down and Supply & Fixing rubber U-channel for solar collector, complete as per required at site.
Taking down and Supply & Fixing inter connection GI tee, of 25 mm bore, complete as per required at site.
Taking down solar glass panel complete and Supply & Fixing new solar glasspanel having transmitivity 85% complete with copper tube all as specified and directed.
Material & Labour for flushing, pressurising the system , leakage testing vacuumisation and gas charging and replacement of filter/stainer including testing at site for refrigerator of cap 210-310 Ltrs.
Material & Labour for flushing, pressurising the system , leakage testing vacuumisation and gas charging and replacement of filter/stainer including testing at site for deep freezer of cap 320 ltrs.
Repair of whirlpool refrigerator by addition alteration in electronic circuit of frost free refrigerator and testing after completion all as directed
Supply and replace fan suitable for frost free double door refrigerator MAKE :WHIRLPOOL
Supply and replace START RELAY for refrigerator of any make model as per existing.
Supply and replace OVERLOAD PROTECTOR for refrigerator of any make model as per existing.
Supply and replace HERMATIC SEALED UNIT suitable for refrigerator of cap 286/310 ltrs. MAKE :WHIRLPOOL/Techumsha
Supply and replace THERMOSTAT suitable for refrigerator MAKE:WHIRLPOOL.
Taking down of window/split type A/C, washing and cleaning of cooling coil, condenser with caustic soda. Replacement of air filter, oiling of fan motor, checking, testing and refixing the same after replacing the air filter at site.
Material & Labour for flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropriate pressure including testing at site for window type AC cap 1.5 ton.
Material & Labour for flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropriate pressure including testing at site for split type AC cap 1.5/2.0 ton.
Supply and replace HERMATIC SEALED UNIT suitable for window type AC, flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropriate pressure including testing at site. MAKE : Techumsha or approved by EIC
Supply and replace HERMATIC SEALED UNIT suitable for deep freezer/ Chiller RO Aquapura, flushing, pressurising the system, leakage testing vacuumisation and gas charging at appropriate pressure including testing at site. MAKE : Techumsha or approved by EIC
Supply and replace condenser fan motor suitable for deep freezer cap. 320 Ltr Make voltas.
Supply and replace running capacitor 36 mfd suitable for window type AC cap 1.5 ton.
Supply and replace starting capacitor 60 /80 mfd suitable for window type AC cap 1.5 ton.
Supply and replace THERMOSTATE suitable for window type AC cap 1.5 ton of MAKE : indfoss /denfoss.
Supply and replace RELAY WITH OVERLOAD suitable for window type AC cap 1.5 ton
Supply and replace BLOWER FAN MOTOR 1/8 HP suitable for window type AC cap 1.5 ton
Supply and replace of universal PCB & remote for window/split type AC and testing
Supply and replace SPS candle for chiller cum RO unit make : Aquapura
Supply and replace carbon candle for chiller cum RO unit make : Aquapura
Repair of solar panel structure by scraping,smootning surface and painting two coat of rubber paint over angles frame structure of approved paint.
Taking down old U/S water heater & deposite to MES store and Supply & fix Water heater storage type, electric, capacity 25 litres 5 star rating. (Make : Bajaj/Crompton/V-Guard)
boon construction company
M/s Shiv Builder and Suppliers
M/S Balkishan Panwar Construction
shri balaji trading corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .