GE PULGAON
GE PULGAON CAD PULGAON 442303
REPAIR/ REPLACEMENT OF UPGRADATION ELECTRICAL DISTRIBUTION INFRASTRUCTURE AT CAD PULGAON
2026_MES_798382_1
8425/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE PULGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE PULGAON
₹48,000
Yes
12 Nov 2026
12 Nov 2026
5 Dec 2026
12 Nov 2026
3 Dec 2026
26 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down the existing LT ACSR conductors from LT poles The conductors shall be properly coiled, bundled. Note: Existing street-light fittings, including brackets, shall be carefully taken down before dismantling the ACSR conductors to avoid damage. After removal of the conductors and associated fittings, the street lights and brackets shall be refixed at the appropriate height, as directed by the Engineer-in-Charge, complete in all respects. | 2.5 | Per Qtl | - | - |
| 2 | Dismantling and taking down the existing earth wire/guard wire from service feeders or distributor spans, including loosening and removing all clamps, binding wires and associated fittings, coiling the wire , complete as specified and as directed by the Engineer-in-Charge | 1 | Per Qtl | - | - |
| 3 | Dismantling and taking down existing cross-arms made of M.S. channels or angle sections, including removal of associated clamps, nuts, bolts and fittings, lowering the dismantled materials safely complete as specified and as directed by the Engineer-in-Charge. | 3.5 | Per Qtl | - | - |
| 4 | Dismantling and taking down existing insulators of any type, size or rating from LT overhead lines, including removal of associated binding wires, pins and fittings, lowering carefully to prevent damage, stacking the dismantled materials neatly , complete as specified and as directed by the Engineer-in-Charge | 105 | Each | - | - |
| 5 | Excavation in trenches by mechanical/Mannual means not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed by EIC.. | 375.41 | Cum | - | - |
| 6 | M&L for Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil. complete all as specified and as directed EIC. | 337.87 | Cum | - | - |
| 7 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed EIC. | 37.54 | Cum | - | - |
| 8 | Supply and fixing of 50 mm dia Double Wall Corrugated High Density Polyethylene (HDPE) pipe, conforming to IS 14930 (Part-2):2001, complete as required.The pipe shall be laid in trenches/floors or fixed along walls/poles for protection of electrical cables, including providing and fixing of necessary fittings such as bends, couplers, sockets, end caps and other accessories.The work includes cutting, jointing, proper alignment and installation, ensuring smooth passage and mechanical protection of cables, the HDPE pipe shall be double wall (outer corrugated and inner smooth), heavy duty, suitable for underground cable protection, and shall have adequate ring stiffness and impact resistance for road crossing and buried applications. All joints shall be properly sealed to prevent ingress of water and dust.complete in all respects as specified and as directed by the Engineer-in-Charge.. | 1,422 | Rm | - | - |
| 9 | Supply, laying & testing of 1.1 kV grade, heavy-duty, LT power cable with aluminium conductors, XLPE insulation, PVC inner sheath, galvanised steel strip or wire armouring, and PVC outer sheath, 16 sq. mm, 2-core, suitable for installation in trenches and along poles or walls, complete as specified and as directed by the Engineer-in-Charge.Note: Excavation and earthwork, protective pipes, cable clamps and cable joints shall be measured and paid for separately under the respective items. | 240 | Rm | - | - |
| 10 | Supply, laying & testing of 1.1 kV grade, heavy-duty LT power cable with aluminium conductors, XLPE insulation, PVC inner sheath, galvanised steel strip or wire armouring, and PVC outer sheath, 25 sq. mm, 4-core, suitable for installation in trenches and along poles or walls, complete as specified and as directed by the Engineer-in-Charge.Note: Excavation and earthwork, protective pipes, cable clamps and cable joints shall be measured and paid for separately under the respective items | 1,340 | Rm | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_895628.xls
BOQ • 0.37 MB
Tenderdocuments8425.pdf
Tender Documents • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .