| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance | -14.99% | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L1₹1.6 CrAdmitted-Finance | -14.99% | ₹1.6 Cr | L1 | Admitted-Finance |
| 3 | L1₹1.6 CrAdmitted-Finance CLASS 1 CONTRACTOR OPP 8895 14 0000 | -14.99% | ₹1.6 Cr | L1 | Admitted-Finance |
| 4 | L1₹1.6 CrAdmitted-Finance | -14.99% | ₹1.6 Cr | L1 | Admitted-Finance |
| 5 | L1₹1.6 CrAdmitted-Finance | -14.99% | ₹1.6 Cr | L1 | Admitted-Finance |
Tender Value
₹1.9 Cr
EMD Value
₹1.9 L
Closing Date
17 Dec 2025, 5:00 pmClosed
CCE Dhenkanal R and B Circle Dhenkanal
CCE Dhenkanal R and B Circle Dhenkanal
Construction of New PWD IB Balijhari at Narasinghpur Block in the district of Cuttack for the year 2025-26
2025_EICCL_122538_1
CCE DKL R and B/11-2025-26
Open Tender
Civil Works - Buildings
180 days
Choudwar
Please refer tender documents
3 documents required · 3 mandatory
₹10,000
₹1.9 L
Yes
20 Jan 2026
4 Dec 2025
18 Dec 2025
4 Dec 2025
17 Dec 2025
4 Dec 2025
1 TR to 3 TR high wall split A.C
FRAME WORK
Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job.
DRAIN PIPING
Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job.
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge.
25mm nom. Dia pipe
Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.
Construction of granular sub-base by providing Grading-VI Material as per table 400-2, mixing in a mechanical mix plant at OMC,carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 .
Providing, fixing &fitting of 80mm thick cement concrete interlocking paver block of M-30 grade and approved make,variety,colour & size made by block making machine with strong vibratory compaction of approved design and shape,laid in required colour and pattern over 50mm thick compacted bed of coarese sand, filling the joints with fine sand etc.including cost,conveyance,royality,of all matrials,labour T&P etc.complete in all respect as per direction of the engineer-in-charge.
Providing and laying at near ground level kerb stone of M-30 graded cement concrete in position to the required line, level and curveture, jointed with cement mortar 1:3 including making joints with or with out groove( thickness of joints except at sharp curve shall not to more than 5mm) including making drainage poening wherever required complete etc. as per direction of Engineer-in-charge. (precast C.C kerb stone shall be approved by Engineer-in-charge)
Loosening levelling & compacting original ground suppourting embankment to facilitate a placement of 1st layer of embankment up to a depth of 150mm mixed with water at OMC & then and then compacted by rolling as per Clause 300.20 for embankment construction as per Clause No- 305.3.4 of MoRTH specifiction.
Base Footing
Plinth beam
Column superstructure
Ground Floor
First floor
Second floor
Floor Beam
Ground Floor
First floor
Second floor
Lintel band
Ground Floor
First floor
Second floor
Roof slab
Ground Floor
First floor
Second floor
Chajja
Ground Floor
First floor
Second floor
Stair case
Ground Floor
Second Floor
Point
Supplying,fitting & fixing of 750mm dia razor wire concertina coil with 6mtr equivalent to 50 spiral lenghth clipped with two no of straight the razor fixing "U" shape M.S Angle of sizes 50x50x6mm including all conveyance labour T&P etc
RCC work of M-20 grade in the following Structural building works using 20mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including mixing hoisting lowering laying compacting concrete using concrete mixer, vibrator watering and curing for four weeks centering and shuttering and finishing the exposed surfaces smooth as per relevant clauses of section 1700 of MORT&H specification for Road & Bridge works (4th Revision) including hire and running charges of all machineries including cost, conveyance, royalty and taxes of all materials and labour with T&P required for the work etc. complete as per drawing and Technical Specification and as directed by the Engineer-in- Charge.(Excluding cost of reinforcement & binding wires to be used in the work)
Drain Base Slab
Drain Side wall
Drain Cover Slab
Earth work excavation in foundation trenches in all kind of soil including dressing and leveling the bed up to required depth and depositing the excavated materials at places away from work site within 50mtr initial lead and 1.5mtr initial lifts T&P shoring shuttering dewatering if required etc. complete as per direction of the Engineer-in-charge.
Ground Floor
First floor
Second floor
Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.
Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Supplying filling in foundation and plinth with sand in layers not exceeding 150mm thick including watering, ramming including cost, conveyance, royalty and taxes of all materials, all labour T&P required for the work etc. complete (measurement will be taken on finished compacted section only) etc. complete as per direction of the Engineer-in-charge.
Ground Floor
First floor
Second floor
Cement concrete of propertion (1:3:6) in foundation and floors using 40mm nominal size clean hard black cursher broken granite metal of approved quality from approved quarry including lowering laying concrete in layers not exceeding 15cm thick to the required level ramming watering curing centering & shuttering etc. complete including cost conveyance royalty taxes of all materials and all labour T&P required for the work etc. complete as per direction of the Engineer-in-charge.
Ground Floor
First floor
Second floor
RCC work of M-25 grade in the following Structural building works using 20mm down graded hard black granite Crusher broken aggregates of approved quality from approved quarry including mixing hoisting lowering laying compacting concrete using concrete mixer, vibrator watering and curing for four weeks centering and shuttering and finishing the exposed surfaces smooth as per relevant clauses of section 1700 of MORT&H specification for Road & Bridge works (4th Revision) including hire and running charges of all machineries including cost, conveyance, royalty and taxes of all materials and labour with T&P required for the work etc. complete as per drawing and Technical Specification and as directed by the Engineer-in- Charge.(Excluding cost of reinforcement & binding wires to be used in the work)
Ground Floor
First floor
Second floor
Labour charges for straightening the coiled or bend up M.S. rod / HYSD bars confirming to Gr. Fe-500, cutting bending binding lapping placing welding etc. (Confirming to ISI specification) and jointing if necessary by lapping and tying the grills and placing in position as required for RCC work as per approved design hoisting lowering and laying in position including cost conveyance & taxes of M.S. rod / tor steel (Primary Producer like- SAIL/RINL/TATA/ JINDALSTEEL/ SHYAM STEEL) make) and binding wire of 18 to 20 gauge (as approved by the deptt.) weight of over lapping, couping, welded joints, spacer bar, chair, stage, hanger and binding wires shall not be considered for payment at all. Standard co-efficient of different size of the steel shall be considered. Welding & lapping should be confirming to relevant clause of IRC 1987 in all floors.
Ground Floor
First Floor
Fly ash brick masonry in cement mortar (1:6) in Foundation and plinth using bricks of “25cm x 12cm x 8cm" size having a crushing strength of not less than 75 Kg. Per Sq. Cm. including immersing in water till saturation before use, Including splays cutting, circular molding, chamfering and corbelling and all similar type of operations with all necessary projections watering and curing etc. complete including cost and conveyance royalty and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors as per drawing and Technical specification and as directed by the Engineer-in-Charge.
Ground Floor
First Floor
Supplying, fitting and fixing Granaite tile in floors of approved make conformaing to IS:13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction of E.I.C.
Ground Floor
First Floor
Fixing tiles in dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete.
Ground Floor
First Floor
Supplying, fitting & fixing of Industrial vitrified tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with epoxy gouut of of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge
Ground Floor
Fly Ash brick masonary using Fly Ash brick of size 25cmx12cmx8cm having crushing strength not less than 75kg/cm2 in cement mortar of (1:6) after immersing the bricks for six hours in water before use in superstructure including splays cutting circular moulding corbelling champhering and similar such type of work watering and curing including cost conveyance royalty taxes of all materials and cost of all labour with T&P required for the work in all floors etc. complete as per direction of the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Providing 16mm thick cement plaster in cement mortar (1:6) finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Providing 12mm thick cement plaster in cement mortar (1:6) finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Providing 6mm thick cement plaster in cement mortar (1:4) finished smooth to brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smo
Ground Floor
First Floor
Second Floor
oth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Providing and fixing 12.5mm thk. Gypsum board false ceiling consisting of G.I. perimeter channels of size 0.55 thick, screw fixed to brickwall/partition with the help of nylon sleeves and screws, at 610mm centres. The suspending G.l.intermediate channels of size 45mm, 0.9mm thick with two flanges of 15mm each from the soffite at 1220mm centres with ceiling angle of width 25mm x 10mm x 0.55 thick fixed to soffite with G.I. cleat and steel expansion fastners at every 610mm c/c. 12.5mm tapered edge Gypsum board is then screw fixed to ceiling section with 25mm drywall screws The boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edge of the boards with jointing compound & joint paper tape as per approved design and specificatin etc.fitted and fixed in position etc. with cost, conveyance, taxes of all materials, labour, T&P required for complete in all respect.
Ground Floor
First Floor
Providing and fixing ISI marked 35 mm thick flush door shutters confonning to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete.
Ground Floor
First Floor
Supplying, fitting, fixing of Vitrified Tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mmx600mm Colour/printed series of approved make in floors on 20mm thick bed of cement mortar (1:4) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, taxes, labour, labour cess T&P erc. required for the work complete in all respect as per direction of the Engineer-in-charge.
Ground Floor
First Floor
Second Floor
Providing and laying of coloured/printed Vitrified Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.
Ground floor
first floor
Second floor
Supplying, fitting and fixing 100mm dia PVC rain water outlet pipe including cost convence, labour, T&P require for the work in all respect as per specification and direction of Engineer-in-charge. (Supreme/Ashirvad/Oriplast)
Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50 mm dia of 2 mm thick circular pipe with Balustrade of size 32 mm x 32mm x 2mm @ 0.90 mtr C/C and stainless aquare pipe bracing of size case as per approved design and specification, buffing, polishing etc. with the cost, conveyance taxses of all material, cost of all labour etc. complete in all respect as per drawing and Technical Specification and as directed by the Engineer-in-Charge.
Ground floor
First floor
P.C.C.M-20 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete
Ground Floor
Dismantling and removing R.C.C. columns, beams, slab, staircase, landing and lintels including stacking the useful materials for reuse and removing the debris within 50m lead. Per 1 cum
Dismantling brick or stone masonry in lime or cement mortar upto 3mtr height including stacking the useful materials for reuse and removing the debris within 50m lead. Per 1 cum
Dismantling and removing cement concrete including stacking the useful materials for reuse and removing the debris within 50m lead.Per 1 cum
20mm dia CPVC pipe
25mm dia CPVC pipe
25mm UPVC ASTM Pipe in Ground floor
32 mm dia UPVC ASTM pipe
First floor
20mm dia CPVC pipe
25mm dia CPVC pipe
25mm UPVC ASTM Pipe in 1st floor
40mm diaUPVC ASTM pipe
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. 250mm thick wall
In Ground Floor
In first floor
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.
In Ground Floor
First floor
Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.
15mm dia CP Bib cock (FLR-CHR-5047N Jaquar make)
15mm dia CP 2 Way bib cock (FLR-CHR-5041N)
15mm dia long body Sink cock (Jaquar)-CON-CHR-357KN
15 mm dia CP L.B. Bib cock (CON-CHR-037KN)
15mm dia CP angle stop cock (FLR-ACR-5053N)
15mm dia C.P. wall mixture 3-in-one System (Jaquar make with provision for over head ShowerFLR-ANQ-5281N
Single Lever Basin Mixer without PopupWaste with 450mm Long Braided Hoses(As Per Cat. No: Cat. No: KUP-CHR-35011BPM of Jaquar)
32mm dia CP on Brass Bottle Trap (As per Cat. No. ALD-CHR-769L250x190 of Jaquar)
ELENA VERTICAL(Manual) JAQUAR WATER HEATER( ELM-WHT-3KWV010)
15mm dia CP piller cock (CON-CHR-021KN)
15mm dia CP flange
15mm Cp extention piece
Double coat hook (AKP-CHR- 35761P Jaquar make)
25mm brass full way valve
32mm brass full way valve
40mm brass full way valve
125mmdia C.P.grating
15mm dia CP Health faucet -jaquar make-HSH-CHR-85537))
600mm X 125mm C.P glass shelf (CAN-CHR-1171N)
25mm CP towel rail (CAN-CHR-1111N)
Shower Arm (SHA-CHR-477)
Over head shower 150 x 150 square (jaquar OHS-CHR-1605 Make)
C.P towel ring (CAN-CHR-1121NMI)
Towel Rack 600mm long with Lower Hangers, Stainless Steel AKP CHR-35781PS of jaquar
Corner shelf ACN-CHR-1173(Jaquar make)
CP soap holder (CAN-CHR-1131N)
Supplying all materials, labour, T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701--1996 including cutting holes through the tank and fixing mild steel ltubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting up to a height of 5 meters above ground level and placing the tank to the required position and providing 1st class Fly ash.Brick work in cement mortar (1:6) of 0.46mt. height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C.slab of size 1.60mt.x1.60mt. and 0.10mt. thick, R.C.C.beam of 0.25mt.x0.30mt. and 2.60mt. average length in cement concrete (1:2:4) using 12mm size h.g.chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.
2000 litre capacity water storage tanks(3 Layer) in 2nd floor-sintex make
Supplying all materials,labour,T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No.13592/1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification,testing,earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of Engineer-in-charge. (Supreme/Ashirvad/Oriplast)
110mm dia U-PVC SWR Pipe
75 mm dia U-PVC SWR Pipe
110mm dia U-PVC Door Tee
110mm dia U-PVC Plain Tee
110mm dia U-PVC Door Bend
110mm dia U-PVC Offset without ear
110mm dia U-PVC 'P' trap
110mm dia U-PVC Plain Band
110mm dia U-PVC Cowl
110mm dia U-PVC clamp
75mm dia U-PVC Door Bend.
75mm dia U-PVC Plain Bend.
110x75mm dia Reducer
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge 250mm to 375mm thick wall
Supplying all materials, labour, T&P and cutting holes in R.C.C roofs,comice etc for passing HCI Pipes/U.P.V.C Pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concre(1;2;4) includeing finishing complete so as to ma
ke it leak proof as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge a.European water closet with ‘S’ trap plain (Parrywere/Hindware/Nicer Make)
(a)EWC (Jaguar LYRIC Make -LYS-WHT-38851P180UFSM
Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge 600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make)
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps(Plaza make) capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge
550mmx400mm size wash hand basin with Pedestall ( (Jaguar LYRIC Make -LYS-WHT-38801 & 38301 )
Supply all materials and labour for fitting and fixing of following size white glazed vitreous chinaHalf Padestal wash hand basin of approved make in all floor of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4) etc. including all taxes, duties, transportation etc. all complete as per direction of EIC. (Make:JAQUAR/HINDWARE/CERA/PARRYWARE) Half pedestal basin FNS-WHT-40801 Wall Hung Basin with Fixing Accessories Size: 620x480x185 mm & FNS-WHT-40305Half pedestal with Fixing Accessoriesfor 40801
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge
Design Mirror
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. In ground floor
Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. in ground floor
Ground Floor
First floor
Supplying all materials, labour, T&P and providing cement concrete (1:2;4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C.
First floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 12mm thick CP (1:4) on bw,-In Ground floor
First floor
Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size ground floor
First floor
Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600 x 300 cm size in Ground floor
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:1.5:3) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, fly ash bricks in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI/P-trap gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Inside size 250mmx250mm
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthw
ork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inside size 760mmx760mmx460mm
Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inside size 910mmx910mmx910mm
Cost of R.C.P.C.Cover.
Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.22m dia x 2.10m deep soakway pit
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.
110mm dia u-pvc pipe alround concrete
160mm dia u-pvc pipe alround concrete
Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 80 PSS UV of size 750x570x1350mm height with water storage capacity 80 liters along with 2 nos of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all complete as per approved drawing,specification and direction of the Engineer in charge.
Sinking of 200mmx150 mm dia Tube Well by DTH Method up to 100mtr. Depth.(1nos)
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
Labour for drilling of 200mm dia & 150mm dia bore from '0' mtr. to '75' mtr.
Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
Lowering of 200mm dia GI/P.V.C/MS casing pipes 0 mtr to 45 mtrs = 1x60mtr
Cost of 200mm dia P.V.C schedule-80 pipe =1x60mtr
By DTH/Rotary Rig
Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.
1 H.P single phase submerssible pump set
DOL control panel
2.50sqmm cable
32mm dia steel short piece
Steel rope
Bore cap
32mm dia HDPE pipes
Rigid casing pipe for cable
Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site.
Supply all materials,labours,T&P and construction bore well protection chamber of the inside size 650x650x1000 height with cement concrete ( 1;3;6) using 40 mm size hard granite metal on foundation,1st class fly ash brickwork incement motar(1:3),with base cement concrete (1:2:4) useing 12 mm size h.g chips ,12 mm thick cement plaster (1:4) inside and out site ,R CC cover slab in (1:1.5:3) using 12 mm size h.g chips earthwork in excavation in all kinds of soil and refiling the cavity around the chamber including watering ,curing,convayance of all materials to worksite,payment of royalty,taxes etc all complete as per approved specification and direction of the engineer-in -charge. Bore well protection chamber.
Construction 1 nos 30 users RCC Septic tank
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
- do - with addl. Depth of 1.5 m
Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department.
Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department.
In ground floor
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Roof Slab-
For RCC wall
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in char
Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 160mx160mx160m as per P.H.D.specification and direction of the E.I.C.
Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
110mm dia U-PVC Cowl
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
Supplying all materials, labour, T&P and fitting and fixing UPVC SWR soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge.
110mm diameter U-PVC SWR pipe
110mm dia U-PVC Plain shoe bend
CONSTRUCTION OF 10000 LTR RCC SUMP 1nos
Earthwork in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge.
Initial lift
Earthwork in excavation of foundation in stonety earth mixed with gravel within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge.
1st Extra lift -
Supplying all materials, labour, T&P and providing filling sand including watering, ramming and conveyance of all materials to site.
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 40mm H.G metal including watering, curing and conveyance of all materials to site.
Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete.
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.
RCC walls
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:3) including watering,curring and conveyance of all materials to site.
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. (1no)
Supplying all materials, labour, T&P and futting and fixing 20mm dia MS/CI step iron including supply of necessary C.C(1:2:4) for fixing etc complete as per P.H.D. specification. (1no)
Supplying all materials, labour, T&P and cleaning of debries,uprooging and disposing at a safe distance all complete as per direction of the Engineer in charge
Sweeper
Group-A:
Group-B:
Group-C:
Supplying and fixing 6 Amp plug with 6 Amp switch (Modular Type) on existing board. Make:Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
Supplying and fixing including testing and commissioning of 6A modular socket outlet with 6 Amp switch including providing GI modular box with faceplate etc as required. Make:Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
1 nos 6 Amp 3-pin socket with 6 Amp switch.
2 nos 6 Amp 3-pin socket with 2 nos 6 Amp switch.
Supply, installation, testing & commissioning of 6 / 16 Amp Plug Boards consisting of a 16 Amp clip-in type modular switch with indicator and a 6/16 Amp clip-in type modular socket fixed on metallic concealed box including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge. Make:Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
Supplying, installation, testing & commissioning of 25 amp modular socket outlet on surface or in recess, on 1 Nos two module GI box with 25A Starte motor . complete as direction of Engineer-in-charge.Switch & socket: Legrand(Myirus)/schneider-Zenclo/Simens(Marq)
Wiring for circuit/ submain wiring along with earth wire of following size of FRLS heavy gauge PVC insulated copper conductor single core cable in heavy duty PVC conduit laid in surface/ recess as required. Make-Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI
2 x 1.5 sq.mm + 1 x 1.5 sq.mm(wiring)
2 x 2.5 sq.mm + 1 x 1.5 sq.mm (for Light plug circuit wiring)
2 x 4 sq.mm + 1 x 1.5 sq.mm (For power circuit)
2 x 6 sq.mm + 1 x 4 sq.mm(For SPN DB & AC POINT)
4 x 10sq.mm + 2 x 4 sq.mm (For TPN DB)
For Inverter wiring 1 X 1.5sqmm
S/F of recess/surface mounted 2'x2' 36W (595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Bajaj /Philips/Wipro /Crompton/Havells) . The luminaire must be Replacement Warranty will be 5years.
S/F of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.(Make: Bajaj /Philips/Wipro /Crompton/Havells) .The luminaire should be Replacement Warranty will be 2 years
S/F of energy efficient LED tube/ Batten light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Bajaj /Philips/Wipro /Crompton/Havells) . The luminaire should be Replacement Warranty will be 2 years .
S/F of Energy efficient surface /recess mounted square /round shape 9 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 9 watt and lumen output of 900 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.(Make: Bajaj /Philips/Wipro /Crompton/Havells) .The luminaire should be Replacement Warranty will be 2 years
S/F of surface Mounted Led bulk head Lighter comprising of 10W LED BULK HEAD LIGHTwith non integral / integral driver, 6500K color temp having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy > 120 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM
80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c connection wire, testing etc. to complete the job. (Make: Bajaj /Philips/Wipro /Crompton/Havells)
S/F of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing, High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells/Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supplying, Erection, Fixing, connection & testing of LED Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 45 W LED street light having die cast aluminium housing with IP LC Lens having lumen efficacy of 120lm/w or more (As per LM 79 report of third party NABL lab) LED street light
S/F of 40 LED GATE Light of (Make: Panasonic/LT/Havells/Philips/Wipro/Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge.
S/F of Wall mounted 9W LED Bulb with Anchor holder & all other required accessories similar to Philips (CAT No:B22) / Equivalent of Panasonic/LT/Havells/Wipro /Crompton/Bajaj. The luminaire should be Replacement Warranty will be 2 years
S/F of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make : Crompton/ Orient/ Havells/Polycab).
1200 mm sweep
Supplying and fixing5step type electronic fan regulator wISI marked including connections etc. as required. Make:Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.
MCB, DB and PANELS
Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ ABB ITUS/LK -Exora as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
6 Way(6+18) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door
Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required
Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required.
Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,230 volts,SP MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. ..
Supplying and fixing 6-32 Amps rating, 240V, C series,10KA breaking capacity, Double pole MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .
Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge.
Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.
FIRE EXTINGUISHER SYSTEM
Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket . (Make: superimax/Cese fire/Minimax)
Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. (Make: superimax/Cese fire/Minimax)
Supplying and fixing of Fire buckets ( WITHOUT SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.
Supplying and fixing of First Aid Box.
LIGHTNING PROTECTION SYSTEM
Air Terminal
Supply , Installation, Testing & commissioning of 8 mm Aluminum Round Conductor. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Connector: Fo
r T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ). (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . (Make:OBO/ABB/ DHEN).
Down conductor
Supply , Installation, Testing & commissioning of 8 mm Aluminum Round Conductor. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Ring & vertical earthing system
Supply , Installation, Testing & commissioning of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
Supply , Installation, Testing & commissioning of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of universal clamp made of SS to connect rod with flat conductor (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system (Make:OBO/ABB/ DHEN).
LT PANEL
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 25 kA with suitable breaker and Separate Aluminium Earth bus bar should be installed.Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula)
Busbar -125A AL busbar with SC rating of 25KA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
125 Amp FP Automanual Change over with other accessories as required.
Incomer feeder consisting of
Two (2) 100 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 25 KA breaking capacity as mentioned in the BOQ with Therma Magnet Based Release with Ics=100% Icu with 3 NosIndicating lamp for ON/OFF/Trip with control fuse/ MCB, 3 Nos 100A/5 A 15VA Cl 1.0 CTs, 1No - Multifunction meter (V,A,KWHr, KW, P, F) Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula)
Three(3) - Outgoing Feeders : 01 Nos for PHE Panel, 1 nos per External Lighting Feeder Panel & 01 Nos Spare each comprising of
63Amp,4p,MCB,C-CURVE Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula)
Six(6) - Outgoing Feeders :02 Nos for LDB ,2 no P+ACDB, 1 no Pump house L+PDB, 1no 6 KVA UPS & 02 nos Spares each comprising of
40Amp,4p,MCB,C-CURVE Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula)
PANEL AS ABOVE
SITC of HT Rubber mat 1m X 2m
SITC of Shock treatment chart.
Earthing
Earthing with GI earth pipe 3m long 40mm dia ISI marked including all accessories and providing masonary enclouser with cover plate having locking arrangement and watering pipe etc. with charcoal & salt as required as per the direction of Engineer-in-charge.
S/F of Copper Plate Earthing (600x600x3.15mm) 40mm dia GI PIPE heavy duty with including copper flat, excavation of earth and providing masonary work with cover plate having loccking arangement and and , charcoal, salt , funnel , tinned brass bolt, check nut and washer complete in all respect as per Direction of Engineering -in-Charge.
Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing along with cables etc as required.
Providing and fixing 8 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
Cable Supply
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
Supplying & Testing of 1.1 KV grade Aluminium XLPE armoured power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. (Make-Polycab/Gloster/Nicco)
3.5C X 50 sqmm Al
S/F of Copper Plate Earthing (600x600x3.15mm) 40mm dia GI PIPE heavy duty with including copper flat, excavation of earth and providing masonary work with cover plate having loccking arangement and and , charcoal, salt , funnel , tinned brass bolt, check nut and washer complete in all respect as per Direction of Engineering -in-Charge.
2C X 6 sqmm
Cable laying
Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
TERMINATION OF CABLES :-
Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable)
4CX 10 sqmm
Providing,fixing and laying of fallowing dia PN16 HDPE pipe 63mm(medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
6KVA UPS FOR ELV AND EMERGENCY LIGHTING
Supply, Installation, Testing & Comissioning of 6 KVA Online UPS IGBT based True Online Smart gxtmt+ Double conversion efficiency UPS and True Online Double Conversion with DSP Control Technology for High Performance with Single phase I/P & Single Phase O/P with 30 Min Back Up on 90 % Running load along MS Battery KBS Rack & Battery inter connection link of accessories for installation.with Suitable Battery Bank for 30 min back up with Sealed Maintenance Free Battery. Make: Amararaja/ Exide/ Kalorie,open type powder coated racks for Battery as per the specification complete as per direction of Engineer in charge (Make: NUMERIC / EMERSON /APC ).
AIR CONDITION SYSTEMS
Supply, Installation, Testing, Commissioning of highwall Inverter comptabilie split units (minimum 5 star) of following capacities including proper mounting arrangements and accessories, copper refregirant piping,pvc drain piping,power cable,control cable, initial charge of refrigerant, safety limit thermostat, etc complete including 5 KVA voltage st
abilizers. ( Make - Voltas/Daikin/LG/Hitachi )
AIR CONDITION SYSTEMS
1.5 TR capacity.
REFRIGRANT PIPING
Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.61 MB
DTCN_Balijhari.pdf
Tender Documents • 3.84 MB
BOQ_569211.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid